SMC Corporation of America
Elite Part Number Search
Search Results "CJ2WB16-125AZ"

Magnet: None, Mounting: Basic Style, Bore Size: 16mm, Stroke: 15mm, Cushion: Air Cushion, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, Made-to-Order: -

Magnet: None, Mounting: Basic Style, Bore Size: 16mm, Stroke: 30mm, Cushion: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, Made-to-Order: -

Magnet: None, Mounting: Basic Style, Bore Size: 16mm, Stroke: 30mm, Cushion: Air Cushion, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, Made-to-Order: -

Magnet: None, Mounting: Basic Style, Bore Size: 16mm, Stroke: 45mm, Cushion: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, Made-to-Order: -

Magnet: None, Mounting: Basic Style, Bore Size: 16mm, Stroke: 60mm, Cushion: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, Made-to-Order: -

Magnet: None, Mounting: Basic Style, Bore Size: 16mm, Stroke: 60mm, Cushion: Air Cushion, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, Made-to-Order: -

Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1~0.7, Cushion: Air cushion, Auto Switches: Without auto switch

Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1~0.7, Cushion: Rubber cushion, Auto Switches: Without auto

Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1~0.7, Cushion: Rubber cushion, Auto Switches: Without auto

Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1~0.7, Cushion: Rubber cushion, Auto Switches: Without auto

Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 45, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1~0.7, Cushion: Air cushion, Auto Switches: Without auto switch

Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 45, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1~0.7, Cushion: Rubber cushion, Auto Switches: Without auto

Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 60, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1~0.7, Cushion: Air cushion, Auto Switches: Without auto switch

Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 60, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1~0.7, Cushion: Rubber cushion, Auto Switches: Without auto

Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1~0.7, Cushion: Air cushion, Auto Switches: Without auto switch

Magnet: None, Mounting: Basic Style, Bore Size: 16mm, Stroke: 30mm, Cushion: Rubber Bumper, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Made-to-Order: Fluororubber Seals

Magnet: None, Mounting: Basic Style, Bore Size: 16mm, Stroke: 60mm, Cushion: Rubber Bumper, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Made-to-Order: Cold Resistant

Magnet: None, Mounting: Basic Style, Bore Size: 16mm, Stroke: 30mm, Cushion: Rubber Bumper, Auto Switch: No Switch, Lead Wire or Prewired Connector: 5m, Number: 2 pcs. (Or None in the Case of No Switch), Made-to-Order: Fluororubber Seals

Magnet: None, Mounting: Basic Style, Bore Size: 16mm, Stroke: 60mm, Cushion: Rubber Bumper, Auto Switch: No Switch, Lead Wire or Prewired Connector: 5m, Number: 2 pcs. (Or None in the Case of No Switch), Made-to-Order: Cold Resistant

The new style MGP has a shorter guide rod and thinner plate resulting in a weight reduction of up to 17% over the original MGP.  The series is designed for high side load applications found in material handling, lifting and stopping. The cylinder utilizes an ultra-compact design by incorporating the cylinder body as part of the guide body. As the stroke length increases, so does the bearing