Cylinder (Tube) Inner Diameter(φ): 8, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.15~0.7, Cushion: None, Auto Switches: F8B
Magnet: Built-in Magnet, Mounting Direction: Lateral Mounting, Bore Size: 8, Stroke: 20mm, Action: Double Acting, Rod End Thread: Rod End Male Thread, Auto Switch: F8B--Solid State, Gen Purpose, 2 Wire, Vertical, Lead Wire or Prewired Connector: 3m, Number: -
Magnet: Built-in Magnet, Mounting Direction: Lateral Mounting, Bore Size: 8, Stroke: 4mm, Action: Double Acting, Rod End Thread: Rod End Male Thread, Auto Switch: F8B--Solid State, Gen Purpose, 2 Wire, Vertical, Lead Wire or Prewired Connector: 3m, Number: -
Magnet: Built-in Magnet, Mounting Direction: Lateral Mounting, Bore Size: 8, Stroke: 10mm, Action: Double Acting, Rod End Thread: Rod End Male Thread, Auto Switch: F8B--Solid State, Gen Purpose, 2 Wire, Vertical, Lead Wire or Prewired Connector: 3m, Number: -
Magnet: Built-in Magnet, Mounting Direction: Lateral Mounting, Bore Size: 8, Stroke: 10mm, Action: Double Acting, Rod End Thread: Rod End Female Thread (w/o Thread for ø4), Auto Switch: F8B--Solid State, Gen Purpose, 2 Wire, Vertical, Lead Wire or Prewired Connector: 3m, Number: -
Magnet: Built-in Magnet, Mounting Direction: Lateral Mounting, Bore Size: 8, Stroke: 20mm, Action: Double Acting, Rod End Thread: Rod End Female Thread (w/o Thread for ø4), Auto Switch: F8B--Solid State, Gen Purpose, 2 Wire, Vertical, Lead Wire or Prewired Connector: 3m, Number: -
Magnet: Built-in Magnet, Mounting Direction: Lateral Mounting, Bore Size: 8, Stroke: 25mm, Action: Double Acting, Rod End Thread: Rod End Male Thread, Auto Switch: F8B--Solid State, Gen Purpose, 2 Wire, Vertical, Lead Wire or Prewired Connector: 3m, Number: -
Magnet: Built-in Magnet, Mounting Direction: Lateral Mounting, Bore Size: 8, Stroke: 8mm, Action: Double Acting, Rod End Thread: Rod End Male Thread, Auto Switch: F8B--Solid State, Gen Purpose, 2 Wire, Vertical, Lead Wire or Prewired Connector: 3m, Number: -
Magnet: Built-in Magnet, Mounting Direction: Lateral Mounting, Bore Size: 8, Stroke: 30mm, Action: Double Acting, Rod End Thread: Rod End Male Thread, Auto Switch: F8B--Solid State, Gen Purpose, 2 Wire, Vertical, Lead Wire or Prewired Connector: 3m, Number: -
Magnet: Built-in Magnet, Mounting Direction: Lateral Mounting, Bore Size: 8, Stroke: 4mm, Action: Double Acting, Rod End Thread: Rod End Female Thread (w/o Thread for ø4), Auto Switch: F8B--Solid State, Gen Purpose, 2 Wire, Vertical, Lead Wire or Prewired Connector: 3m, Number: -
Cylinder (Tube) Inner Diameter(φ): 8, Stroke(mm): 6, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.15~0.7, Cushion: None, Auto Switches: Without
Magnet: D (Built-in Magnet), Mounting Direction: B (Lateral Mounting), Bore Size: 8, Stroke: 6mm, Action: D (Double Acting)
Cylinder (Tube) Inner Diameter(φ): 8, Stroke(mm): 6, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.15~0.7, Cushion: None, Auto Switches: Without
Magnet: D (Built-in Magnet), Mounting Direction: B (Lateral Mounting), Bore Size: 10, Stroke: 6mm, Action: D (Double Acting), Rod End Thread: Rod End Female Thread (w/o Thread for ø4), Auto Switch: F8B--Solid State, Gen Purpose, 2 Wire, Vertical, Lead Wire or Prewired Connector: L (3m)
Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 6, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1~0.7, Cushion: None, Auto Switches: F8B,
Magnet: D (Built-in Magnet), Mounting Direction: B (Lateral Mounting), Bore Size: 6, Stroke: 6mm, Action: D (Double Acting), Rod End Thread: Rod End Female Thread (w/o Thread for ø4), Auto Switch: F8B--Solid State, Gen Purpose, 2 Wire, Vertical, Lead Wire or Prewired Connector: L (3m)
Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 6, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1~0.7, Cushion: None, Auto Switches: F8B,
Bore Size: 6mm, Action: Double Acting, Finger Position: Standard, Body Option: Basic, Auto Switch: F8B--Solid State, Gen Purpose, 2 Wire, Vertical, 0.5M, Lead Wire or Prewired Connector: 3m, Number: -, Made-to-Order: -
Magnet: Built-in Magnet, Mounting Direction: Lateral Mounting, Bore Size: 6, Stroke: 6mm, Action: Double Acting, Rod End Thread: Rod End Female Thread (w/o Thread for ø4), Auto Switch: F8B--Solid State, Gen Purpose, 2 Wire, Vertical, Lead Wire or Prewired Connector: 3m, Number: -
60C, Ambient temperature: 32C Water cooled aftercooler Inlet air temperature: 180C Inlet temperature of cooling water: 30C Note 2) Series IDF Inlet air temperature: Saturated at 35C (IDF1D), saturated at 40C (IDF2D to 240D), Ambient temperature: 32C Note 3) Series IDG Inlet air temperature: Saturated at 25C, Ambient temperature: 25C Note 4) Series IDU Inlet air temperature: 60C (IDU3D to 6D