Cooling Capacity: 100 (10 kW), Cooling Method: W (Water-cooled), Pipe Thread: Rc, Option: A (w/Caster Adjuster-foot)
Cooling Capacity: 10 kW, Cooling Method: Air-cooled, Pipe Thread: Rc, Option: w/Caster Adjuster-foot and Earth Leakage Breaker
Cooling Capacity: 10 kW, Cooling Method: Air-cooled, Pipe Thread: N [NPT, (w/Rc-NPT conversion Fitting)], Option: w/Caster Adjuster-foot
Cooling Capacity: 10 kW, Cooling Method: Water-cooled, Pipe Thread: N [NPT, (w/Rc-NPT conversion Fitting)], Option: w/Caster Adjuster-foot
Cooling Capacity: 10 kW, Cooling Method: Air-cooled, Pipe Thread: Rc, Option: w/Fluid Fill Port, Manual Fill
Cooling Capacity: 10 kW, Cooling Method: Air-cooled, Pipe Thread: Rc, Option: w/Caster Adjuster-foot and w/Fluid Fill Port, Manual Fill
Cooling Capacity: 10 kW, Cooling Method: Water-cooled, Pipe Thread: Rc, Option: w/Caster Adjuster-foot
A large digital display provides a clear view of the current and set values.
If a bypass piping set has already been installed and there is a valve, close the valve according to the situation to increase the discharge pressure of the circulating fluid.
③ Check whether the pump operates and the discharge pressure rises to determine if the flow rate is low or not present at all.
A large digital display provides a clear view of the current and set values.
A large digital display provides a clear view of the current and set values.
A large digital display provides a clear view of the current and set values.
A large digital display provides a clear view of the current and set values.
A large digital display provides a clear view of the current and set values.
A large digital display provides a clear view of the current and set values.
A large digital display provides a clear view of the current and set values.
A large digital display provides a clear view of the current and set values.
A large digital display provides a clear view of the current and set values.
If the circulating fluid falls below the rated flow rate, it may cause a drop in the cooling capacity of the thermo-chiller or a decline in temperature stability.
In this case, use the bypass piping set (optional accessory) to secure the flow rate.
Note) The temperature stability is as follows: ±2.0℃ for the HRSE, ±0.5℃ for the HRS090, and ±1.0℃ HRS100/150/200.
Cooling Capacity: 150 (15 kW), Cooling Method: W (Water-cooled), Pipe Thread: N [NPT, (w/Rc-NPT conversion Fitting)], Option: ABK (w/Caster Adjuster-foot, w/Earth Leakage Breaker, and Fluid Fill Port)