SMC Corporation of America
Elite Part Number Search
Search Results "EQY25HA-50-B6"

JIS symbol Double acting Minimum Strokes for Auto Switch Mounting Stroke Long stroke (2) (mm) Max stroke (mm) Number of switches Bore size (mm) Standard stroke (1) (mm) Auto switch model 2 1 D-C7/C8 D-B5/B6 D-H7 D-G5/K5 25, 50, 75, 100, 125, 150, 200 201 to 350 20 15mm 10mm 301 to 400 25 301 to 450 32 25, 50, 75, 100, 125, 150, 200, 250, 300 20mm 15mm 1500 301 to 800 40 D-B59W 301 to 1200

Coil rated voltage VP7 1 2 3 4 5 6 100V AC (50/60Hz) 200V AC (50/60Hz) 110V AC (50/60Hz) 220V AC (50/60Hz) 24V DC 12V DC VP4 VQ VQ4 Wiring Specifications VQZ The lead wires are connected to the valve as shown below. Connect each to the power supply side.

55 60 65 70 75 35 40 45 50 55 60 65 70 75 80 D 30 35 40 45 50 55 30 35 40 45 50 55 30 35 40 45 Mounting bolt part no.

D-H7 type On the head side of the bore size 20, 25, 32, 40, 50, 63 D-A9/C7/C8 types On the head side of the bore size 20, 32, 40 D-G5/K5/B59W types On the head side of the bore size 20, 25, 32, 50, 63 D-B5/B6 types On the head side of the bore size 20, 25, 32, 50, 63, 80, 100 and the rod side of the bore size 20, 25, 32 -X Technical Data 373 CG3 Series Minimum Stroke for Auto Switch

14 18 (6.3) B1 A1 5 6 17.7 14.2 A6 B6 B1 A1 10.2 2 1 B3 A3 (5.7) 15 16 11 30.7 45 - 115 I/O No.

(mm) Stroke range (mm) Special cap bolt 32 5 to 50 50 33 60 43 5.5 8 48 56 65 75, 100 60 43 M FV 40 5 to 50 56.5 39.5 66.5 49.5 5.5 8 54 62 72 75, 100 66.5 49.5 FT L B + Stroke A + Stroke 50 10 to 50 58.5 40.5 68.5 50.5 6.6 9 67 76 89 75, 100 68.5 50.5 4 x FD FX FZ Bore size (mm) Stroke range (mm) L L1 M 32 5 to 50 17 38.5 34 75, 100 40 5 to 50 17 38.5 40 75, 100 L1 50 10 to 50 18 43.5 50

LAT3M-50 0 to 50 LAT3F-10 0 to 10 LAT3F-20 0 to 20 0.005 LAT3F-30 0 to 30 LAT3F-50 0 to 50 This determines the condition for when the INF signal is activated. The INF signal turns ON when the pushing force generated by the Card Motor exceeds the 0.5 to 5.0 set value.

LAT3M-50 0 to 50 LAT3F-10 0 to 10 LAT3F-20 0 to 20 0.005 LAT3F-30 0 to 30 LAT3F-50 0 to 50 This determines the condition for when the INF signal is activated. The INF signal turns ON when the pushing force generated by the Card Motor exceeds 0.5 to 5.0 the set value.

Since Series CHM does not have an air release valve, release air from components other than the cylinder (e.g. from piping, etc.). 20 + 50 n 2 2 20 65 10 D-H7LF (n = 2, 4, 6 ) D-B5 D-B6 D-G5NTL 15 + 50 n 2 2 15 75 10 2. When operating a cylinder for the first time, be sure to release the air at low pressure.

, 50, 75, 100, 125, 150, 200 MB 40, 50, 63 25, 50, 75, 100, 125, 150, 200, 250, 300 Please consult with SMC for strokes which exceed the standard stroke length.

