This is a legacy product, and replaced byCQ2D50-30DCMZ, CYL, COMPACT *LQA, ACTUATOR, CQ2 COMPACT CYLINDER, ND, 50MM CQ2 DOUBLE-ACTING, 2.36754 lb, SeriesModelActionNoteCQ2StandardCQ2Double acting, Single rodExcept with rubber bumper
This is a legacy product, and replaced byCDQ2B20-30DCMZ, CYL, COMPACT *LQA, ACTUATOR, CQ2 COMPACT CYLINDER, HE, 20MM CQ2 DBL-ACT AUTO-SW, .47245 lb
This is a legacy product, and replaced byCDQ2A25-30DCMZ, CYL, COMPACT, ACTUATOR, CQ2 COMPACT CYLINDER, IE, 25MM CQ2 DBL-ACT AUTO-SW, .66138 lb
This is a legacy product, and replaced byCQ2D40-30DCMZ, CYL, COMPACT *LQA, ACTUATOR, CQ2 COMPACT CYLINDER, MD, 40MM CQ2 DOUBLE-ACTING, 1.36049 lb, SeriesModelActionNoteCQ2StandardCQ2Double acting, Single rodExcept with rubber bumper
LV at the time of Pushing force = 0, the alarm will not be activated.) (3) Minimum speed of actuator Pushing speed Speed (4) Pushing speed Maximum pushing speed of actuator (5) Pushing force Minimum pushing force of actuator (6) Basic parameters Max force Minimum pushing force of actuator (7) Basic parameters Max force Trigger LV Step data ALM1 (1-048) B RESET input
When [Pushing force] setting and [Trigger LV] are set less than [Pushing force], use the product within the specified range of [Pushing force] and [Trigger LV]. a) To ensure that the actuator pushes the workpiece with the set [Pushing force], it is recommended that the [Trigger LV] be set to the same value as the [Pushing force]. b) If the [Trigger LV] is set lower than the [operation pushing
Voltage VDW AC DC Thread type 5 6 9 24VDC 12VDC 1 2 3 4 9 100VAC 200VAC 110VAC 220VAC VC Rc G NPT NPTF Nil F N T (Other, less than 50VDC) LV (Other, less than 250VAC) PA AC specifications are only for DIN terminal and conduit terminal type. Port size Consult SMC regarding other voltages (9).
Selection of Pushing Speed P Set the [Pushing force] and the [Trigger LV] within the range shown in the figure below.
Applicable bore size LT LX LY LV Included pin part no. D C CM-E020B 20, 25 3.2 12 59 18.4 CD-S02 CM-E032B 32, 40 4 20 75 28 CD-S03 H B Part no. Applicable bore size B C D d H SN-020B 20 26 30 25.5 M20 x 1.5 8 SN-032B 25, 32 32 37 31.5 M26 x 1.5 8 SN-040B 40 41 47.3 40.5 M32 x 2.0 10 Note 1) A clevis pivot bracket pin and retaining rings are included.
D I M E N S I O N S S E R I E S (N)VHS S H U TO F F VA LV E S Y M B O L S Model Port Size Exh. Port A B C D E F Lockable Unit. Color may not be available as shown.
When operated at a very low flow rate, the series LV with flow rate adjustment may vibrate, etc. depending on the operating conditions. Therefore, operate it after careful examination of the flow rate, pressure and piping conditions. 3. In the series LV, water hammering may occur depending on the fluid pressure conditions.
When operated at a very low flow rate, the series LV with flow rate adjustment may vibrate, etc. depending on the operating conditions. Therefore, operate it after careful examination of the flow rate, pressure and piping conditions. 3. In the series LV, water hammering may occur depending on the fluid pressure conditions.
www.stevenengineering.com I 6.3 VACUUM VACUUM EJECTOR SERIES NZM H O W T O O R D E R NZM V A C U U M E J E C T O R D I M E N S I O N S W I T H VA LV E A N D VA C U U M S W I T C H W I T H V A LV E S A N D S W I T C H (N)ZM HK5LZ V O LTA G E 5 24VDC 6 12VDC N O Z Z L E D I A M E T E R 05 0.5mm 07 0.7mm 10 1.0mm 13 1.3mm V A C U U M S W I T C H Nil Without E15L Solid State (NPN) E55L Solid
(Series LV) 3. Low frequency operation In order to prevent malfunction, conduct a switching operation of a valve every 30 days.
(Series LV) 3. Low frequency operation In order to prevent malfunction, conduct a switching operation of a valve every 30 days.
Initial value: Set to [0.50] or higher. 2) Pushing operation When the effective force exceeds step data [Trigger LV], the INP output signal will turn on. Use the product within the specified range of [Pushing force] and [Trigger LV].
High Purity Chemical Valve Series LV. Series LV . Features. Series LVC Integral Fitting Type (Hyper Fittings) .
R V Integral clevis type (E)/CG5ENS ZZ + Stroke CD hole H10 Shaft d9 L M GA GB RR U CX LL 2P H1 Width across flats B1 LY CI D I MM AL A K LH LE KA 4-J LT C 0.1 NA LF LP LG S + Stroke Z + Stroke LZ + Stroke LV LX H 4-LD (mm) Stroke range A Bore size (mm) AL B1 C CD (hole) CI CX D GA GB H H1 I J K KA L M MM NA P RR S U +0.058 0 0 0.2 0 0.2 0 0.2 0 0.2 0 0.2 0 0.2 0 0.3 0 0.3 20 8 16 to 200
(Downloadable from our web site.) 491 Series LV High Purity Chemical Valve Precautions 2 Be sure to read before handling. Refer to front matters 42 and 43 for Safety Instructions. Operating Air Supply Operating Air Supply Precautions on Usage Precautions on Usage Warning Warning 1. Use clean air.
Retaining rings (cotter pins for 40) are included. 1197 Series CM2Y Clevis Pivot Bracket (For CM2E) Rod End Nut Material: Carbon steel Material: Rolled steel plate d L LV LX D C LR R +0.15 +0.05 0.040 0.076 LC hole Axis H B (mm) C D d H B Applicable bore size (mm) 20 25, 32 40 Part no.