SS5V2-10 SS5V3-10 SS5V4-10 Note) The value is for manifold base with 5 stations and individually operated 2 position type.
L1 (3 x P) Q1 = M C2 = C Y = C1 = C C2 Y = L2 = L2 (3 x P) C2 = C L2 = Q2 = M L1 = X = DD2 = (mm) (mm) (mm) Y 1 to 9 1 to 10 D2 Q1 M3, M4 M3, M4, M5 Q2 M3, M4 M3, M4, M5 L2 max Y Y Y 6 to 9 7.5 to 10 X 8 to 18 9.5 to 20 L1 max X 2 X 2 L2 max Y Y Size 10 15 Size 10 15 Size 10 15 3.5 to 4.9 3.5 to 5.9 257 Series CRQ2 (Size: 10, 15, 20, 30, 40) Simple Specials: -XA1 to -XA24: Shaft Pattern
Applicable shaft type: W L1 (3 x P) Q1 = M C2 = C Y = DC1 = C C2 Y = L2 = L2 (3 x P) C2 = C L2 = Q2 = M L1 = X = D2 = (mm) (mm) (mm) Y 1 to 9 1 to 10 L2 max Y Y D2 L1 max X 2 X 2 L2 max Y Y Q1 M3, M4 M3, M4, M5 Q2 M3, M4 M3, M4, M5 Y 6 to 9 7.5 to 10 X 8 to 18 9.5 to 20 Size 10 15 Size 10 15 Size 10 15 3.5 to 4.9 3.5 to 5.9 319 CRQ2X Series (Size: 10, 15, 20, 30, 40) Simple Specials: -
Q1= M L1 (3 x P) C1 = C C2 = C Y = C2 Y = L2 = C2 = C L2 = L2 (3 x P) L1 = X = Q2 = M D2 = (mm) (mm) (mm) Y 1 to 9 1 to 10 D2 Q1 M3, M4 M3, M4, M5 Q2 M3, M4 M3, M4, M5 L2 max Y Y Y 6 to 9 7.5 to 10 Size 10 15 Size 10 15 Size 10 15 L1 max X 2 X 2 X 8 to 18 9.5 to 20 L2 max Y Y 3.5 to 4.9 3.5 to 5.9 11-8-13 14 Series CRQ2 (Size: 10, 15, 20, 30, 40) Simple Specials: -XA1 to -XA24: Shaft Pattern
Form w 1 Material e Buffer spec. r Buffer stroke t Vacuum inlet Flat Type with Groove A 3 30.5 11 1.2 11 04 6 37 14 14.5 10 47 18 20.5 J K Width across flats E 3 30.5 11 1.8 11 6 37 14 14.5 10 47 18 20.5 06 08 N S U F GN GS HS 7 15 55 36.5 1.2 10 20 62.5 44 06 08 15 55 36.5 1.8 20 62.5 44 04 JB K ZP3 T UM B5 C2 3 31.5 12 11 J K 10 6 38 15 14.5 10 48 19 20.5 JB K 15 56 37.5 10 20 63.5 45 10
Supply from one side 8 10 10 M5 x 0.8 Supply from both sides 10 12 12 Note) These values are obtained under the standard supply pressure.
End Plate EX600-ED2-l EX600-ED3-l Power connector Model specification M12 (5-pin) plug 7/8 inch (5-pin) plug 24 VDC 10%, Class 2, 2 A 24 VDC 10%, 8 A Power supply (for Control/Input) Power supply (for Output) 24 VDC +10/5%, Class 2, 2 A 24 VDC +10/5%, 8 A Enclosure IP67 (Manifold assembly) Standards CE marking, UL (CSA), RoHS recognition Weight 0.4 lbs (170 g) 0.4 lbs (175 g) EX600-ED3-l
D-M9A D-M9V Qty. of auto switches mounted D-A9 D-M9 D-P3DW Note 1) 5 10(5) 15 (10) 15 (5) 1 pc. 10 15 5 10 10 15 (10) 15 (5) 2 pcs. 10 15 5 Note 1) 25 is only applicable for D-P3DW.
