filter to be done easily and without tools.Compact type thermal-chiller , Single phase, 100/115VAC, Cooling method: air-cooled or water-cooled , Self diagnosis and check display for easy maintenance , Functions: timer operation, low tank level detecting, power failure auto-restart, anti-freezing, PC BOARD / HRS012-A-10, OTHERS, HRS THERMO-CHILLERS, 21, HRS - NO SIZE RATING, .00000 lb
Please contact us for the latest version.sales@ocaire.com, PC BOARD / HRS012-W-10, OTHERS, HRS THERMO-CHILLERS, 21, HRS - NO SIZE RATING, .00000 lb
-AN-10, OTHERS, HRS THERMO-CHILLERS, 21, HRS - NO SIZE RATING, .00000 lb
OUT PIPE ASSY, HRS012~024-A-10/20, CHILLER, 729, 200 lb
~024-A/W-10/20, CHILLER, 729, 100 lb
Cooling Capacity: 012 (Cooling Capacity: 1100/1300W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set)
Type: -, Cooling Method: -, Cooling Capacity: 1,100/1,300 W (50/60 Hz), Piping thread type: NPT (PT-NPT conversion fitting set included), Optional specifications: None
to 24 VDC 10%, Ripple (P-P) 10% or less 15 mA or less 2% F.S.
10 10 5 4 3 4 5 3 4 5 3 2 2 2 1 1 1 1 5 10 20 10 5 1 20 30 10 5 1 20 30 Transfer speed (m/min) Transfer speed (m/min) Transfer speed (m/min) Lever-type weight of transferred object and transfer speed graphs (graphs (2) and (3)) show the values at room temperature (20 to 25C).
Switch bracket Auto switch b Switch holder d Auto switch mounting screw c Auto switch mounting band D-X Technical Data 375 CG3 Series Operating Range (mm) Auto switch model Bore size 20 25 32 40 50 63 80 100 D-M9(V) D-M9W(V) D-M9A(V) 4.5 5.0 4.5 5.5 5.0 5.5 D-A9 7 6 8 8 8 9 D-C7/C80 D-C73C/C80C D-B5/B64 D-B59W D-H7/H7W D-H7NF/H7BA 9 8 10 10 10 11 8 10 9 10 10 11 11 11 13 13 14 14 14
M10 x 1.25 M14 x 1.5 M16 x 1.5 12 M4 10 10 7 5.5 5.5 6.5 M4 set screw (1 pc.) 30 10 16 22 60 46 30 12 M4 10 10 7 5.5 5.5 6.5 36 12 16 30 80 56 40 12 M5 12 13 7 9 7 10 M5 set screw (1 pc.) 44 12 24 30 88 64 43 16 M5 12 13 9 9 10 10 Y-type double knuckle joint Bracket pin 20: Y-020B 25: Y-032B 32: Y-04D 40: Y-04B 2 x D drill through RR1 RR1 C1 Chamfer NDH10 NDH10 MM C E1 E1 C1 Chamfer NZ NZ
Zone 40 :/ 1 30 " /' i 20 ;/ Danger Zone 10 SOOO 1
DA N4odels wi function at 10%oitheir maximum rated enerS/ percyce.lilessthan 10%, a snia ler modelshoud bespecned. 2. Prov de a positile stop 3nm before end of stroke in tension and cgr.pression to prevent nternal bottoming. 3.
2 outputs SI unit only Note 10) r Rated Voltage Note 8) w Nominal Nozzle Size Unit selection function Note 9) NPN 1 output Digital pressure System Nominal size Voltage Symbol 00 07 10 12 15 Symbol 5 6 0 SI unit only Note 10) switch for vacuum 100 to 100 24 VDC Vacuum pump system Unit selection function Note 9) with energy saving PNP 1 output 12 VDC 0.7 function Note 11) SI unit only Note
._ I 10, 22o, 12, 24, 48' 24ov sodoHz DC -24,6,12, 48, 100, 1 10v Voltag6 allowance 15.' + 10% of rated voltage lrcUlailon-Class B or equivalent Power consumptim AC Inrush-5.6VA(soHz)' 5.0VA(6OHZ) Hotdino-3.4VA(5OHz), 2.3VA(6OHz) DC_ 1.8W/2W (With LED) Indicator light Surg voltage supp(Gsor circuil AC ZNR (Varistor) ,Neon lamp (LED 10OV or le6s) DCDiode.
DescriPti~del AW2001 AW3001 AW4001 Bracket B220 B320 B420 t .0MPa 1 10kgf/cm2) GC30-10 Gauge Symbol O.2M Pa 1 2.0kgflcm2) GC30-2 Accessory NOlen Float type N.O. AD43 AD44 auto drain N.C. AD53 AD54 Differential pressure type auto drain AD62 NOle 1 )Mln. operallng pressure N.O. 0.1 MPa{1.0kgficm2}, N.C. 0.15MPa(1.5kgficm2) .?
Cooling Capacity: 012 (Cooling Capacity: 1100/1300W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: Rc, Option: BJ (B + J)