Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:
Magnet: D (Built-in), Mounting: F (Front Flange), Type: Standard, Bore Size: 50mm, Port Thread Type: TN (NPT 32-100 Bore), Stroke: 75mm, Body Option: Standard (Rod End Female Thread), Auto Switch Groove: Z (Auto Switch Mounting Grooves), Auto Switch: M9P--Solid State , Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: MDPC (1.0m Cord Length, M12-4 Pin Connector)
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:
SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, double rod, compact cylinder, Bore sizes *: 12, 16, 20, 25,
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, CQ2-Z COMPACT CYLINDER, NX, 50MM CQ2-Z DBL-ROD AUTO-SW, 3.74785 lb
SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, double rod, compact cylinder, Bore sizes *: 12, 16, 20, 25,
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, COMPACT, DBL ROD, LONG ST, ACTUATOR, CQ2 COMPACT CYLINDER, NX, 50MM CQ2 DBL-ROD AUTO-SW, .00000 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, 50MM CQ2-Z DBL-ROD AUTO-SW, ACTUATOR, CQ2-Z COMPACT CYLINDER, NX, 50MM CQ2-Z DBL-ROD AUTO-SW, 3.77516 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, COMPACT, DBL ROD, LONG ST, ACTUATOR, CQ2 COMPACT CYLINDER, NX, 50MM CQ2 DBL-ROD AUTO-SW, .00000 lb
SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, double rod, compact cylinder, Bore sizes *: 12, 16, 20, 25
SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, compact cylinder, Bore sizes *: 12, 16, 20, 25,
SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, single rod, compact cylinder, Bore sizes *: 12, 16, 20, 25,
SMC has redesigned the CQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the CQ2s mounting rails, preventing projection of auto switches and improving ease and safety of work.Double acting, double rod, compact cylinder, Bore sizes *: 12, 16, 20, 25,
Magnet: D (Built-in), Mounting: F (Front Flange), Type: Pneumatic, Bore Size: 40mm, Stroke: 40mm, Body Option: Standard (Rod End Female Thread), Auto Switch Groove: Z (Auto Switch Mounting Grooves)
Magnet: None, Mounting: A (Both Ends Tapped), Bore Size: Ø50 mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Water Resistant Seal: V (FKM Seal, Fluororubber), Stroke: 40 mm, Body Option: Standard (Rod End Female Thread), Auto Switch Groove: Z (Auto Switch Mounting Grooves)
Bore Size: 40mm, Thread: M Thread: ø10 to ø25; Rc: ø32 to ø40, Opening/Closing Stroke: Short
Magnet: D (Built-in), Mounting: B (Through Hole [Standard]), Type: Standard, Bore Size: 40mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 40mm, Body Option: Standard (Rod End Female Thread), Auto Switch Groove: Z (Auto Switch Mounting Grooves)
Magnet: D (Built-in), Mounting: A (Both Ends Tapped), Type: Standard, Bore Size: 25mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 40mm, Body Option: Standard (Rod End Female Thread), Auto Switch Groove: Z (Auto Switch Mounting Grooves)
Magnet: D (Built-in), Mounting: A (Both Ends Tapped), Type: Standard, Bore Size: 32mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 40mm, Body Option: Standard (Rod End Female Thread), Auto Switch Groove: Z (Auto Switch Mounting Grooves)