L Y59AL 5m . Z Y59AZ Solid state switches marked "" are produced upon receipt of order. Note 1) Perpendicular electrical entry is not available for 50 and 63.
Straight type Stroke Air supply unit Note 1) 200 250 300 350 400 450 500 600 1000 200mm 250mm 300mm 350mm 400mm 450mm 500mm 600mm 1000mm Qty. None 1 set 2 sets Description Symbol Nil AS AW A unit (Air system 1) Note 1) Air supply unit, 1 set breakdown: Supply block (slide table side) 1pc. Supply ring (plate side) 2pcs. The maximum produceable stroke is 5000mm.
. @4, @6, @7, @8, @9, #0 Wear ring A 6, 10: Not available Special resin CY3R10-PS 10 CY3R10-PS Wear ring B Special resin CY3R15-PS 15 20 25 32 40 50 63 CY3R15-PS CY3R20-PS CY3R25-PS CY3R32-PS CY3R40-PS CY3R50-PS CY3R63-PS Wear ring C Special resin CY3R20-PS CY3R25-PS Piston seal NBR Set of left nos. @4, @5, @6, @7, @8, @9, #0 CY3R32-PS Lubretainer 6: Not available Special resin CY3R40-PS
Grommet (NPN equivalent) Y69A Y7PV Y69B Y7NWV Y7PWV Y7BWV 100 V 24 V 12 V Z73 Y59A Y7P Y59B Y7NW Y7PW Y7BW 3-wire (NPN) 2-wire Relay, PLC RB 5 V, 12 V IC circuit 3-wire (PNP) J 2-wire 12 V Relay, PLC 24 V Grommet 3-wire (NPN) 3-wire (PNP) IC circuit 5 V, 12 V Diagnostic indication (2-color indication) D2-wire 12 V Lead wire length symbols: 0.5 mNil (Example) Y59A 3 m L (Example) Y59AL
Piping: Standard, Bore Size: 40mm, Port Thread: (M5 Thread-6~15mm)(Rc-20~63mm), Stroke: 250mm
Type: Rodless Cylinder, Cylinder Inner Diameter(Ø): 40, Stroke(mm): 250, Max.
Y69A Y7PV Y69B Y7NWV Y7PWV Y7BWV 100 V 24 V 12 V Z73 Y59A Y7P Y59B Y7NW Y7PW Y7BW 3-wire (NPN) 2-wire Relay, PLC 5 V, 12 V IC circuit 3-wire (PNP) 2-wire 12 V Relay, PLC 24 V Grommet 3-wire (NPN) 3-wire (PNP) Diagnostic indication (2-color indication) IC circuit 5 V, 12 V 2-wire 12 V Lead wire length symbols: 0.5 mNil (Example) Y59A 3 m L (Example) Y59AL 5 m Z (Example) Y59AZ Since
V Z73 Y59A Y7P Y59B Y7NW Y7PW Y7BW Relay, PLC 3-wire (NPN) 2-wire Y69A Y7PV Y69B Y7NWV Y7PWV Y7BWV IC circuit 5 V, 12 V 3-wire (PNP) 12 V 2-wire 3-wire (NPN) 3-wire (PNP) Relay, PLC IC circuit 24 V Grommet 5 V, 12 V Diagnostic indication (2-color indication) 2-wire 12 V Water resistant (2-color indication) Y7BA Lead wire length symbols: 0.5 m Nil (Example) Y59A 3 m L (Example) Y59AL
Z73 Y59A Y7P Y59B Y7NW Y7PW Y7BW 3-wire (NPN) 2-wire Y69A Y7PV Y69B Y7NWV Y7PWV Y7BWV 100 V or less IC circuit 5 V, 12 V 3-wire (PNP) IC circuit 2-wire 12 V Relay, PLC 24 V Grommet 3-wire (NPN) 3-wire (PNP) 5 V, 12 V Diagnostic indication (2-color indication) 2-wire 12 V Lead wire length symbols: 0.5 m Nil (Example) Y59A 3 m L (Example) Y59AL 5 m Z (Example) Y59AZ Since there are
Lead wire length symbols: 0.5 m Nil (Example) Y59A 3 m L (Example) Y59AL 5 m Z (Example) Y59AZ Solid state auto switches marked with are produced upon receipt of order. Auto switches are shipped together (not assembled).
Lead wire length symbols: 0.5 m Nil (Example) Y59A 3 m L (Example) Y59AL 5 m Z (Example) Y59AZ Auto switches marked with a symbol are produced upon receipt of order. Note) No need to add -X61 at the end of the part number for the flexible lead wire for D-Y type auto switch, because it adopts flexible lead wire as standard.
Y69A Y7PV Y69B Y7NWV Y7PWV Y7BWV 100 V 24 V 12 V Z73 Y59A Y7P Y59B Y7NW Y7PW Y7BW 3-wire (NPN) 2-wire Relay, PLC 5 V, 12 V IC circuit 3-wire (PNP) 2-wire 12 V Relay, PLC 24 V Grommet 3-wire (NPN) 3-wire (PNP) Diagnostic indication (2-color indication) IC circuit 5 V, 12 V 2-wire 12 V Lead wire length symbols: 0.5 mNil (Example) Y59A 3 m L (Example) Y59AL 5 m Z (Example) Y59AZ Since
Lead wire length symbols: 0.5 m Nil (Example) Y59A 3 m L (Example) Y59AL 5 m Z (Example) Y59AZ Auto switches marked with a symbol are produced upon receipt of order. Note) No need to add -X61 at the end of the part number for the flexible lead wire for D-Y type auto switch, because it adopts flexible lead wire as standard.
IC circuit No 3 wire (NPN) 3 wire (PNP) Y69A Y59A 5V, 12V IC circuit Y7PV Y7P 2 wire Y69B Y59B 12V Solid state switch Relay, PLC 24V 3 wire (NPN) 3 wire (PNP) Y7NWV Y7NW Yes Grommet 5V, 12V Diagnostic indication (2 color indicator) IC circuit Y7PWV Y7PW Y7BWV Y7BW 12V 2 wire Water resistant (2 color indicator) Y7BA Lead wire length symbols 0.5m Nil (Example) Y59A 3m L (Example) Y59AL
L (Example) Y59AL 5m . Z (Example) Y59AZ 1 Compact Hydraulic Cylinder: 10MPa Series CHKDB Specifications Light and compact aluminum body. Auto switches can be mounted. Auto switch mounting does not affect overall length. A wide range of operating pressures, bore sizes, and standard strokes make more selections possible to suit your individual needs.
L (Example) Y59AL 5m . Z (Example) Y59AZ 13 Compact Hydraulic Cylinder: 16MPa Series CHKGB Specifications Light and compact aluminum body. Action Double acting/Single rod type Fluid Hydraulic fluid Auto switch can be mounted. Nominal pressure 16MPa Auto switch mounting does not affect overall length.
Magnet: Built-in, Mounting: -, Bore Size: 100mm, Thread Type: -, Stroke: 75mm, Rod End Nut: Female Thread, Auto Switch: Y59AL--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, 3M, Lead Wire or Prewired Connector: -, Number: -
Magnet: Built-in, Mounting: -, Bore Size: 40mm, Thread Type: -, Stroke: 100mm, Rod End Nut: Male Thread, Auto Switch: Y59AL--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, 3M, Lead Wire or Prewired Connector: -, Number: -