For details, refer to page 365. 329 Series CHA How to Mount and Move the Auto Switch Solid state D-F59, D-F5P D-J59, D-J51, D-F5BAL D-F59W, D-F5PW, D-J59W D-F59F, D-F5NTL Reed D-A53, D-A54, D-A56, D-A64, D-A67 D-A59W Solid state D-M9N(V), D-M9P(V), D-M9B(V) D-M9NW(V), D-M9PW(V), D-M9BW(V) D-M9NA(V), D-M9PA(V), D-M9BA(V) Auto switch mounting

The ZCUK series is a non-rotating free mount cylinder for vacuum applications. The ZCUK was created by providing a vacuum passage in the rod of the CUK cylinder to enable a vacuum pad to be installed on the end of the rod. A guide is provided as standard equipment. Vacuum pads are available with pad diameters of ø2 to ø50. Cap or rod piping is available to the rod side. Series ZCUK is available

The MXQ precision slide is ideal for applications requiring closely held parallelism and perpendicular specifications. The table and bearing guide are integrated into one precisely machined part made of hardened stainless steel. This minimizes tolerance stack-up associated with multiple part assemblies, and affords height tolerances of +/-0.05mm. The bearing is a recirculating linear guide

The MXQ precision slide is ideal for applications requiring closely held parallelism and perpendicular specifications. The table and bearing guide are integrated into one precisely machined part made of hardened stainless steel. This minimizes tolerance stack-up associated with multiple part assemblies, and affords height tolerances of +/-0.05mm. The bearing is a recirculating linear guide

The MXQ precision slide is ideal for applications requiring closely held parallelism and perpendicular specifications. The table and bearing guide are integrated into one precisely machined part made of hardened stainless steel. This minimizes tolerance stack-up associated with multiple part assemblies, and affords height tolerances of +/-0.05mm. The bearing is a recirculating linear guide

The new style MGP has a shorter guide rod and thinner plate resulting in a weight reduction of up to 17% over the original MGP.  The series is designed for high side load applications found in material handling, lifting and stopping. The cylinder utilizes an ultra-compact design by incorporating the cylinder body as part of the guide body. As the stroke length increases, so does the bearing

The MXQ precision slide is ideal for applications requiring closely held parallelism and perpendicular specifications. The table and bearing guide are integrated into one precisely machined part made of hardened stainless steel. This minimizes tolerance stack-up associated with multiple part assemblies, and affords height tolerances of +/-0.05mm. The bearing is a recirculating linear guide

The MXQ precision slide is ideal for applications requiring closely held parallelism and perpendicular specifications. The table and bearing guide are integrated into one precisely machined part made of hardened stainless steel. This minimizes tolerance stack-up associated with multiple part assemblies, and affords height tolerances of +/-0.05mm. The bearing is a recirculating linear guide

, M9P, M9B, M9NV, M9PV, M9BV D-M9NW, M9PW, M9BW, M9NWV, M9PWV, M9BWV D-M9NA, M9PA, M9BA, M9NAV, M9PAV, M9BAV Reed D-A90, A93, A96, A90V, A93V, A96V Standard 1.

D-B59W Band Mounting Style . D-A79W Rail Mounting Style . Solid State Switches . General Purpose Type. D-H7A1/D-H7A2/D-H7B Band Mounting Style . D-G59/D-G5P/D-K59 Band Mounting Style. D-H7C Band Mounting Style. D-F79/D-F7P/D-J79 Rail Mounting Style. D-F7NV/D-F7PV/D-F7BV Rail Mounting Style . D-J79C Rail Mounting Style. D-M9N(V)/D-M9P(V)/D-M9B(V) Direct Mounting Style .

(V) / D-M9P(V) / D-M9B(V) D-M9NW(V) / D-M9PW(V) / D-M9BW(V) D-M9NA(V) / D-M9PA(V) / D-M9BA(V) D-M90(V) / D-A93(V) / D-A96(V) D-P3DWSC / D-P3DWSW D-P3DW / L / Z 210 211 212 213 214 215 Warranty and Operating Instructions Mounting and Auto Switches Made to Order 181 Standard and Long Stroke Auto Switch Selection Series (N)CQ2 Applicable Auto Switches Standard Load voltage Auto switch model

Auto Switch Specifications Grommet PLC: Abbreviation of Programmable Logic Controller D-M9, D-M9V (With indicator light) 2-wire load current is reduced (2.5 to 40 mA) Lead-free UL certified (style 2844) lead cable is used. D-M9P D-M9NV D-M9B D-M9N D-M9PV D-M9BV Auto switch part no.

