--20, HRS024--20 . 9-11 9.6 Pump capacity . 9-12 9.6.1 HRS012--10-(BJM), HRS018--10-(BJM) . 9-12 9.6.2 HRS012--20-(BGJM), HRS018--20-(BGJM), HRS024--20-(BGJM) . 9-12 9.6.3 HRS012--10-T, HRS018--10-T, HRS012--10-MT, HRS018--10-MT . 9-13 9.6.4 HRS012--20-T, HRS018--20-T, HRS024--20-T . 9-13 9.6.5 HRS012--20-MT, HRS018--20-MT, HRS024--20-MT . 9-14 9.7 Required facility water flow (for water-cooled
Bore size Stroke adjustment range A B MH MT MA MI MM MK ML G L 12 to 25 MM MI 12 16 20 25 25 (15) 57.7 (64.9) 25.2 (32.4) 3.5 29 M4 x 0.7 5.5 14 5 20 8 5 to 30 28 (20) 26 (36) 58.5 (68.5) 3.5 29 M5 x 0.8 5.5 14 5 20 10 G 36 (25) 26 (38) M6 x 1 67.5 (79.5) 4.5 37 7 20 8 24 12 5 to 50 MK MT ML L MA 40 (30) 29 (39) M6 x 1 71 (81) 5 37 7 20 8 24 12 5 to 50 30.5 (40.5) 78.5 (88.5) Stroke 32 38
Cooling Capacity: 018 [1600/1800 W (50/60 Hz)], Cooling Method: A (Air-cooled), Pipe Thread: N [NPT (with Rc-NPT Conversion Fitting Set], Option 1: T (High-pressure Pump Mounted)
Cooling Capacity: 018 [1600/1800 W (50/60 Hz)], Cooling Method: A (Air-cooled), Pipe Thread: N [NPT (with Rc-NPT Conversion Fitting Set], Option 1: None
Cooling Capacity: 018 [1600/1800 W (50/60 Hz)], Cooling Method: A (Air-cooled), Pipe Thread: N [NPT (with Rc-NPT Conversion Fitting Set], Option 1: DM (w/Electric Conductivity Control Function, Applicable to DI Water Piping)
Cooling Capacity: 018 [1600/1800 W (50/60 Hz)], Cooling Method: A (Air-cooled), Pipe Thread: N [NPT (with Rc-NPT Conversion Fitting Set], Option 1: MT (M + T)
Cooling Capacity: 018 [1600/1800 W (50/60 Hz)], Cooling Method: A (Air-cooled), Pipe Thread: N [NPT (with Rc-NPT Conversion Fitting Set], Option 1: DMT (DM + T)
Cooling Capacity: 018 [1600/1800 W (50/60 Hz)], Cooling Method: A (Air-cooled), Pipe Thread: N [NPT (with Rc-NPT Conversion Fitting Set], Option 1: DM (w/Electric Conductivity Control Function, Applicable to DI Water Piping), Option 2: Y (w/Feet, w/o Rack Mounting Brackets)
Cooling Capacity: 018 [1600/1800 W (50/60 Hz)], Cooling Method: A (Air-cooled), Pipe Thread: N [NPT (with Rc-NPT Conversion Fitting Set], Option 1: T (High-pressure Pump Mounted), Option 2: Z1 (No Flow Sensor or Retaining Clip)
Cooling Capacity: 018 [1600/1800 W (50/60 Hz)], Cooling Method: A (Air-cooled), Pipe Thread: N [NPT (with Rc-NPT Conversion Fitting Set], Option 1: M (Applicabe to DI Water Piping)
Cooling Capacity: 018 [1600/1800 W (50/60 Hz)], Cooling Method: Air-cooled, Pipe Thread: N [NPT (with Rc-NPT Conversion Fitting Set], Option 1: High-pressure Pump Mounted, Option 2: -
Cooling Capacity: 018 [1600/1800 W (50/60 Hz)], Cooling Method: Air-cooled, Pipe Thread: N [NPT (with Rc-NPT Conversion Fitting Set], Option 1: None, Option 2: -
Cooling Capacity: 018 [1600/1800 W (50/60 Hz)], Cooling Method: Air-cooled, Pipe Thread: N [NPT (with Rc-NPT Conversion Fitting Set], Option 1: w/Electric Conductivity Control Function, Applicable to DI Water Piping, Option 2: -
Cooling Capacity: 018 [1600/1800 W (50/60 Hz)], Cooling Method: Air-cooled, Pipe Thread: N [NPT (with Rc-NPT Conversion Fitting Set], Option 1: M + T, Option 2: -
Cooling Capacity: 018 [1600/1800 W (50/60 Hz)], Cooling Method: Air-cooled, Pipe Thread: N [NPT (with Rc-NPT Conversion Fitting Set], Option 1: DM + T, Option 2: -
Cooling Capacity: 018 [1600/1800 W (50/60 Hz)], Cooling Method: Air-cooled, Pipe Thread: N [NPT (with Rc-NPT Conversion Fitting Set], Option 1: w/Electric Conductivity Control Function, Applicable to DI Water Piping, Option 2: w/Feet, w/o Rack Mounting Brackets
Cooling Capacity: 018 [1600/1800 W (50/60 Hz)], Cooling Method: Air-cooled, Pipe Thread: N [NPT (with Rc-NPT Conversion Fitting Set], Option 1: High-pressure Pump Mounted, Option 2: No Flow Sensor or Retaining Clip
Cooling Capacity: -, Cooling Method: -, Pipe Thread: -, Option 1: -, Option 2: -
Cooling Capacity: 018 [1600/1800 W (50/60 Hz)], Cooling Method: Air-cooled, Pipe Thread: N [NPT (with Rc-NPT Conversion Fitting Set], Option 1: Applicabe to DI Water Piping, Option 2: -
For HRR050-AF-20/40G thread adapter set 1 set For HRR050-AN-20/40NPT thread adapter set 1 set 1 In the case of option Z, not included.