SMC Corporation of America
Elite Part Number Search
Search Results "CDS2D125TN-600-M9PSAPC"

Magnet: Built-in, Mounting: Double Clevis, Bore Size: 125mm, Port Thread: NPT, Stroke: 100mm, Rod Boot: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -

Magnet: Built-in, Mounting: Double Clevis, Bore Size: 125mm, Port Thread: NPT, Stroke: 450mm, Rod Boot: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -

Magnet: Built-in, Mounting: Double Clevis, Bore Size: 125mm, Port Thread: NPT, Stroke: 500mm, Rod Boot: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -

Magnet: Built-in, Mounting: Double Clevis, Bore Size: 125mm, Port Thread: NPT, Stroke: 175mm, Rod Boot: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -

Magnet: Built-in, Mounting: Double Clevis, Bore Size: 125mm, Port Thread: NPT, Stroke: 350mm, Rod Boot: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -

Magnet: Built-in, Mounting: Double Clevis, Bore Size: 125mm, Port Thread: NPT, Stroke: 200mm, Rod Boot: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -

Magnet: Built-in, Mounting: Double Clevis, Bore Size: 125mm, Port Thread: NPT, Stroke: 500mm, Rod Boot: Nylon Tarpaulin, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -

Cylinder (Tube) Inner Diameter(φ): 125, Stroke(mm): 37, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Specification: -, Port thread type: NPT, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number of the switches

Cylinder (Tube) Inner Diameter(φ): 125, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Specification: -, Port thread type: NPT, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number of the switches

Cylinder (Tube) Inner Diameter(φ): 125, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Specification: -, Port thread type: NPT, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number of the switches

Cylinder (Tube) Inner Diameter(φ): 125, Stroke(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Specification: -, Port thread type: NPT, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number of the switches

Cylinder (Tube) Inner Diameter(φ): 125, Stroke(mm): 300, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Specification: -, Port thread type: NPT, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number of the switches

Cylinder (Tube) Inner Diameter(φ): 125, Stroke(mm): 350, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Specification: -, Port thread type: NPT, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number of the switches

Cylinder (Tube) Inner Diameter(φ): 125, Stroke(mm): 400, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Specification: -, Port thread type: NPT, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number of the switches

Cylinder (Tube) Inner Diameter(φ): 125, Stroke(mm): 800, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Specification: -, Port thread type: NPT, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number of the switches

Magnet: D (Built-in Magnet), Mounting: D (Double Clevis), Bore Size: 125mm, Thread: TN (NPT), Stroke: 500mm, Rod Boot: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Environmental Options: XC68 (Stainless Steel, w/Hand Chrome Plated Piston Rod)

Magnet: D (Built-in), Mounting: D (Double Clevis), Bore Size: 125mm, Port Thread: TN (NPT), Stroke: 25mm, Rod Boot: None, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: L (3m)

Magnet: D (Built-in), Mounting: D (Double Clevis), Bore Size: 125mm, Port Thread: TN (NPT), Stroke: 50mm, Rod Boot: None, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal

Magnet: D (Built-in), Mounting: D (Double Clevis), Bore Size: 125mm, Port Thread: TN (NPT), Stroke: 350mm, Rod Boot: J (Nylon Tarpaulin), Auto Switch: M9BA--Solid State, Water Resist., 2 Wire, Horizontal, Lead Wire or Prewired Connector: Z (5m)

Magnet: D (Built-in), Mounting: D (Double Clevis), Bore Size: 125mm, Port Thread: TN (NPT), Stroke: 200mm, Rod Boot: None, Auto Switch: A90--Reed, AC Volt, Horizontal, Lead Wire or Prewired Connector: L (3m), Number: S (1 pc.)