D-A90(V) AC DC AC DC 100V or less 20mA AC DC 24V or less 50mA Maximum load current Contact protection box OUT () Brown [Red] Reed switch Reed switch Reed switch Contact protection circuit Internal voltage drop CD-P11 OUT ( ) Blue [Black] CD-P12 D-A93, A93V, D-A96, A96V (with indicator light) D-A93(V) D-A93 In-line D-A93V Perpendicular D-A96 In-line D-A96V Perpendicular Relay, PLC IC circuit
Internal resistance 1 or less (Including 3m lead wire) D-A93V/D-A96V (With indicator light) LED Brown(Red) Contact protection box OUT(+) Brown(Red) D-A93V D-A96V Resistance Auto switch model number Reed switch Application Relay/PLC IC circuit Zener diode to CD-P11 Load voltag 100V AC 24V DC 4 to 8V DC OUT() Blue(Black) CD-P12 Blue(Black) Max. load current and load current range 5 to 20mA
Applicable models D-A73, A73H, A73C, C73, C73C, E73A, Z73, R73 D-97, 93A, A93, A93V D-A33, A34, A33A, A34A, A44, A44A D-A53, A54, B53, B54 2) However, when using a 2 color indication auto switch (DA79W, A59W, B59W), be aware that the switch will constantly remain ON if the connections are reversed.
(Example) CHDAWB50-100m Nil N R H Both sides Without cushion With rod cushion With head cushion Cushion Cylinder stroke (mm) Refer to the standard stroke table on page 333. Applicable Auto Switches: Refer to pages 347 to 406 for further details on each auto switch.
A90 A90V No Reed switch Solid state switch 2 wire 24V A93 A93V Grommet 100V 12V Yes 3 wire (NPN equiv.)
Applicable models D-A73, A73H, A73C, C73, C73C, E73A, Z73, R73 D-97, 93A, A93, A93V D-A33, A34, A33A, A34A, A44, A44A D-A53, A54, B53, B54 2) However, when using a 2 color indication auto switch (DA79W, A59W, B59W), be aware that the switch will constantly remain ON if the connections are reversed.
Applicable models: D-A73, A73H, A73C, C73, C73C, Z73 D-A93, A93V D-A33, A34, A33A, A34A, A44, A44A D-A53, A54, B53, B54 2) However, when using a two color indication auto switch (DA79W, A59W, B59W), be aware that the switch will constantly remain ON if the connections are reversed.
Applicable model: D-93, A93V
When a load, such as a relay or solenoid valve, which generates surge is directly driven, use a type of switch with a built-in surge absorbing element. 2) Although wire length does not affect switch function, use wiring 100m or shorter. 5. Take precautions for the internal voltage drop of the switch.
Applicable model: D-93, A93V
Applicable model: D-93, A93V