Magnet: Built-in, Mounting: Double Clevis, Bore Size: 12mm, Stroke: 150mm, Option: Rubber Bumper,Rod End Male Thread, Auto Switch: A93V--Reed, DC Volt, AC Volt, LED, Vertical, 0.5m, Lead Wire or Prewired Connector: 3m, Number: -, Thread: -
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
Magnet: D (Built-in), Mounting: B (Through Hole, Both Ends Tapped), Bore Size: 16mm, Stroke: 15mm, Option: M (Rod End Male Thread), Auto Switch: A93V--Reed, DC Volt, AC Volt, LED, Vertical, 0.5m, Lead Wire or Prewired Connector: L (3m)
Magnet: D (Built-in), Mounting: B (Through Hole, Both Ends Tapped), Bore Size: 12mm, Stroke: 15mm, Option: M (Rod End Male Thread), Auto Switch: A93V--Reed, DC Volt, AC Volt, LED, Vertical, 0.5m, Lead Wire or Prewired Connector: L (3m)
Magnet: D (Built-in), Mounting: B (Through Hole, Both Ends Tapped), Bore Size: 20mm, Stroke: 15mm, Option: M (Rod End Male Thread), Auto Switch: A93V--Reed, DC Volt, AC Volt, LED, Vertical, 0.5m, Lead Wire or Prewired Connector: L (3m)
Magnet: D (Built-in), Mounting: B (Through Hole, Both Ends Tapped), Bore Size: 16mm, Stroke: 15mm, Option: M (Rod End Male Thread), Auto Switch: A93V--Reed, DC Volt, AC Volt, LED, Vertical, 0.5M, Lead Wire or Prewired Connector: L (3m)
Magnet: Built-in, Mounting: Through Hole, Both Ends Tapped, Bore Size: 16mm, Stroke: 15mm, Option: Rod End Male Thread, Auto Switch: A93V--Reed, DC Volt, AC Volt, LED, Vertical, 0.5M, Lead Wire or Prewired Connector: 3m, Number: -, Thread: -
Magnet: Built-in, Mounting: Through Hole, Both Ends Tapped, Bore Size: 12mm, Stroke: 15mm, Option: Rod End Male Thread, Auto Switch: A93V--Reed, DC Volt, AC Volt, LED, Vertical, 0.5m, Lead Wire or Prewired Connector: 3m, Number: -, Thread: -
Magnet: Built-in, Mounting: Through Hole, Both Ends Tapped, Bore Size: 20mm, Stroke: 15mm, Option: Rod End Male Thread, Auto Switch: A93V--Reed, DC Volt, AC Volt, LED, Vertical, 0.5m, Lead Wire or Prewired Connector: 3m, Number: -, Thread: -
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: High rigidity / high precision high class guide, Environment, Applications: Standard, Cushion: None, Operating Pressure(MPa): 0.07 to 1.0, Specification: Built-in magnet, Auto Switches
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: High rigidity / high precision high class guide, Environment, Applications: Standard, Cushion: None, Operating Pressure(MPa): 0.07 to 1.0, Specification: Built-in magnet, Auto Switches
Magnet: D (Built-in Magnet), Mounting: A (Both Ends Tapped), Bore Size: 63mm, Port Thread: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 15mm, Body Option: M (Rod End Male Thread), Auto Switch Groove: None (for 12-25 Bore w/o Magnet; 32-100 Bore w/o Magnet Z must be selected), Auto Switch: A93V--Reed, DC Volt, AC Volt, LED, Vertical, Lead Wire or Prewired Connector: L (3m), Number: 2 pcs
Magnet: D (Built-in Magnet), Mounting: B (Through-hole, Standard), Bore Size: 63mm, Port Thread: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 15mm, Body Option: M (Rod End Male Thread), Auto Switch Groove: None (for 12-25 Bore w/o Magnet; 32-100 Bore w/o Magnet Z must be selected), Auto Switch: A93V--Reed, DC Volt, AC Volt, LED, Vertical, Lead Wire or Prewired Connector: L (3m), Number
Magnet: Built-in Magnet, Mounting: Both Ends Tapped, Bore Size: 63mm, Port Thread: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 15mm, Body Option: Rod End Male Thread, Auto Switch Groove: None (for 12-25 Bore w/o Magnet; 32-100 Bore w/o Magnet Z must be selected), Auto Switch: A93V--Reed, DC Volt, AC Volt, LED, Vertical, Lead Wire or Prewired Connector: 3m, Number: 2 pcs. (Or None in
Magnet: Built-in Magnet, Mounting: Through-hole, Standard, Bore Size: 63mm, Port Thread: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 15mm, Body Option: Rod End Male Thread, Auto Switch Groove: None (for 12-25 Bore w/o Magnet; 32-100 Bore w/o Magnet Z must be selected), Auto Switch: A93V--Reed, DC Volt, AC Volt, LED, Vertical, Lead Wire or Prewired Connector: 3m, Number: 2 pcs. (Or None
The CQS compact cylinder is available for those small bore cylinder applications where saving space is a concern. The CQS offers standard long strokes * in four bore sizes from 12 to 25mm. Long stroke versions incorporate a wear band and thicker piston to handle the increased bearing needs of the longer strokes. Both switch capable and non-switch capable body styles are the same, and switches
The CQS compact cylinder is available for those small bore cylinder applications where saving space is a concern. The CQS offers standard long strokes * in four bore sizes from 12 to 25mm. Long stroke versions incorporate a wear band and thicker piston to handle the increased bearing needs of the longer strokes. Both switch capable and non-switch capable body styles are the same, and switches
Magnet: D (Built-in), Mounting: D (Double Clevis), Bore Size: 12mm, Stroke: 10mm
Magnet: D (Built-in), Mounting: D (Double Clevis), Bore Size: 12mm, Stroke: 10mm, Option: C (Rubber Bumper)
Magnet: D (Built-in), Mounting: D (Double Clevis), Bore Size: 12mm, Stroke: 10mm, Option: C (Rubber Bumper), Auto Switch: No Switch, Lead Wire or Prewired Connector: M (1m)