An angled supply port facilitates the supply of circulating fluid, even when units are stacked. A large digital display provides a clear view of the current and set values.
Prepare an earth leakage breaker with a capacity of 10 A as listed in the HRS024 catalog. Set the current sensitivity of the earth leakage breaker to 30 mA.
Related products HRS01-A-10-, HRS01-W-10HRS050-A20-, HRS050-W-20HRS01-A-20-, HRS01-W-20HRS060-A-20, HRS050-W-20HRS024-A-20-, HRS024-W-20HRS030-A-20-, HRS030-W-20HRS040-A-20-, HRS040-W-20HRS050-A-20, HRS050-W-20HRS060-A-20, HRS050-W-202. Mounting This particle filter set includes the following parts.
Please contact us for the latest version.sales@ocaire.com, MAIN PC BOARD / HRS024-W-20, OTHERS, HRS THERMO-CHILLERS, 21, HRS - NO SIZE RATING, .00000 lb
Please contact us for the latest version.sales@ocaire.com, MAIN PC BOARD / HRS024-W-20-T, OTHERS, HRS THERMO-CHILLERS, 21, HRS - NO SIZE RATING, .00000 lb
Cooling Capacity: 024 (Cooling Capacity: 2100/2400W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: Rc, Option: MT (M + T)
Cooling Capacity: 024 (Cooling Capacity: 2100/2400W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: MT (M + T)
Cooling Capacity: 024 (Cooling Capacity: 2100/2400W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: Rc, Option: MT (M + T)
Cooling Capacity: 024 (Cooling Capacity: 2100/2400W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: F (G w/PT-G Conversion Fitting Set), Option: MT (M + T)
Cooling Capacity: 024 (Cooling Capacity: 2100/2400W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: F (G w/PT-G Conversion Fitting Set), Option: MT (M + T)
Type: -, Cooling Method: -, Cooling Capacity: 2,100/2,400 W (50/60 Hz), Piping thread type: Rc, Optional specifications: Compatible with deionized water (pure water) piping / High pump head specification
Type: -, Cooling Method: -, Cooling Capacity: 2,100/2,400 W (50/60 Hz), Piping thread type: NPT (PT-NPT conversion fitting set included), Optional specifications: Compatible with deionized water (pure water) piping / High pump head specification
Cooling Capacity: Cooling Capacity: 2100/2400W, 50/60 Hz, Cooling Method: Water-cooled Refrigeration, Thread: Rc, Option: M + T
Cooling Capacity: Cooling Capacity: 2100/2400W, 50/60 Hz, Cooling Method: Water-cooled Refrigeration, Thread: G w/PT-G Conversion Fitting Set, Option: M + T
Cooling Capacity: Cooling Capacity: 2100/2400W, 50/60 Hz, Cooling Method: Air-cooled Refrigeration, Thread: G w/PT-G Conversion Fitting Set, Option: M + T
/018/024/030-A/WFig 9-14 Pump capacity(HRR012/018/024/030-A/W-) 9.6.2 HRR012/018-A/W-10-T/MT Fig 9-15 Pump capacity(HRR012/018-A/W-10-T/MT) 9.6 Pump capacity HRR Series 9-14 HRX-OM-W002 Chapter 9 Documents 9.6.3 HRR012/018/024/030-A/W-20-T Fig 9-16 Pump capacity(HRR012/018/024/030-A/W-20-T) 9.6.4 HRR012/018/024/030-A/W-20-MT Fig 9-17 Pump capacity(HRR012/018/024/030-A/W-20-MT) HRR Series
Bore size Stroke adjustment range A B MH MT MA MI MM MK ML G L 12 to 25 MM MI 12 16 20 25 25 (15) 57.7 (64.9) 25.2 (32.4) 3.5 29 M4 x 0.7 5.5 14 5 20 8 5 to 30 28 (20) 26 (36) 58.5 (68.5) 3.5 29 M5 x 0.8 5.5 14 5 20 10 G 36 (25) 26 (38) M6 x 1 67.5 (79.5) 4.5 37 7 20 8 24 12 5 to 50 MK MT ML L MA 40 (30) 29 (39) M6 x 1 71 (81) 5 37 7 20 8 24 12 5 to 50 30.5 (40.5) 78.5 (88.5) Stroke 32 38
For HRR050-AF-20/40G thread adapter set 1 set For HRR050-AN-20/40NPT thread adapter set 1 set 1 In the case of option Z, not included.
Model number: HRR010-AN/WN-10/20 The transition connector from Rc to NPT is enclosed as an accessory. For NPT piping, be sure to use this connector. Model number: HRR010-AF/WF-10/20 The transition connector from Rc to G is enclosed as an accessory. For G piping, be sure to use this connector.