SMC Corporation of America
Elite Part Number Search
Search Results "GZ46-K1K-01"

Atmospheric pressure Vacuum pressure switch set value Vacuum pressure at operation Vacuum pressure switch ZSE10, ZSE30A Flow sensor PFMV Vacuum pressure gauge GZ46 Vacuum pressure switch Refer to the Best Pneumatics No. 8 for details.

Atmospheric pressure Vacuum pressure switch set value Vacuum pressure at operation Suction verification switch ZSP1 Flow sensor PFMV Vacuum pressure gauge GZ46 Vacuum pressure switch Refer to the Best Pneumatics No. 6 for details.

The G46, G46E, G46-L, G46-SRA/B, GZ46, GZ46E, and GP46 can be panel mounted. Dedicated attachments (cover ring assemblies) are required.
When ordering a pressure gauge with an attachment, indicate “-C” (irremovable clear cover with no protrusion) or “-C2” (removable clear cover with protrusion/with protruding wrench flats) in the part number.

Specifications: E (Oil-free, External parts copper-free), Display Pressure: K1 (-100 to 100 kPa), Connection Thread: 01 (R 1/8)

Type: Pressure Monitor, Sensor, Monitor Structure: Integrated, Output Method: Analog, Pipe Port Type: [Threads] Male thread, Plumbing Thread Type: [Rc (R)] R, Pressure Resistant(kPa): 100, Operating Temperature Range(°C): 18~28, Response Differential(kPa): ±3, Pipe Connection Direction: Back, Plumbing Thread Nominal: [1/8] 1/8, Rated Pressure Range(kPa): -100 to 100, Compatible Fluid: Air

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, GAUGE, VACUUM SERIES, GZ VACUUM GAUGE, JD, GZ 1/8 PORTED, 0.36863 lb

Part Number Description: GAUGE   Product Line: Z   Product Line Description: VACUUM SERIES   Family Code: 625   Family Description: GZ VACUUM GAUGE   Class Code: JC   Part Code: 2   Reference Code:  K   PDF Documentation:  Datasheet   Click here to report information errorImage shown may not match exact part number

Type: Pressure Monitor, Sensor, Monitor Structure: Integrated, Output Method: Analog, Pipe Port Type: [Threads] Male thread, Plumbing Thread Type: [Rc (R)] R, Pressure Resistant(kPa): 200, Operating Temperature Range(°C): 18~28, Response Differential(kPa): ±3, Pipe Connection Direction: Back, Plumbing Thread Nominal: [1/8] 1/8, Rated Pressure Range(kPa): -100 to 200, Compatible Fluid: Air

Type: Pressure Monitor, Sensor, Monitor Structure: Integrated, Output Method: Analog, Pipe Port Type: [Threads] Male thread, Plumbing Thread Type: [Rc (R)] R, Pressure Resistant(kPa): 100, Operating Temperature Range(°C): 18~28, Response Differential(kPa): ±3, Pipe Connection Direction: Back, Plumbing Thread Nominal: [1/8] 1/8, Rated Pressure Range(kPa): -100 to 0, Compatible Fluid: Air,

Specifications: E (Oil-free, External parts copper-free), Display Pressure: K1 (-100 to 100 kPa), Connection Thread: 01 (R 1/8), Option: None, Attachment: C (Clear Cover w/o Protrusion, is not Removable)

Type: Pressure Monitor, Sensor, Monitor Structure: Integrated, Output Method: Analog, Pipe Port Type: [Threads] Male thread, Plumbing Thread Type: [Rc (R)] R, Pressure Resistant(kPa): 100, Operating Temperature Range(°C): 18~28, Response Differential(kPa): ±3, Pipe Connection Direction: Back, Plumbing Thread Nominal: [1/8] 1/8, Rated Pressure Range(kPa): -100 to 100, Compatible Fluid: Air

Specifications: None, Display Pressure: -100 to 0 kPa, Connection Thread: 01 (R 1/8), Option: None, Attachment: C (Clear Cover w/o Protrusion, is not Removable)

Specifications: None, Display Pressure: -100 to 0 kPa, Connection Thread: 01 (R 1/8), Option: None, Attachment: C2 (Clear Cover w/Protrusion, is Removable, Wrench Flats Protrude)

Specifications: None, Display Pressure: K2 (-100 to 200 kPa), Connection Thread: 01 (R 1/8), Option: None, Attachment: C2 (Clear Cover w/Protrusion, is Removable, Wrench Flats Protrude)

Specifications: None, Display Pressure: -100 to 200 kPa, Connection Thread: R 1/8, Option: None, Attachment: Clear Cover w/Protrusion, is Removable, Wrench Flats Protrude

Type: Pressure Monitor, Sensor, Monitor Structure: Integrated, Output Method: Analog, Pipe Port Type: [Threads] Male thread, Plumbing Thread Type: [Rc (R)] R, Pressure Resistant(kPa): 100, Operating Temperature Range(°C): 18~28, Response Differential(kPa): ±3, Pipe Connection Direction: Back, Plumbing Thread Nominal: [1/8] 1/8, Rated Pressure Range(kPa): -100 to 0, Compatible Fluid: Air,

Type: Pressure Monitor, Sensor, Monitor Structure: Integrated, Output Method: Analog, Pipe Port Type: [Threads] Male thread, Plumbing Thread Type: [Rc (R)] R, Pressure Resistant(kPa): 100, Operating Temperature Range(°C): 18~28, Response Differential(kPa): ±3, Pipe Connection Direction: Back, Plumbing Thread Nominal: [1/8] 1/8, Rated Pressure Range(kPa): -100 to 0, Compatible Fluid: Air,