Cooling Capacity: Cooling Capacity: 1100/1300W, 50/60 Hz, Cooling Method: Water-cooled Refrigeration, Thread: Rc, Option: B + M + T
Cooling Capacity: Cooling Capacity: 1100/1300W, 50/60 Hz, Cooling Method: Water-cooled Refrigeration, Thread: Rc, Option: High-pressure Pump
Cooling Capacity: Cooling Capacity: 1100/1300W, 50/60 Hz, Cooling Method: Water-cooled Refrigeration, Thread: Rc, Option: Earth Leakage Breaker
filter to be done easily and without tools.Compact type thermal-chiller , Single phase, 100/115VAC, Cooling method: air-cooled or water-cooled , Self diagnosis and check display for easy maintenance , Functions: timer operation, low tank level detecting, power failure auto-restart, anti-freezing, LEFT SIDE PANEL (HRS012-AN-20), OTHERS, HRS THERMO-CHILLERS, 21, HRS - NO SIZE RATING,
filter to be done easily and without tools.Compact type thermal-chiller , Single phase, 100/115VAC, Cooling method: air-cooled or water-cooled , Self diagnosis and check display for easy maintenance , Functions: timer operation, low tank level detecting, power failure auto-restart, anti-freezing, L/SIDE PANEL (HRS012/018/024), OTHERS, HRS THERMO-CHILLERS, 21, HRS - NO SIZE RATING, .00000
filter to be done easily and without tools.Compact type thermal-chiller , Single phase, 100/115VAC, Cooling method: air-cooled or water-cooled , Self diagnosis and check display for easy maintenance , Functions: timer operation, low tank level detecting, power failure auto-restart, anti-freezing, PC BOARD / HRS012-A-20, OTHERS, HRS THERMO-CHILLERS, 21, HRS - NO SIZE RATING, .00000 lb
with the grill of the front panel allowing mounting and removal of the HRS filter to be done easily and without tools.Compact type thermal-chiller , Single phase, 100/115VAC, Cooling method: air-cooled or water-cooled , Self diagnosis and check display for easy maintenance , Functions: timer operation, low tank level detecting, power failure auto-restart, anti-freezing, Support Bracket HRS012
filter to be done easily and without tools.Compact type thermal-chiller , Single phase, 100/115VAC, Cooling method: air-cooled or water-cooled , Self diagnosis and check display for easy maintenance , Functions: timer operation, low tank level detecting, power failure auto-restart, anti-freezing, BYPASS KIT - HRS012-A-20-X047, OTHERS, HRS THERMO-CHILLERS, 27, HRS NO SIZE EUROPEAN
integrated with the grill of the front panel allowing mounting and removal of the HRS filter to be done easily and without tools.Compact type thermal-chiller , Single phase, 100/115VAC, Cooling method: air-cooled or water-cooled , Self diagnosis and check display for easy maintenance , Functions: timer operation, low tank level detecting, power failure auto-restart, anti-freezing, BYPASS TO HRS012
Please contact us for the latest version.sales@ocaire.com, MAIN PC BOARD / HRS012-A-20-MT, OTHERS, HRS THERMO-CHILLERS, 21, HRS - NO SIZE RATING, .00000 lb
with the grill of the front panel allowing mounting and removal of the HRS filter to be done easily and without tools.Compact type thermal-chiller , Single phase, 100/115VAC, Cooling method: air-cooled or water-cooled , Self diagnosis and check display for easy maintenance , Functions: timer operation, low tank level detecting, power failure auto-restart, anti-freezing, RIGHT SIDE PANEL HRS012
filter to be done easily and without tools.Compact type thermal-chiller , Single phase, 100/115VAC, Cooling method: air-cooled or water-cooled , Self diagnosis and check display for easy maintenance , Functions: timer operation, low tank level detecting, power failure auto-restart, anti-freezing, R/SIDE PANEL (HRS012/018/024), OTHERS, HRS THERMO-CHILLERS, 21, HRS - NO SIZE RATING, .00000
filter to be done easily and without tools.Compact type thermal-chiller , Single phase, 100/115VAC, Cooling method: air-cooled or water-cooled , Self diagnosis and check display for easy maintenance , Functions: timer operation, low tank level detecting, power failure auto-restart, anti-freezing, UPPER PANEL (HRS012-AN-20), OTHERS, HRS THERMO-CHILLERS, 21, HRS - NO SIZE RATING, .00000
OUTLET PIPE ASSY, HRS012~024-A-20, CHILLER, 729, 250 lb
of the front panel allowing mounting and removal of the HRS filter to be done easily and without tools.Compact type thermal-chiller , Single phase, 100/115VAC, Cooling method: air-cooled or water-cooled , Self diagnosis and check display for easy maintenance , Functions: timer operation, low tank level detecting, power failure auto-restart, anti-freezing, Electric Conductiviy Sensor - HRS012
For the HRS012/018/024/030 option “T” (high-pressure pump) and the HRS050/060, after 8000 hours, alarm code “AL28” (pump maintenance) will be activated.
We recommend that you check for leaks and replace the mechanical seal at this time. Consider requesting maintenance from a maintenance company. We can recommend service providers if needed.
For the HRS012 to 060 and the HRSE series, alarm code “AL29” (fan motor maintenance) will be activated every 20,000 hours of operation (Note 1). Consider requesting maintenance from a maintenance company. We can recommend service providers if needed.
This is an accessory for the HRS012 to 060.
If it is lost or damaged, it can be ordered as an individual part.
The default setting for alarm code “AL09” is continued operation for the HRS012 to 060.
Cooling Capacity: 012 (Cooling Capacity: 1100/1300W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: Rc, Option: M [Applicable to DI Water (Deionized Water) Piping]