output 2-byte output 2-byte output Wireless master module construction Input data: [Unit 1] Digital input unit (EX600-DXD): 2 bytes occupied Output data: [Unit 0] Digital output unit (EX600-DYB): 1 byte occupied [Unit 2] Wireless master unit (EX600-WEN#): 2 bytes occupied Unit 0 Unit 1 Unit 2 Unit 3 DYB AXA DXD EX600-WSV# Wireless slave unit setting parameter (Wireless channel 001) Valve
SI"PWR"LED 24 V10 1 POWER LED 2 ERROR LED EX600 LCD 3 LCD LCD Warning System access is not completed." 4 Ex600 SI"ST(M)"LED/ SI 5 " EX600 SI"ST(M)"LED/ 6 -50No.EX-OML0010CN-C 0 1 2 3 4 5 6 7 8 9 ON/OFF 1015 16 17 18 19 () 20 () 21 22 23 -51No.EX-OML0010CN-C SI EX600-DXB EX600-DXC EX600-DXC1 DX(8DI) DX EX600-DXD EX600-DXE EX600-DXF DX(16DI) DY(8DO) EX600-DYB DY(16DO) EX600
EX600-DM E EX600-DM F EX600-DY B EX600-DY E EX600-DY F EX600-DX B EX600-DX C EX600-DX D EX600-DX E EX600-DX F 1 1 2 1 1 Description Function 6 6 6 6 2 3 2 3 Displays the status of the unit. 2 2 5 5 5 5 3 3 4 4 1 1 2 1 1 6 6 6 6 2 3 2 3 2 3 5 5 5 5 3 4 4 Valve plate mounting groove 1 1 6 6 Valve plate (EX600-ZMV ) 1 5 2 2 3 5 5 3 Direct mounting (1)When joining six or more units, fix the middle
Refer to the catalog for SY series.) (1)When joining six or more units, fix the middle part of the complete EX600 unit with an intermediate reinforcing brace (EX600-ZMB2) before mounting, using 2-M4x6 screws. Tightening torque: 0.7 to 0.8 Nm. (2)Mount the end plate bracket (EX600-ZMA2) to the end plate at the opposite end to the valves, using 2-M4x14 screws.
(16 outputs) 0 1 Digital output unit EX600-DYF (16 outputs) 0 1 EX600-DME (8 inputs/8 outputs) 1 1 Digital I/O unit EX600-DMF (8 inputs/8 outputs) 1 1 Analog input Unit EX600-AXA 2 (1 word / 1 channel) 0 (2 channels) (2 channels) 0 2 Analog output Unit EX600-AYA (1 word / 1 channel) Analog I/O Unit EX600-AMB 2 2 (2/2 channels) (1 word / 1 channel) (1 word /1 channel) Note) 1 word is equivalent
PNP NPN PNP NPN EX600 D -9No.EX-OMN0037CN-A (1) 1.51.6 Nm (2) 1 10 SI (3)SI SI -10No.EX-OMN0037CN-A (4) (M3X8)(EX600-ZMV) 0.60.7 Nm SV 2 S0700 2 VQC10002 VQC20003 VQC40004 SY 2 (5)SI SI (M46) 0.70.8 Nm -11No.EX-OMN0037CN-A (1)6 2 (M45)(EX600-ZMB1) EX600 0.70.8 Nm (2)() (M4) 0.70.8 Nm n()10 -12No.EX-OMN0037CN-A DIN (SY SY ) (1)6 2 (M46)DIN (EX600-ZMB2) EX600 0.70.8
Screen for the EX600-SPN3/4 (1) (2) (4) (3) Fig. Screen for the EX600-SEN7/SEN8, and EX600-SEN3-X80 -21No.EX-OMY0032-B 8.5.2. Setting the IO-Link Module Parameters (Only possible when not connected to PLC) (for the EX600-SEN7/SEN8, and EX600-SEN3-X80 only) The following shows the procedure to set the parameters of the EX600-L#B1.
