D-A93V, D-A96, D-A96V (With indicator light) 1 or less (Including lead wire length of 3 m) Caution D-A93, D-A93V D-A96, D-A96V Auto switch model Precautions Applicable load Relay, PLC IC circuit Load voltage 100 VAC 24 VDC 4 to 8 VDC 1.
53.5 74.5 20 4.5 59 7 13 23.5 118 53.5 80 80 43.5 12 63 98 86 22 6 29 71 7 13 137 53.5 100 100 Double clevis (mm) Bore (mm) Stroke range (mm) 10 to 50 75, 100 10 to 50 75, 100 10 to 50 75, 100 Y LY LZ X W/o auto switch With auto switch A 88 98 109.5 119.5 132 142 Bore (mm) Stroke range (mm) 10 to 50 75, 100 10 to 50 75, 100 10 to 50 75, 100 CD CL CT CU CW CX CZ L 9 91.5 113 16.2 63 B 36 46
40, 50, 63, 80, 100 * Can not be used for lube type.
circuit Internal resistance Standard D-A93, D-A93V, D-A96, D-A96V (With indicator light) Auto switch model Applicable load Load voltage Load current range and Maximum load current (3) D-A90 (V) D-A93V D-A96 (V) D-A93, D-A93V Relay, PLC D-A96, D-A96V IC circuit 4 to 8 VDC Precautions Caution 24 VDC(4) 100 VAC Fix the auto switch with the existing screw installed on the auto switch body.
A96V A96 5 V Grommet Yes 100 V A93V A93 Relay, PLC 2-wire 24V 12 V 100 V or less IC circuit A90V A90 No Solid state auto switches marked are produced upon receipt of order. Table Unit/Applicable Auto Switch/Refer to pages 1719 to 1827 for detailed specifications of auto switches.
Rotary Angle Theoretical Output Operating pressure (MPa) Unit: N During unclamping (Extension end) 80 to 100 (9010) L type During unclamping (Extension end) Bore size (mm) Rod size (mm) Operating direction Piston area (cm2) 0.8 1.1 1.5 2 2 3 3.7 4.9 6 8 10.5 12.5 16.5 19.6 28 31.2 80 to 100 (9010) R type 0.3 24 33 45 60 60.8 90.2 112 149 182 243 319 380 502 596 851 948 0.5 40 55 75 100 100
V W Y 5 to 100 10 7 12 43 43.5 59 5 to 100 10 7 12 43 43.5 67 10 to 100 14 8 17 54 63 83 10 to 100 18 10.5 17 54 63 97 Note 1) The dimensions (A + stroke) and (B + stroke) for 5 mm stroke will be the same as those for 10 mm stroke.
Yes 5 V A93V A93 Grommet 12 V 100 V Relay PLC 24 V 2-wire IC circuit A90V A90 5 V,12 V 100 V or less M9NV M9N 3-wire (NPN) IC circuit 5 V 12 V M9PV M9P 3-wire (PNP) M9BV M9B 12 V 2-wire Relay PLC Yes Grommet 24 V F9NWV F9NW 3-wire (NPN) Diagnostic indication 2-color display IC circuit 5 V 12 V F9PWV F9PW 3-wire (PNP) F9BWV F9BW 2-wire 12 V . . .
(Note: Reed auto switches for 100 VAC and 100 VDC are not within the specification.
resistance D-A93, D-A93V, D-A96, D-A96V (with indicator light) D-A93, D-A93V D-A96, D-A96V Switch model Applicable load Relay, PLC IC circuit Caution Load voltage 24 VDC 4 to 8 VDC 100 VAC Operating Precautions Load current range and Maximum load current 20 mA 5 to 40 mA 5 to 20 mA Note 2) Fix the switch with appropriate screw installed on the switch body.
Applicable load IC circuit, Relay, PLC Load voltage 24 V or less 48 V or less 100 V or less AC DC AC DC AC DC Maximum load current 50 mA 40 mA 20 mA Contact protection circuit None Internal resistance 1 or less (including lead wire length of 3 m) D-A93, D-A93V, D-A96, D-A96V (With indicator light) D-A93, D-A93V D-A96, D-A96V Auto switch part no.
A90V 100 V Relay, PLC 2-wire 12 V No 100 V or less IC circuit DSolid state auto switches marked with are produced upon receipt of order.
Thus, it can be used in a Class 100 clean room.
100 + 100 (n 2) 10 CHKm Auto switches 2 pcs.
(25 to 40) 2001 to 5000 (50, 63) 25, 32, 40, 50, 63 100 to 1000 10 to 100 20, 25, 32 10 15 20 25 100 to 300 100 to 500 100 to 600 100 to 800 301 to 500 501 to 750 601 to 1000 801 to 1200 10, 20, 30, 40, 50 75, 100, 125, 150 10, 15 CY1H CXSW 10, 20, 30, 40, 50, 75, 100 125, 150, 175, 200 20, 25, 32 ML1 25 32 1001 to 1200 1001 to 1500 25, 32, 40 100 to 1000 1001 to 2000 2001 to 4000 (25, 32
Graph (7) Air Consumption of Tube or Steel Pipe (For one cycle) Graph (8) Required Air Volume of Cylinder and Piping 1000 1000 1000 1000 100 100 100 100 Air consumption (l(ANR)) Piping length (inch) Air consumption (l(ANR)) 10 10 Required air volume (l /min (ANR)) Max. piston speed (inch/s) Required air volume (l/min (ANR)) Bore size (in) Tube I.D.
CE marking D-A93, D-A93V, D-A96, D-A96V (With indicator light) Precautions Caution D-A96, D-A96V D-A93, D-A93V Auto switch model Applicable load IC circuit Relay, PLC 24 VDC Load voltage 100 VAC 4 to 8 VDC Fix the auto switch with the existing screw installed on the auto switch body.
resistance D-A93, D-A93V, D-A96, D-A96V (with indicator light) D-A93, D-A93V D-A96, D-A96V Switch model Applicable load Relay, PLC IC circuit Caution Load voltage 24 VDC 4 to 8 VDC 100 VAC Operating Precautions Load current range and Maximum load current 20 mA 5 to 40 mA 5 to 20 mA Note 2) Fix the switch with appropriate screw installed on the switch body.
75, 100, 125, 150 175, 200 75, 100, 125, 150 175, 200, 250, 300 25 Standard Non-rotating Rod Anti-lateral Load Reed switch D-A90/A90V D-A93/A93V D-A96/A96V Series CQSW 12 16 5, 10, 15, 20 25, 30 7-4-20 20 25 5, 10, 15, 20 25, 30, 35, 40 45, 50 Series CQS 12, 16 20, 25 12 16 20 25 5, 10 7-4-12 Solid state switch D-M9N/M9NV D-M9P/M9PV D-M9B/M9BV D-F9NW/F9NWV D-F9PW/F9PWV D-F9BW/F9BWV D-F9BAL