20 100V CE1 PLC D-C73C 5 to 40 24V DC AC DC CE2 D-C80C IC circuit, Relay, PLC 50 24Vor less D-B53,A33 5 to 50 24V DC PLC ML2B 5 to 50 24V DC D-B54 D-A34 D-A44 5 to 25 100V AC ML1C 5 to 12.5 200V AC AC DC 50 Relay, PLC 24Vor less REA D-B64 25 100V AC 12.5 200V AC REC 5 to 40 2 color** D-B59W 24V DC RHC * Use contact protection box when using "D-C7" or "D-C8" type in the following conditions

However, the piston speed at this time should be adjusted to the minimum speed. 15 65 10 (n = 2, 4, 6 ) 65 + 50 (n 2) (n = 2, 3, 4, 5 ) 20 + 50 n 2 2 20 65 10 D-H7LF (n = 2, 4, 6 ) 15 + 50 n 2 2 D-B5 D-B6 15 75 10 (n = 2, 4, 6 ) Mounting 75 + 55 (n 2) (n = 2, 3, 4, 5 ) 20 + 50 n 2 2 Caution D-B59W 20 75 15 (n = 2, 4, 6 ) 1.

BBA3: For D-B5/B6/G5/K5 BBA4: For D-C7/C8/H7 D-G5BAL/H7BAL switch is set on the cylinder with the stainless steel screws above when shipped.

BBA3: For D-B5/B6/G5/K5 BBA4: For D-C7/C8/H7 D-G5BAL/H7BAL switch is set on the cylinder with the stainless steel screws above when shipped.

D-C8 D-A5 D-A6 80 24 3 wire 3 wire 10 50 D-A59W 80 25 D-C73C D-C80C 14 53 40 162 50 166 D-B5 D-B6 22 78 Reed switch D-A3lC 63 184 Reed switch 80 D-B59W 20 210 76 100 D-A3 232 116 40 D-A4 160 114 50 164 D-A3lA D-A44A 110 D-A44C 63 182 2 wire 80 11 50 208 3 wire 100 D-H7 13 57 230 4 wire 2 wire D-J5 71 21 13 56 Solid state switch 2 wire 3 wire D-K5 81 23 18 68 D-F5 Solid state switch 3 wire

Minimum Stroke for Auto Switch Mounting (mm) No. of auto switches mounted 2 Different sides Auto switch model Same side n Different sides 1 Same side D-C7 D-C80 15 50 50 + 45 (n 2) 10 n 2 2 15 + 45 ( ) (n = 2, 4, 6) D-H7 D-H7W D-H7BAL D-H7NF 15 60 60 + 45 (n 2) 10 D-C73C D-C80C D-H7C n 2 2 15 + 50 ( ) (n = 2, 4, 6) 65 + 50 (n 2) 15 65 10 n 2 2 D-B5 D-B64 15 + 50 ( ) (n = 2, 4, 6) 15

0.5 1 5 10 20 50 0.5 1 5 10 20 50 Load (kN) Load (kN) Bore size 80 B rod C rod 2000 6 4 8 3 7 5 1 5 2 4 8 3 7 6 1 2 1000 Stroke (mm) 500 100 50 1 5 10 20 50 1 5 10 20 50 Load (kN) Load (kN) Bore size 100 B rod C rod 4 8 8 3 3 7 7 5 4 5 2000 6 6 1 2 1 2 1000 Stroke (mm) 500 100 50 1 5 10 20 50 100 1 5 10 20 50 100 Load (kN) Load (kN) 28 Series CH2E/CH2F/CH2G/CH2H Technical Data 3 Relationship

Minimum Stroke for Auto Switch Mounting (mm) No. of auto switches mounted 2 Different sides Auto switch model Same side n Different sides 1 Same side D-C7 D-C80 15 50 + 45 (n 2) 50 10 n 2 2 15 + 45 ( ) (n = 2, 4, 6) D-H7 D-H7W D-H7BAL D-H7NF 15 60 + 45 (n 2) 60 10 D-C73C D-C80C D-H7C n 2 2 15 + 50 ( ) (n = 2, 4, 6) 65 + 50 (n 2) 15 65 10 n 2 2 D-B5 D-B64 15 + 50 ( ) (n = 2, 4, 6) 15

"n" pcs. 90 75 120 Same side (n 4) 2 (n 4) 2 (n 2) 2 15 + 50 90 + 50 120 + 50 Different sides D-B5, D-B6 n = 2, 4, 6, 8 n = 4, 8, 12, 16 n =4 , 8, 12, 16 120 + 5 (n 2) 75 + 50 (n 2) 90 + 50 (n 2) Same side n = 2, 4, 6, 8 n = 2, 3, 4 n = 2, 4, 6, 8 10 1 pc. 120 90 Different sides 20 90 120 2 pcs. "n" pcs.