SMC Corporation of America
Elite Part Number Search
Search Results "CY1L10H-300B-A73"

Bore Size: 25mm, Port Thread: Rc (or M Thread for 6 to 15 Bore), Magnetic Holding Force: H (Large Holding Force), Stroke: 300mm, Adjuster: B (Shock Absorbers (2 pcs)), Auto Switch: A73--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Vertical

Bore Size: 15mm, Port Thread: Rc (or M Thread for 6 to 15 Bore), Magnetic Holding Force: L (Small Holding Force), Stroke: 300mm, Adjuster: B (Shock Absorbers (2 pcs)), Auto Switch: A73--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Vertical

Cylinder: w/Auto Switch/Housing Mount, Model: Air-hydro Style (Except Ø10), Bore Size: 5/8 Inch, Stroke: 3 Inch, Cushion: Shock Absorbers (2 pcs), Auto Switch: A73--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Vertical, 0.5M, Number: -

Cylinder: w/Auto Switch/Housing Mount, Model: Non-lube, Bore Size: 5/8 Inch, Stroke: 3 Inch, Cushion: Shock Absorbers (2 pcs), Auto Switch: A73--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Vertical, 0.5M, Number: -

Cylinder: w/Auto Switch/Housing Mount, Model: Non-lube, Bore Size: 1 Inch, Stroke: 3 Inch, Cushion: Shock Absorbers (2 pcs), Auto Switch: A73--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Vertical, 0.5M, Number: -

Cylinder: w/Auto Switch/Plate Mount, Model: Non-lube, Bore Size: 5/8 Inch, Stroke: 3 Inch, Cushion: Shock Absorbers (2 pcs), Auto Switch: A73--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Vertical, 0.5M, Number: -

Cylinder: w/Auto Switch/Plate Mount, Model: Non-lube, Bore Size: 1 Inch, Stroke: 3 Inch, Cushion: Shock Absorbers (2 pcs), Auto Switch: A73--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Vertical, 0.5M, Number: -

Bore Size: 25mm, Port Thread: Rc (or M Thread for 6 to 15 Bore), Magnetic Holding Force: Small Holding Force, Stroke: 300mm, Adjuster: Shock Absorbers (2 pcs), Auto Switch: A73--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Vertical, Lead Wire or Prewired Connector: -, Number: -

Bore Size: 32mm, Port Thread: Rc (or M Thread for 6 to 15 Bore), Magnetic Holding Force: Large Holding Force, Stroke: 300mm, Adjuster: Shock Absorbers (2 pcs), Auto Switch: A73--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Vertical, Lead Wire or Prewired Connector: -, Number: -

Bore Size: 15mm, Port Thread: Rc (or M Thread for 6 to 15 Bore), Magnetic Holding Force: Large Holding Force, Stroke: 300mm, Adjuster: Shock Absorbers (2 pcs), Auto Switch: A73--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Vertical, Lead Wire or Prewired Connector: -, Number: -

Bore Size: 25mm, Port Thread: Rc (or M Thread for 6 to 15 Bore), Magnetic Holding Force: Large Holding Force, Stroke: 300mm, Adjuster: Shock Absorbers (2 pcs), Auto Switch: A73--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Vertical, Lead Wire or Prewired Connector: -, Number: -

Bore Size: 15mm, Port Thread: Rc (or M Thread for 6 to 15 Bore), Magnetic Holding Force: Small Holding Force, Stroke: 300mm, Adjuster: Shock Absorbers (2 pcs), Auto Switch: A73--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Vertical, Lead Wire or Prewired Connector: -, Number: -

Bore Size: 15mm, Port Thread: Rc, Magnetic Holding Force: Large Holding Force, Stroke: 300mm, Adjuster: B [Shock Absorbers (2 pcs)], Auto Switch: A73--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Vertical, Lead Wire or Prewired Connector: -, Number: -

Bore Size: 25mm, Port Thread: Rc, Magnetic Holding Force: Large Holding Force, Stroke: 300mm, Adjuster: B [Shock Absorbers (2 pcs)], Auto Switch: A73--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Vertical, Lead Wire or Prewired Connector: -, Number: -

Bore Size: 10mm, Port Thread: Rc, Magnetic Holding Force: Large Holding Force, Stroke: 300mm, Adjuster: B [Shock Absorbers (2 pcs)], Auto Switch: A73--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Vertical, Lead Wire or Prewired Connector: -, Number: -

Bore Size: 32mm, Port Thread: Rc, Magnetic Holding Force: Large Holding Force, Stroke: 300mm, Adjuster: B [Shock Absorbers (2 pcs)], Auto Switch: A73--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Lead Wire, Vertical, Lead Wire or Prewired Connector: -, Number: -

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

With no external leakage, the CY series can be used in many diverse environments. Magnetically coupled cylinders have a wide range of applications, and save mounting space. Loads and moments are possible through the use of integrated guides. A variety of guides can be used to achieve the necessary accuracy or allowable moment needed for your application. CY is available in 9 bore sizes,

With no external leakage, the CY series can be used in many diverse environments. Magnetically coupled cylinders have a wide range of applications, and save mounting space. Loads and moments are possible through the use of integrated guides. A variety of guides can be used to achieve the necessary accuracy or allowable moment needed for your application. CY is available in 9 bore sizes,

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, RODLESS, ACTUATOR, CY1H/CY1L GUIDED CYLINDER, EE, 10MM CY1H/CY1L DBL-ACT A/S, 3.52739 lb, Bore size (mm)ModelAllowable load mass (Wv)(kg)Maximum operating pressure (Pv)(MPa)10CY1L10H2.70.55