Weight [g] JXC-C2-1 160 JXC-C2-3 300 JXC-C2-5 480 DIN rail L For 3 Axes For 4 Axes 5.25 12.5 (Pitch) JXC92 JXC73/83/93 7.5 AXT100 DR * For , enter a number from the No. line in the table below.
/Side ported Type 11/Bottom ported Symbol A, B port Type 10/Side ported Type 11/Bottom ported SY3000 SY5000 SY7000 SY5000 SY7000 N1 SY3000 SY5000 SY7000 SY5000 SY7000 C2 1/8" V N3 5/32" V V V N7 1/4" V V V V V N9 5/16" V V V V N11 3/8" V V 2 V C3 3.2 V C4 4 V V V C6 6 V V V V V C8 8 V V V V C10 10 V V C12 12 V V Straight Straight CM* Straight port, mixed sizes V V V V V LN3
ZS-10-5A-50 . 1 pc.
Single Piston Actuator size Recommended model Piping condition Bore size (mm) Stroke (mm) Tube O.D. 2 mm IDK02-100 IDK02-200 Tube O.D. 4 mm IDK04-100 IDK04-200 Tube O.D. 6 mm IDK06-100 IDK06-200 Tube length (m) 5 10 5 10 5 10 5 10 5 10 5 10 5 10 5 10 5 10 5 10 5 10 5 10 2.5 All strokes 4 All strokes Less than 10 6 10 or more Less than 10 8 10 or more Less than 10 10 10 or more Less than 10
Power supply for solenoid valves: 24 VDC +10%/-5% 68 No.EX-OMS0014-A Fault No. 10 Fault Possible cause Investigation method Countermeasures Tighten the branch cable connection. (if there is a broken wire, replace the cable) Power supply for input and control: 24 VDC 10% SI unit PWR LED is OFF. Check the branch cable connections and check for broken wires.
-SS5V1-10 10-SS5V2-10 10-SS5V3-10 10-SS5V4-10 Note) The values are for individually operated 2 position type manifold bases with 5 stations.
-06-06-08 ZH13DS-08-10-10 ZH13DL-08-10-10 ZH15DS-10-12-12 ZH15DL-10-12-12 12.8 6 24 21 7.8 6 17 24 12.8 6 24 21 6 17 24 12.8 6 24 22 6 17 24 12.8 6 24 22 6 17 24 13.7 6 26 24.5 8 20 28 13.7 6 26 24.5 8 20 28 15.3 10 28 27 10 22 30 15.3 10 28 27 10 22 30 Applicable tubing diameter J 7.8 7.8 7.8 9.6 9.6 10.7 10.7 ZH ZU Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco,
, 13, 15 For nozzle size 18, 20 For nozzle size 10, 13, 15 For nozzle size 18, 20 e r t For nozzle size 10, 13, 15 [For ZSE4 spec.]
Z type 24 VDC: 7% to +10% 12 VDC: 4% to +10% T type 24 VDC: 5% to +10% 12 VDC: 6% to +10% Response Time Response time ms (at 0.5 MPa) 7 or less Mass Valve model Number of solenoids 1 pc. (Single) 2 pcs.
Solenoid valve No. 3 4 3 2 1 15 (For C2: 16) 2 No. 4 No. 3 No. 2 No. 1 21.6 4 3 (2) 26 6 2 1 1 No.1 Groove side Barb fitting [1(P), 2(A), 3(R) port] Applicable tubing O.D. 4, I.D. 2.5, Polyurethane tubing (made by SMC) Soft nylon tubing (made by SMC) Connector (For C2) (33.3) (L = 300 to 1000) Lead wire length Cut dimension for panel mount (mounting surface) 32.6 31 25 20 (10) (10) 6 (15)
Applicable bore size A1 L L1 MM Y-J010C 10 8 15.2 21 M4 x 0.7 Part no. Applicable bore size B1 C1 d H1 Part no. Applicable bore size B2 C2 d H2 SNJ-010C 10 11 12.7 M8 x 1.0 4 NTJ-010C 10 7 8.1 M4 x 0.7 3.2 Y-J016C 16 11 16.6 21 M5 x 0.8 SNJ-016C 16 14 16.2 M10 x 1.0 4 Part no.