1.7 kW (at 60Hz); Temperature range setting: 5 to 40°C; Temperature stability: ±0.1°C; Power supply requirement: single phase 100 VAC, 50/60Hz or 115 VAC, 60Hz; Standards: CE, UL, RoHS; Circulating fluid: Tap water or 15% ethylene glycol, 30% Dowcal™100, ControXic 1642, Hexid A4, Coolflow IGE, NALCO®CCL105; SMC recommends Bypass Piping Set HRS-BP001 for Models HRS-012, HRS018, HRS024, HRS030
Cooling Capacity: 030 (Cooling Capacity: 2600/3200W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: F (G w/PT-G Conversion Fitting Set)
Cooling Capacity: 030 (Cooling Capacity: 2600/3200W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set)
Cooling Capacity: 030 (Cooling Capacity: 2600/3200W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set)
Cooling Capacity: 030 (Cooling Capacity: 2600/3200W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: Rc
Type: Thermo-Chiller, Cooling Method: Air-Cooling, Cooling Capacity: 2,600/3,200 W (50/60 Hz), Piping thread type: Rc, Optional specifications: None
Type: -, Cooling Method: -, Cooling Capacity: 2,600/3,200 W (50/60 Hz), Piping thread type: G (PT-G conversion fitting set included), Optional specifications: None
Type: -, Cooling Method: -, Cooling Capacity: 2,600/3,200 W (50/60 Hz), Piping thread type: NPT (PT-NPT conversion fitting set included), Optional specifications: None
Type: -, Cooling Method: -, Cooling Capacity: 2,600/3,200 W (50/60 Hz), Piping thread type: NPT (PT-NPT conversion fitting set included), Optional specifications: None
. 9-11 9.4.1 HRR012-A/W-10/20. 9-11 HRR Series HRX-OM-W002 Contents 9.4.2 HRR018-A/W-10/20. 9-11 9.4.3 HRR024-A/W-20. 9-12 9.4.4 HRR030-A/W-20. 9-12 9.5 Heating capacity . 9-13 9.5.1 HRR012-A/W-10-,HRR018-A/W-10-. 9-13 9.5.2 HRR012-A/W-20,HRR018-A/W-20 . 9-13 9.5.3 HRR024-A/W-20,HRR030-A/W-20 . 9-13 9.6 Pump capacity. 9-14 9.6.1 HRR012/018/024/030-A/W. 9-14 9.6.2 HRR012/018-A/W-10-T/MT .
MGC series 20 to 50 MGC Series (mm) C port SZ + Stroke B Cushion valve (Width across flats WH) Front mounting flange Bore size (mm) GC GD SA SB W 1 W 2 A, B port A port W 2 W 1 A 20 25 32 40 50 30 30 21 9 50 87 30 30 C port D port 21 9 50 87 B port W 2 W 1 10 A' 25 30 23 9 52 91 20 20 24 8 59 99 Cushion valve (Width across flats WH) D port ZZ + Stroke A + Stroke B SB + Stroke B SA + Stroke
--20, HRS024--20 . 9-11 9.6 Pump capacity . 9-12 9.6.1 HRS012--10-(BJM), HRS018--10-(BJM) . 9-12 9.6.2 HRS012--20-(BGJM), HRS018--20-(BGJM), HRS024--20-(BGJM) . 9-12 9.6.3 HRS012--10-T, HRS018--10-T, HRS012--10-MT, HRS018--10-MT . 9-13 9.6.4 HRS012--20-T, HRS018--20-T, HRS024--20-T . 9-13 9.6.5 HRS012--20-MT, HRS018--20-MT, HRS024--20-MT . 9-14 9.7 Required facility water flow (for water-cooled
024 030 HRR -W HRR010-W-20 30 20 Facility water flow rate [L/min] Facility water flow rate [L/min] HRR030-W 25 15 HRR024-W 20 15 10 10 HRR018-W 5 5 HRR012-W 0 0 0 10 20 30 40 0 10 20 30 40 50 Facility water inlet temperature [C] Facility water inlet temperature [C] * This is the required facility water flow rate at the circulating fluid rated flow and the cooling capacity listed in the
HRR050-A-20/40.9-10 HRR Series HRX-OM-X071 Contents 9.3.2 HRR050-W-20/40. 9-10 9.4 Cooling capacity . 9-11 9.4.1 HRR050-A-20. 9-11 9.4.2 HRR050-W-20. 9-11 9.4.3 HRR050-A-40. 9-12 9.4.4 HRR050-W-40. 9-12 9.5 Heating capacity . 9-13 9.5.1 HRR050-A/W-20. 9-13 9.5.2 HRR050-A/W-40. 9-13 9.6 Pump capacity. 9-14 9.6.1 HRR050-A/W-20. 9-14 9.6.2 HRR050-A/W-40. 9-14 9.7 Required facility water flow
Contents 9.4 Cooling capacity . 9-9 9.4.1 HRR010-A -10. 9-9 9.4.2 HRR010-W-10. 9-9 9.4.3 HRR010-A -20. 9-10 9.4.4 HRR010-W-20. 9-10 9.5 Heating capacity . 9-11 9.5.1 HRR010-A-10. 9-11 9.5.2 HRR010-W-10. 9-11 9.5.3 HRR010-A-20. 9-12 9.5.4 HRR010-W-20. 9-12 9.6 Pump capacity. 9-13 9.6.1 HRR010-A/W-10 . 9-13 9.6.2 HRR010-A/W-10-T1 . 9-13 9.7 Required facility water flow (for water-cooled type
C Port W W B port C Port D port A port D port 30 20 172 87 35 48 9 21 30 25 177 87 40 48 9 21 30 32 183 91 40 50 9 23 20 40 208 99 50 57 8 24 20 50 241 117 58 64 12 28 20 63 241 117 58 64 12 28 H SA + Stroke SB + Stroke Please contact SMC for long stroke (301 mm or more) since SA-dimensions and ZZ-dimensions are different from those in the above table.
377 283 10 8 23 17 40 30 63 47 98 72 161 121 251 188 50 37 113 84 201 150 314 235 490 358 804 603 1,256 942 8 Stud Bolt Part No. 12 Bore size (mm) Part no. 16 8 MT-S8 12 MT-S12 20 16 MT-S16 25 20 MT-S20 25 MT-S25 32 32 MT-S32 40 40 MT-S40 Replacement parts for rod end male thread.
471 OUT IN OUT IN OUT IN OUT IN OUT IN OUT IN OUT IN 50 37 113 84 201 150 314 235 490 358 804 603 1,256 942 Bore size (mm) Part no. 8 MT-S8 8 12 MT-S12 12 MT-S16 16 16 MT-S20 20 20 MT-S25 25 MT-S32 32 25 MT-S40 40 Replacement parts for rod end male thread.
Dimensions ZP2-Z002 ZP2-Z003 40 20 0.1 0.2 A A 20 0.1 0.2 40 A A 20 40 A-A A-A w q q w 11 20 9 18 90 4 x 4 90 4 x 4 4 e e 5 5 () 12 () 4 x 2.4 1.8 1.5 4 x 2.4 1.5 0.9 20 9.4 Component Parts Component Parts Part no. Description No. ZP2-Z2A ZP2-Z2B ZP2-Z2C Material PTFE FKM Aluminum alloy Note Clear anodized Part no. Description No.