The cost effective and clean looking AC series allows you to pick a combination of modular style air preparation equipment that best suits your needs. The series, available in 8 size options to ensure optimum performance, offers energy savings, with higher flow rates. Simple assembly and maintenance reduces downtime. New Style piping adapter attachment , Easy maintenance , Detach equipment
-byte output 2-byte output 2-byte output Wireless master module construction Input data: [Unit 1] Digital input unit (EX600-DX#D): 2 bytes occupied Output data: [Unit 0] Digital output unit (EX600-DY#B): 1 byte occupied [Unit 2] Wireless master unit (EX600-WEN#): 2 bytes occupied Unit 0 Unit 1 Unit 2 Unit 3 DY#B AXA DX#D EX600-WSV# Wireless slave unit setting parameter (Wireless channel 001
-AXA EX600-ED2 EX600-ED3 EX126D-SMJ1 VVQC1000-74A-2 VVQC1000-P25-1 VVQC1000-F26-1 VVQC1000-T0-1 VVQC1000-80A-D VVQC1000-74A-1 VVQC1000-L25-0-1 VVQC1000-L25-1-1 VVQC1000-L25-2-1 VVQC1000-M26-1 No.
EX600-LAB1 EX600-LBB1 Common for IO-Link port No. 1, 2, 3 and 4 (C/Q: Pin No.4) of EX600-LAB1 and EX600-LBB1 The LED status varies depending on the setting of Pin No.4 (disabled, IO-Link communication, digital I/O) of ports No. 1 to 4.
Auto switch M12 M12 M12 M12 x 2 K #6 K #4 EX600-DX B, DX D M8 M8/M12 connector (Field-wireable/Pre-wired) EX600-DX C, DX C1 M12 M8 x 2 K #7 K #4 Only the M12 type connector is available for the 2-input type input block. Pre-wired type P Product Table Description Application No. SMC part no.
Installation Base 1 Direct mounting (1) When joining six or more units, fix the middle part of the complete EX600 unit with an intermediate reinforcing brace (EX600-ZMB1) before mounting using 2-M4 x 5 screws. Tightening torque: 0.7 to 0.8 Nm 2 4 5 10 Thank you for purchasing an SMC EX600-WEN#/EX600-WSV# SMC Wireless System.
Analog output unit EX600-AYA 1 4 6 5 DIN rail mounting groove 4 Analogl I/O unit EX600-AMB Valve plate mounting groove 1 Intermediate reinforcing brace (EX600-ZMB2) Intermediate reinforcing brace (EX600-ZMB1) 1 2 6 DIN rail 2 Valve plate (EX600-ZMV ) 1 End plate bracket (EX600-ZMA2) 5 2 5 3 3 4 Configuration Examples of wiring with input devices When using a sensor whose analog output signal
Fittings & Tubing Air Cylinders Rotary Actuators Example (10-SS5V1) 2-position single 10-SV1100-5FU 2-position double 10-SV1200-5FU Digital Output Unit EX600-DYPB Digital Input Unit EX600-DXPD SI Unit Note) Manifold Power supply with M12 connector EX600-SDN1A End plate Note) EX600-ED2 B A A B For the I/O Unit part number mounted, refer to the Best Pneumatics No. 1.
Installation Base 1 Direct mounting (1) When joining six or more units, fix the middle part of the complete EX600 unit with an intermediate reinforcing brace (EX600-ZMB1) before mounting using 2-M4 x 5 screws. Tightening torque: 0.7 to 0.8 Nm 2 4 5 10 Thank you for purchasing an SMC EX600-WPN# SMC Wireless System.
Connector 0 Connector 1 2 3 1 Direct mounting (1)When joining six or more units, fix the middle part of the complete EX600 unit with an intermediate reinforcing brace (EX600-ZMB1) before mounting using 2-M4x5 screws. Tightening torque: 0.7 to 0.8 Nm. Connector 3 EX600-LAB1/EX600-LBB1 Connector 2 Thank you for purchasing an SMC EX600 Series Fieldbus system.
Connector pin assignment 6 Specifications Configuration 9 10 7 Pin number Signal name PORT1 PORT2 8 TD+ 1 1 2 1 2 EX600-SPN3 Model EX600-SPN4 No. Description Function 2 RD+ To obtain more detailed information about operating this product, please refer to the SMC website (URL https://www.smcworld.com) or contact SMC directly.
Summary of Product parts LED Display 5 The status display LED displays the power supply and communication status. 1 2 1 3 End plate bracket (EX600-ZMA2) EX600-SEN7/EX600-SEN8 11 4 5 Wiring Thank you for purchasing an SMC EX600 Series Fieldbus system. Please read this manual carefully before operating the product and make sure you understand its capabilities and limitations.