D-M9NW(V), D-M9PW(V), D-M9BW(V), D-M9NA(V)L, D-M9PA(V)L, D-M9BA(V)L Reed D-A90(V), D-A93(V), D-A96(V) Solid state D-M9N(V), D-M9P(V), D-M9B(V), D-M9NW(V), D-M9PW(V), D-M9BW(V), D-M9NA(V), D-M9PA(V), D-M9BA(V) Reed D-A90(V), D-A93(V), D-A96(V) How to Mount and Move the Auto Switch How to Mount and Move the Auto Switch Cylinder tube Auto switch mounting screw Watchmakers

D-F7NV/D-F7PV/D-F7BV Rail Mounting Style . D-J79C Rail Mounting Style. D-F59/D-F5P/D-J59/D-J51 Tie-rod Mounting Style . D-G39C/D-K39C Tie-rod Mounting Style. D-M9N(V)/D-M9P(V)/D-M9B(V) Direct Mounting Style . D-Y59A, B/D-Y69A, B/D-Y7P(V) Direct Mounting Style . D-M5N/D-M5P/D-M5B Direct Mounting Style. D-F9G/D-F9H Normally Closed Direct Mounting Style.

D-M9N(V)/D-M9P(V)/D-M9B(V) Auto Switch Specifications Grommet PLC: Programmable Logic Controller 2-wire load current is reduced (2.5 to 40 mA).

/C8 D-C73C/C80C D-B5/B6 D-B59W D-A3/A4 D-A3A/A44A D-A3C/A44C D-A7/A8 D-A7H/A80H D-A73C/A80C D-A79W D-A5/A6 D-A59W D-A9 D-A9V D-Z7/Z8 D-H7 D-H7C D-H7BAL D-H7F D-H7W D-G5/K5 D-G5BAL D-G59F D-G5NTL D-G5W/K59W D-G39/K39 D-G39A/K39A D-F7/J7 D-J79C D-F7F D-F7BAL D-F7BAVL D-F7V D-F7NTL D-F7W (V) D-F5/J5 D-F5BAL D-F5W/J59W D-F5F D-F5NTL D-G39C/K39C D-M9 D-M9V D-F9W D-F9WV D-F9BAL D-Y59A/Y7P/Y59B

Applicable Cylinder Series: CDQP2, CDQP2lll-lS/-lT (Axial piping) (mm) D-A7lH D-A80H D-F7l D-J79 D-F7lW D-J79W D-F7BAL D-F79F D-F7NTL U 26.5 29.5 31.5 34.5 38.5 42 48 54.5 64.5 74.5 Auto switch model D-A9l D-A9lV D-M9l D-M9lV D-M9lW D-M9lWV D-M9lAL D-M9lAVL D-F7lV D-F7lWV D-F7BAVL D-A7l D-A80 D-A73C D-A80C D-J79C D-A79W D-P4DWL Bore size U 26 29 31 34 38 41.5 47.5 54 64 74 U 23 26 28 31 35

(M)(L)(Z) Solid state auto switch M9P(M)(L)(Z) D-M9P(M)(L)(Z) M9B(M)(L)(Z) D-M9B(M)(L)(Z) A90(L) D-A90(L) Reed auto switch (Not applicable to flange size 16) A93(M)(L)(Z) D-A93(M)(L)(Z) M9// Without auto switch (with magnet) * Standard lead wire length is 0.5 m.

Auto Switch Mounting Height (mm) Auto switch model D-A9 D-M9 D-M9W D-M9A D-B5 D-B64 D-B59W D-G5 D-K59 D-G5NT D-G5W D-K59W D-G59F D-F5 D-J59 D-F5W D-J59W D-F59F D-F5NT Note 2) D-Z7 D-Z80 D-Y59 D-Y7P D-Y7W D-A3C D-G39C D-K39C D-A44C D-Y69 D-Y7PV D-Y7WV D-A3 D-G39 D-K39 D-A44 D-A5 D-A6 D-A59W D-A9V D-M9V D-M9WV D-M9AV Note 2) D-P4DW D-P3DW Hs Ht Hs Ht Hs Hw Hs Ht Hs Ht Hs Ht Hs Ht Hs Ht Hs Hs

Unit: g Model D-M9N D-M9B D-M9P 0.5 8 7 8 Lead wire length m 3 41 38 41 Auto Switch Dimensions Auto Switch Internal Circuit D-M9 M2.5 x 4l mounting hole Slotted set screw Indicator light D-M9B, N, P D-M9N DC(+) Brown 2.6 Main circuit of switch Main circuit of switch Main circuit of switch OUT Black 2.7 2.8 4 22 DC(-) Blue 3.2 D-M9N, P (3-wire) D-M9P Most sensitive position 6 DC(+) Brown 22