Type: Thermo-Chiller, Cooling Method: Water Cooling, Cooling Capacity: 1,100/1,300 W (50/60 Hz), Piping thread type: Rc, Optional specifications: With earth leakage circuit breaker / Compatible with deionized water (pure water) piping / High pump head specification
Type: -, Cooling Method: -, Cooling Capacity: 1,100/1,300 W (50/60 Hz), Piping thread type: Rc, Optional specifications: Compatible with deionized water (pure water) piping
Type: -, Cooling Method: -, Cooling Capacity: 1,100/1,300 W (50/60 Hz), Piping thread type: Rc, Optional specifications: High pump head specification
Cooling Capacity: Cooling Capacity: 1100/1300W, 50/60 Hz, Cooling Method: Water-cooled Refrigeration, Thread: Rc, Option: M + T
filter to be done easily and without tools.Compact type thermal-chiller , Single phase, 100/115VAC, Cooling method: air-cooled or water-cooled , Self diagnosis and check display for easy maintenance , Functions: timer operation, low tank level detecting, power failure auto-restart, anti-freezing, L/SIDE PANEL (HRS012/018/024), OTHERS, HRS THERMO-CHILLERS, 21, HRS - NO SIZE RATING, .00000
with the grill of the front panel allowing mounting and removal of the HRS filter to be done easily and without tools.Compact type thermal-chiller , Single phase, 100/115VAC, Cooling method: air-cooled or water-cooled , Self diagnosis and check display for easy maintenance , Functions: timer operation, low tank level detecting, power failure auto-restart, anti-freezing, Support Bracket HRS012
filter to be done easily and without tools.Compact type thermal-chiller , Single phase, 100/115VAC, Cooling method: air-cooled or water-cooled , Self diagnosis and check display for easy maintenance , Functions: timer operation, low tank level detecting, power failure auto-restart, anti-freezing, PC BOARD / HRS012-A-10, OTHERS, HRS THERMO-CHILLERS, 21, HRS - NO SIZE RATING, .00000 lb
filter to be done easily and without tools.Compact type thermal-chiller , Single phase, 100/115VAC, Cooling method: air-cooled or water-cooled , Self diagnosis and check display for easy maintenance , Functions: timer operation, low tank level detecting, power failure auto-restart, anti-freezing, R/SIDE PANEL (HRS012/018/024), OTHERS, HRS THERMO-CHILLERS, 21, HRS - NO SIZE RATING, .00000
integrated with the grill of the front panel allowing mounting and removal of the HRS filter to be done easily and without tools.Compact type thermal-chiller , Single phase, 100/115VAC, Cooling method: air-cooled or water-cooled , Self diagnosis and check display for easy maintenance , Functions: timer operation, low tank level detecting, power failure auto-restart, anti-freezing, BASE FOR HRS012
of the front panel allowing mounting and removal of the HRS filter to be done easily and without tools.Compact type thermal-chiller , Single phase, 100/115VAC, Cooling method: air-cooled or water-cooled , Self diagnosis and check display for easy maintenance , Functions: timer operation, low tank level detecting, power failure auto-restart, anti-freezing, Electric Conductiviy Sensor - HRS012
For the HRS012/018/024/030 option “T” (high-pressure pump) and the HRS050/060, after 8000 hours, alarm code “AL28” (pump maintenance) will be activated.
We recommend that you check for leaks and replace the mechanical seal at this time. Consider requesting maintenance from a maintenance company. We can recommend service providers if needed.
For the HRS012 to 060 and the HRSE series, alarm code “AL29” (fan motor maintenance) will be activated every 20,000 hours of operation (Note 1). Consider requesting maintenance from a maintenance company. We can recommend service providers if needed.
This is an accessory for the HRS012 to 060.
If it is lost or damaged, it can be ordered as an individual part.
The default setting for alarm code “AL09” is continued operation for the HRS012 to 060.
COM. 21 22 19 20 19 20 19 20 17 18 17 18 17 18 15 16 15 16 15 16 COM. COM. 13 14 13 14 13 14 11 12 11 12 11 12 9 10 9 10 9 10 9 10 7 8 7 8 7 8 7 8 5 6 5 6 5 6 5 6 3 4 3 4 3 4 3 4 1 2 1 2 1 2 1 2 COM. COM. (P: 26 pins) (PG: 20 pins) (PH: 10 pins) (J,G: 20 pins PC wiring) Mixed wiring of single and double wiring can be specified on the manifold specification.
VA or less 10 W or less 20 VA or less 10 W or less 20 VA or less 10 W or less 20 VA or less 10 W or less Power consumption Between case and AC line: 1500 VAC for 1 min.
*Trunnion mounting threads in flats NA are not available for 80, 100 bores Bore (mm) P WA WB WH W 20 M5x0.8 14 14 23 30 25 M5x0.8 14 14 25 30 D I M E N S I O N S A I R C U S H I O N T Y P E CDG1BA 32 18 14 13 28.5 25 40 18 15 14 33 20 50 14 16 15 40.5 20 63 14 16 15 47.5 20 80 38 22 22 60.5 20 100 12 22 22 71 20 Effective thread length Bore (mm) Stroke range (mm) A B C D E GB I J K KA MM
14 81 365 72 281 40 1/2 56.5 15 25 80 226 100 25 36 0 25 0~0.084 D I M E N S I O N S T R U N N I O N T Y P E CLAT WITH ROD BOOT Stroke Range Bore Effective Length A B BN BP BQ C D E F GA GB GC GD GL GR J K LZ MM MM W/O Boot W/Boot Size Of Thread X1US ~500 20~500 30 60 96 1/4 1/4 44 16 32 10 85 15 26 54 10 10 M8x1.25 6 71 M14x1.5 40 27 7/16-20 ~600 20~600 35 70 108 1/4 1/4 52 20 40 10 95 17
(Pad diameter: 20 mm or less only) ZP T 10 F N B5 A8 With adapter From p. 62 p. 119 From p. 127 ZP T 10 F N J 10 B5 A10 With buffer From p. 65 p. 120 From p. 129 q w e r t y u Ball joint type w Pad diameter t Buffer stroke q Vacuum inlet direction T Vertical R Lateral (With One-touch fitting) 10 10 13 13 16 16 20 20 25 25 32 32 40 40 50 50 Stroke [mm] Pad diameter [mm] 10 to 16 20 to 50 10
CDRB2 20 W B 180 S R73 L With auto switch Size: 20, 30, 40 Fittings are sold separately.