MY1W63 5.4 (Max. 11) 5 (Max. 11) 5 (Max. 16.5) 8 (Max. 20) 9 (Max. 25) 13 (Max. 33) 13 (Max. 38) 5.8 5.8 6.5 8.5 10 14 14 39.5 45.5 53.5 67 83 106 129 14.6 20 24 29 35 40 52 58 58 70 88 104 128 152 7 10 12 14 17 20 26 6 6 7 12 12 15 15 8-12-21 22 Series MY1W Side Support Side support A MY-SA 2-G 2-H E E F A B C D Side support B MY-SB 2-J 2-H C D A B (mm) A B C 15 25 35 45 E F G D H J M4
10 12 14 17 20 26 8-12-21 22 Series MY1W Side Support Side support A MY-SA 2-G 2-H E E F A B C D Side support B MY-SB 2-J Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 2-H C D A B (mm) A B C 15 25 35 45 E F G D H J M4 x 0.7 M5 x 0.8 M6 x 1 M8 x 1.25 Applicable
Load weight Allowable moment MY2H/m3 MY2H/M3 MY2H/M1 MY2H/M2 60 50 60 50 60 50 60 50 40 40 30 30 30 30 20 20 20 20 Load weight kg Moment Nm Moment Nm Moment Nm MY2H40 MY2H40 MY2H40 MY2H40 10 10 10 10 MY2H25 MY2H25 MY2H25 MY2H25 5 5 5 5 4 4 4 4 3 3 3 3 MY2H16 2 2 2 2 0.2 MY2H16 MY2H16 MY2H16 1 1 1 100 200 300 400500 1000 1500 1 100 200 300400 500 1000 1500 100 200 300 400500 1000 1500 100
20 MY2HT25 MY2HT25 20 MY3A MY3B MY2HT16 10 10 10 MY3M MY2HT16 MY2HT16 8 8 8 5 5 5 100 200 300 400500 1000 1500 100 200 300 400500 1000 1500 100 200 300 400 500 1000 1500 Piston speed mm/s Piston speed mm/s Piston speed mm/s Load Mass/MY2HT (Double axis) MY2HT/m1 MY2HT/m2 MY2HT/m3 80 80 80 50 50 50 30 30 30 20 20 20 MY2HT40 MY2HT40 MY2HT40 Load mass kg Load mass kg Load mass kg 10 10 10 MY2HT25
Load Weight Allowable Moment MY2H/m3 MY2H/M3 MY2H/M1 MY2H/M2 60 50 60 50 60 50 60 50 40 40 30 30 30 30 20 20 20 20 Load weight kg Moment Nm Moment Nm Moment Nm MY2H40 MY2H40 MY2H40 MY2H40 10 10 10 10 MY2H25 MY2H25 MY2H25 MY2H25 5 5 5 5 4 4 4 4 3 3 3 3 MY2H16 2 2 2 2 0.2 MY2H16 MY2H16 MY2H16 1 1 1 100 200 300 400500 1000 1500 1 100 200 300400 500 1000 1500 100 200 300 400500 1000 1500 100
rt...i.i.1,.j,.: j..i riir',: .,,, I . .:t::;il..: li:aj;Ir:'ri.iii:r:l..::.::..l:lai,l.''.'''
MY2 H/HT MY3A MY3B MY3M Load Mass Allowable Moment MY1H/m3 MY1H/M3 MY1H/M1 MY1H/M2 q r w e t 30 40 50 50 40 30 40 50 30 40 50 30 20 20 20 20 MY1H40 MY1H32 10 10 10 MY1H40 MY1H40 MY1H32 Load mass kg MY1H32 Moment Nm Moment Nm Moment Nm 5 4 3 MY1H25 MY1H40 10 5 4 3 5 4 3 MY1H32 MY1H25 MY1H25 2 MY1H25 5 4 2 2 1 3 1 1 0.5 0.4 0.3 2 0.5 0.4 0.3 0.5 0.4 0.3 D0.2 1 0.2 0.2 0.1 -X 100 200 300 400
Load weight Allowable moment MY2H/m3 MY2H/M3 MY2H/M1 MY2H/M2 60 50 60 50 60 50 60 50 40 40 30 30 30 30 20 20 20 20 Load weight kg Moment Nm Moment Nm Moment Nm MY2H40 MY2H40 MY2H40 MY2H40 10 10 10 10 MY2H25 MY2H25 MY2H25 MY2H25 5 5 5 5 4 4 4 4 3 3 3 3 MY2H16 2 2 2 2 0.2 MY2H16 MY2H16 MY2H16 1 1 1 100 200 300 400500 1000 1500 1 100 200 300400 500 1000 1500 100 200 300 400500 1000 1500 100
With Rod Boot Bore size (mm) e f h ZZ Stroke range (mm) l 40 50 63 80 100 20 to 500 43 11.2 59 1/4 stroke 154 20 to 600 52 11.2 66 1/4 stroke 167 20 to 600 52 11.2 66 1/4 stroke 178 Dimensions of the mounting brackets are the same as those of the standard double acting single rod type.
Cooling Method: W (Water-cooled Refrigeration), Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: B (w/Earth Leakage Breaker)
Cooling Method: W (Water-cooled Refrigeration), Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: M (Applicable to Deionized Water Piping)
Thermo-chiller HRS offers convenient functions, self diagnosis and check display for easy maintenance. An angled supply port facilitates the supply of circulating fluid, even when units are stacked. A large digital display provides a clear view of the current and set values. The dustproof filter is integrated with the grill of the front panel allowing mounting and removal of the HRS filter
Cooling Capacity: 9 kW, Piping thread type: NPT (Rc-NPT conversion fitting included), Optional specifications: With earth leakage circuit breaker
Cooling Method: Water-cooled Refrigeration, Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: Applicable to Deionized Water Piping
Table 2.4-20 List of set values Set value Explanation Initial value (Default setting) Sets LOCAL mode. Sets DIO mode. Sets SERIAL mode. HRS090 Series 2.4 Setting and checking 2-15 HRX-OM-T004 Chapter 2 Contact input/output communication 2.5 Contact input signal There are two contact input signals.
Consult factory for avaitability. fttnlfibftilmm'solM 1/8', 5t32 311d' 114" 5/16' o o o c o o o 1 5 milbFffiHFmW 22 4 1 9 1 9 20 20 1 8 Plpe Reduclng Thrad Sizo Plp ThFad SEe 20 20 21 18 17 't7 | ."
Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: J (w/Automatic Fluid Fill Function)
Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: Rc, Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: J (w/Automatic Fluid Fill Function)
Cooling Method: Air-cooled Refrigeration, Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting)], Power Supply: 20 [3-phase 200 VAC (50 Hz); 3-phase 200 to 230 VAC (50/60 Hz], Option: w/Automatic Fluid Fill Function
Cooling Method: W (Water-cooled Refrigeration), Pipe Thread: N (NPT, w/Rc-NPT Conversion Fitting), Power Supply: 20 (3-phase 200 VAC, 50Hz; 3-phase 200 to 230 VAC, 60Hz), Option: J (w/Automatic Fluid Fill Function)