Model Pressure range *1 Indication unit Connection thread Note MPa Port size 01 Rc1/8 02 Rc1/4 R1/8 R1/4 G46-7-02-SRB 0 to 0.7 R1/4 G46-10-02-SRB 0 to 1.0 G46-4-01 to 02-SRB 0 to 0.4 MPa Set pressure range: 0.05 to 0.69 MPa 02 WR110 X215 *1: Do not apply more pressure than the max. pressure displayed. It may cause a malfunction.

Model Pressure range *1 Indication unit Connection thread Note MPa Port size 01 Rc1/8 02 Rc1/4 R1/8 R1/4 G46-7-02-SRB 0 to 0.7 R1/4 G46-10-02-SRB 0 to 1.0 G46-4-01 to 02-SRB 0 to 0.4 MPa Set pressure range: 0.05 to 0.69 MPa 02 WR110 X215 *1: Do not apply more pressure than the max. pressure displayed. It may cause a malfunction.

G46-10-01 2 pcs. G27-10-R1-X209 2 pcs. G27-10-R1-X209 2 pcs. G46-10-01 2 pcs.

Filter plate 2 Series FN1 Flow Characteristics (Initial Value) Test fluid: Potable water Liquid temperature: 17 to 20C (room temperature) Test method: Per P/A test method (sanitary test stand) Element length 250mm: FN111-10-S Element length 500mm: FN112-10-S .1 .1 .05 .05 FN111-10-S005 (5m) Pressure loss (MPa) Pressure loss (MPa) FN112-10-S005 (5m) FN111-10-S020 (20m) .01 .01 FN112-10-S020

G46-10-01) indicates the type of threads used for connection. For Rc, leave the symbol blank, and for NPT, enter N. Please contact SMC concerning the supply of NPT pressure gauges. Relieving type is provided as standard for AU100.

G46-10-01) indicates the type of threads used for connection. For Rc, leave the symbol blank, and for NPT, enter N. Please contact SMC concerning the supply of NPT pressure gauges. Relieving type is provided as standard for AU100.

G46-10-01 1 Pressure gauge 11 G46-4-01-L 1 Pilot valve 12 81022P 1 O-ring 13 NBR KA00078 1 O-ring 14 FKM KA00099 2 Regulator 15 INA-13-717 1 VO307KG1-X328 1 2 5 1 2 5 VO315-00 G Solenoid valve 16 1 Solenoid valve 17 1 O-ring 18 NBR 4 KA00087 1065 A LMU100/200 Series Related Products Mixing Valve: LMV Series Specifications Inlet air pressure Ambient and fluid temperature 0.3 MPa Max. 5

, IDF6E-10 IDF8E-10, IDF11E-10 Type 100 V 10 A IDU3E-10, IDU4E-10 IDU6E-10 30 mA IDF4E-20, IDF6E-20 IDF8E-20, IDF11E-20 Type 200 V 5 A IDU3E-20, IDU4E-20 IDU6E-20 S Option symbol IDF1E-10 to 11E-10, IDU3E-10 to IDU6E-10 With power cord connection The option allows the connection of a power cord to a terminal block.

32A VEX9-32A VEX1-18-2A VEX1-18-2A F Foot (With bolt and washer) G27-10-R1-X207 G27-10-01 G36-10-01 G46-10-01 G Pressure gauge AN120-M5 N Silencer for breed port (PE) The optional parts are shipped in the same package.

Model Model name IC AMR3000 AMR4000 AMR5000 AMR6000 Bracket 13576 13556 13587 13568 VBA G36-10-01 G46-10-02 Pressure gauge 1.0 MPa (5)(6) Accessory (Option)/Part No.

G36-10-01) indicates thread. Specify no symbol for Rc, and N for NPT. Please consult with SMC if NPT gauge is required. Note 6) Use caution not to tighten excessively when mounting a pressure gauge, otherwise it may result in a breakdown. Use a sealant tape for sealing. Note 7) Piping adapter, O-ring, Hexagon socket bolt, Hexagon socket bolt assembly.

Model Description AMR3000 AMR4000 AMR5000 AMR6000 Bracket 13576 13556 13587 13568 G36-10-l01 G46-10-l02 Gauge (5) 1.0MPa Accessories (Options)/Part No.


The part number of the standard AR20 to AR60 round type pressure gauge is “G36-10-01,” or “G46-10-01”(for the R thread type).
For example, the part number of the AR30-03BG-A pressure gauge is “G36-10-01.” Details on the round type pressure gauge (with color zones) can be found https://www.smcpneumatics.com/Part-Builder-Links_ep_2458-1.html?https://smccatalog.partbuilder.smcpneumatics.com/support/faq/en-jp/?ca_id=vacuum-regulators&fa_id=10961


The part numbers of standard AR20 to AR60 round type pressure gauges are “G36-10-01” and “G46-10-01”(for the R thread type).
For example, the part number of the AR30-03BG-A pressure gauge is “G36-10-01.”
Details on the round type pressure gauge (with color zones) can be found https://www.smcpneumatics.com/Part-Builder-Links_ep_2458-1.html?https://smccatalog.partbuilder.smcpneumatics.com/support/faq/en-jp/?ca_id=combination-units&fa_id=10974

Basic type Select type Model VEX5504 06 10 VEX57-10 12 VEX59-14 20 P1 P1 VEX VEX Description Bracket (With bolt and washer) G46-10-01 VEX7-32A VEX5-32A VEX9-32A Air operated External pilot solenoid valve 3(R) 3(R) Pressure gauge 1(P) 3(R) 3(R) 1(P) P2 P2 P3 P1 P1 3(R) 3(R) 3(R) 3(R) 1(P) 1(P) P2 P2 Note) With this valve, the port 3(R) is a supply port and port 1(P) is an exhaust port. 2441

Option J: With drain guide Bracket (Option) 1/4B female thread T: With element service indicator Maintenance space HA Drain AT ID AMG AFF Element service indicator Dimensions with mounting bracket Model Port size (Nominal size B) A B C D E F G H 10 10 10 10 10 10 10 10 10 I 56 66 66 80 80 90 90 100 150 J 15 20 17 22 19 25 21 30 40 K 5 8 8 8 8 10 10 10 15 L 9 12 12 14 14 14 14 16 20 M 5.5

-4-01-SRB 2-color display digital pressure switch 10-ISE series 332 Applications Applications Air-blow HAA HAW AT IDF IDU IDF FS N2 blow to prevent lead frame oxidation, N2 blow to prevent detection camera blur Prevents traces of water droplets.

Pressure Gauge: G46 (ø42 Outside Diameter, Back Side Thread), Display Pressure: 10 (1.0MPa), Connection Thread: 01 (R 1/8), Attachment: None, Option: X2 (Nickel Plated)

Pressure Gauge: G46 (ø42 Outside Diameter, Back Side Thread), Display Pressure: 10 (1.0MPa), Connection Thread: 01 (R 1/8)

Pressure Gauge: G46 (ø42 Outside Diameter, Back Side Thread), Display Pressure: 10 (1.0MPa), Connection Thread: 01 (R 1/8), Attachment: C (Clear Cover Non Removable, Wrench Tighten)