SMC Corporation of America
Elite Part Number Search
Search Results "HRS018-A-20-BGM"

Cooling Capacity: Cooling Capacity: 1700/1900W, 50/60 Hz, Cooling Method: Air-cooled Refrigeration, Thread: Rc, Option: B + T

Cooling Capacity: Cooling Capacity: 1700/1900W, 50/60 Hz, Cooling Method: Air-cooled Refrigeration, Thread: Rc, Option: High Temp Environment Specs

Cooling Capacity: Cooling Capacity: 1700/1900W, 50/60 Hz, Cooling Method: Air-cooled Refrigeration, Thread: Rc, Option: G + T

Cooling Capacity: Cooling Capacity: 1700/1900W, 50/60 Hz, Cooling Method: Air-cooled Refrigeration, Thread: Rc, Option: J + M + T

Cooling Capacity: Cooling Capacity: 1700/1900W, 50/60 Hz, Cooling Method: Air-cooled Refrigeration, Thread: Rc, Option: Automatic Water Supply Function

Cooling Capacity: Cooling Capacity: 1700/1900W, 50/60 Hz, Cooling Method: Air-cooled Refrigeration, Thread: Rc, Option: B + J

, 3.2 kW, 4.2 kW, 5.1 kW, 5.9 kW (at 60Hz); Temperature range setting: 5 to 40°C; Temperature stability: ±0.1°C; Power supply requirement: single phase 200 to 230 VAC, 50/60Hz; Standards: CE, UL, RoHS; Circulating fluid: Tap water or 15% ethylene glycol, 30% Dowcal™100, ControXic 1642, Hexid A4, Coolflow IGE, NALCO®CCL105; SMC recommends Bypass Piping Set HRS-BP001 for Models HRS-012, HRS018

capacities: 1.3 kW, 1.7 kW (at 60Hz); Temperature range setting: 5 to 40°C; Temperature stability: ±0.1°C; Power supply requirement: single phase 100 VAC, 50/60Hz or 115 VAC, 60Hz; Standards: CE, UL, RoHS; Circulating fluid: Tap water or 15% ethylene glycol, 30% Dowcal™100, ControXic 1642, Hexid A4, Coolflow IGE, NALCO®CCL105; SMC recommends Bypass Piping Set HRS-BP001 for Models HRS-012, HRS018

, 3.2 kW, 4.2 kW, 5.1 kW, 5.9 kW (at 60Hz); Temperature range setting: 5 to 40°C; Temperature stability: ±0.1°C; Power supply requirement: single phase 200 to 230 VAC, 50/60Hz; Standards: CE, UL, RoHS; Circulating fluid: Tap water or 15% ethylene glycol, 30% Dowcal™100, ControXic 1642, Hexid A4, Coolflow IGE, NALCO®CCL105; SMC recommends Bypass Piping Set HRS-BP001 for Models HRS-012, HRS018

capacities: 1.3 kW, 1.7 kW (at 60Hz); Temperature range setting: 5 to 40°C; Temperature stability: ±0.1°C; Power supply requirement: single phase 100 VAC, 50/60Hz or 115 VAC, 60Hz; Standards: CE, UL, RoHS; Circulating fluid: Tap water or 15% ethylene glycol, 30% Dowcal™100, ControXic 1642, Hexid A4, Coolflow IGE, NALCO®CCL105; SMC recommends Bypass Piping Set HRS-BP001 for Models HRS-012, HRS018

Cooling Capacity: 018 [Cooling Capacity: 1700/1900 W (50/60 Hz)], Pipe Thread: Rc, Option: V (Stainless Steel Panel Specification)

Cooling Capacity: 018 [Cooling Capacity: 1700/1900 W (50/60 Hz)], Pipe Thread: Rc, Option: T (High-pressure Pump Mounted)

A large digital display provides a clear view of the current and set values. 

Cooling Capacity: 018 [Cooling Capacity: 1700/1900 W (50/60 Hz)], Pipe Thread: Rc, Option: Stainless Steel Panel Specification

Cooling Capacity: 018 (Cooling Capacity: 1700/1900W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: Rc

Cooling Capacity: 018 (Cooling Capacity: 1700/1900W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set)

Cooling Capacity: 018 (Cooling Capacity: 1700/1900W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: F (G w/PT-G Conversion Fitting Set)

Cooling Capacity: 018 (Cooling Capacity: 1700/1900W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set)