Mounting: Through Hole, Bore Size: 32mm, Stroke: 5mm, Option: Standard (Rod End Female Thread), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Rated Voltage: 24 VDC, Electrical Entry: M Plug Connector With Lead Wire, Surge Voltage Suppressor: Light/Surge Voltage Suppressor, Manual Override
Mounting: Through Hole, Bore Size: 32mm, Stroke: 100mm, Option: Standard (Rod End Female Thread), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Rated Voltage: 24 VDC, Electrical Entry: M Plug Connector With Lead Wire, Surge Voltage Suppressor: Light/Surge Voltage Suppressor, Manual Override
Mounting: Through Hole, Bore Size: 32mm, Stroke: 75mm, Option: Standard (Rod End Female Thread), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Rated Voltage: 24 VDC, Electrical Entry: M Plug Connector With Lead Wire, Surge Voltage Suppressor: Light/Surge Voltage Suppressor, Manual Override
Mounting: Through Hole, Bore Size: 32mm, Stroke: 15mm, Option: Rod End Male Thread, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Rated Voltage: 24 VDC, Electrical Entry: M Plug Connector With Lead Wire, Surge Voltage Suppressor: Light/Surge Voltage Suppressor, Manual Override: -, Piping
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~50, End Locking: No, Valves: Presence, Operating Pressure(MPa): 0.15~0.7, Support bracket: Through-hole
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~50, End Locking: No, Valves: Presence, Operating Pressure(MPa): 0.15~0.7, Support bracket: Through-hole
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~50, End Locking: No, Valves: Presence, Operating Pressure(MPa): 0.15~0.7, Support bracket: Through-hole
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~50, End Locking: No, Valves: Presence, Operating Pressure(MPa): 0.15~0.7, Support bracket: Through-hole
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 40, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~50, End Locking: No, Valves: Presence, Operating Pressure(MPa): 0.15~0.7, Support bracket: Through-hole
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~50, End Locking: No, Valves: Presence, Operating Pressure(MPa): 0.15~0.7, Support bracket: Through-hole
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~50, End Locking: No, Valves: Presence, Operating Pressure(MPa): 0.15~0.7, Support bracket: Through-hole
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~50, End Locking: No, Valves: Presence, Operating Pressure(MPa): 0.15~0.7, Support bracket: Through-hole
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~50, End Locking: No, Valves: Presence, Operating Pressure(MPa): 0.15~0.7, Support bracket: Through-hole
Refer to pages 15-8-3 and 15-8-4 for Safety Instructions and Common Precautions on the products mentioned in this catalog, and refer to pages 15-8-6 to 15-8-8 for Precautions on every series. 15-10-1 2 Series ASP How to Order ASP 3 30F 01 06 S Pilot check valve With seal Body size Applicable tubing O.D.
ASP with PHot Check Valve enes How to Order ASP S;:30F 0,1 ,0615 t .. , I .""~" Pilot ch".J Body size e diameter size '3: 1/8 standard Applicable tube outsid Millimeter size Inch 06 07 01/4" I 06 '~ 1/4 standard 5 3/8 standard 6 1/2 standard 08 08 05/16" .09 I 10 010 ~1 1 * 03/8' L12 " 012 1211/2" ;~ Type I 3 I Untversal Port size . +' ) PH otport 4' ; ~Y!l1bOl Cylir!
(Case) M9NW 1mM (Case) M9NWM 3mL (Case) M9NWL 5mZ (Case) M9NWZ *Note 2) When 2 auto-switches are specified they are assembled for shipping. Otherwise, the switch(es) is/are included in the package separately. duAro1duAro2RS003NRS005NRS005LRS007NRS007L *Note1 3-2.
(Case) M9NW 1mM (Case) M9NWM 3mL (Case) M9NWL 5mZ (Case) M9NWZ *Note 2) This product can be mounted on the NEXTAGE KAWADA ROBOTICS CORPORATION. 3-2.
wire (NPN) 24V F79W F7PW Yes 5V,12V IC Diagnostic indication (2 color) 3 wire (PNP) F9PW F9BW F9BA F9PWV F9BWV J79W F7BA F7NT F79F F7BWV 12V Grommet 2 wire Water resistant (2 color) With timer Diagnostic indication (2 color) 3 wire (NPN) IC 5V,12V V 4 wire (NPN) Latch with diagnostic output (2 color) F7LF v V V PLC: Programmable Logic Controller Lead wire length symbol 0.5m(Example) A80C 5mZ
C73C 5mZ e.g.) C73CZ 3mL C73CL NoneN C73CN Solid state switches marked with are manufactured upon receipt of order. 1.3-52 Low Friction Style: Double Acting Single Rod Series CJ2Q Application Example Specially designed to keep friction of the piston to a minimum. Suitable for contact-pressure control requiring smooth operation at low pressures.