SMC Corporation of America
Elite Part Number Search
Search Results "CDLA2D100TN-450-D-M9PV"

Features Electrical entry D-M9NV, M9PV, M9BV D-M9NWV, M9PWV, M9BWV D-M9NAVL, M9PAVL, M9BAVL D-F59, F5P, J59 D-F59W, F5PW, J59W D-F5BAL D-F5NTL, G5NTL D-A93V, A96V D-A90V D-A53, A56, B53 D-A67 Grommet (perpendicular) Diagnostic indication (2-color display) Water resistant (2-color display) Solid state Diagnostic indication (2-color display) Water resistant (2-color display) With timer Without

Auto Switch Proper Mounting Position (mm) A B C D Auto switch model D-M9 D-M9V D-M9W D-M9WV D-M9A D-M9AV D-A9 D-A9V D-M9 D-M9V D-M9W D-M9WV D-M9A D-M9AV 36.5 41.5 56.5 67 67 83.5 92.5 D-A9 D-A9V D-M9 D-M9V D-M9W D-M9WV D-M9A D-M9AV 17.5 17.5 17.5 18 18 19.5 18.5 D-A9 D-A9V D-M9 D-M9V D-M9W D-M9WV D-M9A D-M9AV 24.5 29.5 44.5 55 55 71.5 80.5 D-A9 D-A9V K dimension (Switch rail height) Bore

(mm) D-M9V D-M9WV D-M9A D-M9AV D-A9 D-A9V D-M9 D-M9V D-M9W D-M9WV D-M9A D-M9AV D-A90V D-A96V D-A93V Bore size (mm) D-A90 D-A96 D-A93 D-M9 D-M9W Bore size (mm) Mounting pattern q, w Mounting pattern e 32 32 20 22 35 20 10 15 25 12 5 10 Mounting of Auto Switch As shown below, there are 3 ways to mount the auto switch according to 3 types of electrical entries.

How to Order B 20 30 D C CQSY Without auto switch F9BW S B 20 30 D C CDQSY With auto switch Number of auto switches Built-in magnet 2 pcs. 1 pc. n pcs.

Z 11 Lead wire min. bending radius 10 Auto switch D-A7, A8 K M E S J B + Stroke A + Stroke L Rod end male thread H1 Rod end nut C1 X L1 Rod End Male Thread (mm) Bore size (mm) 63 Auto switch D-A9, F9 C1 X H1 L1 26 28.5 M18 x 1.5 33.5 80 32.5 35.5 M22 x 1.5 43.5 100 32.5 35.5 M26 x 1.5 43.5 (mm) Without auto switchWith auto switch Bore size (mm) Stroke range (mm) C D E F H I J K L M N O P

(mm) Bore size D-A9, D-A9V D-M9, D-M9V D-F9W D-F9WV (mm) 10 15 25 5 10 Minimum Stroke for Auto Switch Mounting (2 pcs.)

(mm) Bore size D-A9, D-A9V D-M9, D-M9V D-F9W D-F9WV (mm) 10 15 25 5 10 Minimum Stroke for Auto Switch Mounting (2 pcs.)

As a rule, it should be turned about 90 past the position at which tightening can be felt. 456 Cylinder with Turntable Series MGT Minimum Stroke for Mounting Operating Range (mm) (mm) Auto switch model Bore size No. of auto switches 100 80 63 Auto switch model 63 80 100 D-A9/A9V D-A9 D-A9V D-M9 D-M9V D-Z7 D-Z80 D-Y59 D-Y7P D-M9W D-M9WV D-Y69 D-Y7PV D-Y7W D-Y7WV 11 10.5 10.5 D-M9/M9V D-M9W

With head end lock D-M9 D-M9V D-M9W D-M9WV D-Z7 D-Z80 D-Y59 D-Y69 D-M9A D-M9AV D-A9 D-A9V D-Y7P D-Y7PV D-Y7W D-Y7WV D-Y7BA Auto switch Auto Switch Proper Mounting Position [mm] *1 D-M9 D-M9V D-M9W D-M9WV D-M9A D-M9AV Auto switch model D-Z7/Z80 D-Y59/Y7P D-Y69/Y7PV D-Y7W D-Y7WV D-Y7BA *1 D-A9 D-A9V *3, *4 D-P3DWA *2 D-P4DW Bore size A B A B A B A B A B 20 9 38 5 34 4 33 25 9.5 38 5.5 34 4.5

Dimensions Unit: mm D-M9 M2.5 x 4 l Auto Switch Internal Circuit D-M9N, D-M9NV Slotted set screw Indicator light DC (+) Brown 2.6 Main circuit of switch Main circuit of switch Main circuit of switch OUT Black 2.7 2.8 4 22 3.2 DC () Blue Most sensitive position 6 D-M9P, D-M9PV DC (+) Brown D-M9V M2.5 x 4 l Indicator light OUT Black Slotted set screw 3.2 8 2 4.6 DC () Blue 4 2.8 D-M9B, D-M9BV

Auto Switch Specifications Grommet PLC: Abbreviation of Programmable Logic Controller D-M9, D-M9V (With indicator light) 2-wire load current is reduced (2.5 to 40 mA) Lead-free UL certified (style2844) lead cable is used. D-M9P D-M9NV D-M9B D-M9N D-M9PV D-M9BV Auto switch part no.

D-M9WV D-M9AL D-M9AVL 16, 20 U 25 B A D-A7 D-A80 D-A7H D-A80H D-F7 D-J79 D-F7W D-J79W D-F79F D-F7NTL D-F7BAL D-A73C D-A80C D-J79C D-A79W D-F7WV D-F7V D-F7BAVL 16, 20 U A B 32 to 50 U A B 32 to 50 D-A9 D-M9 D-M9W D-M9AL D-A9V D-M9V D-M9WV D-M9AVL U B A 1384 Stopper Cylinder / Fixed Mounting Height Series RSQ Auto Switch Proper Mounting Position (Detection at Stroke End) and Its Mounting Height

D-M9P D-M9NV D-M9B D-M9N D-M9PV D-M9BV Auto switch model In-line In-line Perpendicular Perpendicular Perpendicular In-line Electrical entry direction 2-wire 3-wire Wiring type PNP NPN Output type 24 VDC relay, PLC IC circuit, Relay, PLC Applicable load 5, 12, 24 VDC (4.5 to 28 V) Power supply voltage 10 mA or less Current consumption 28 VDC or less 24 VDC (10 to 28 VDC) Load voltage 2.5

Auto Switch Proper Mounting Position (at Stroke End Detection) Center of magnet A D-M9m, D-M9mV D-M9mW, D-M9mWV (mm) D-A9, D-A9mV (mm) A Operating range Bore size 16 25 A Operating range Bore size 16 25 30 9 34 4.5 30 9 34 4.5 Note) Only adjust the setting position after confirming the auto switch is properly activated.

, D-M9NV, D-M9PV, D-F9BWV, D-F9NWV, D-F9PWV Stroke B Stroke E Model A 10 20 30 40 50 75 100 125 150 10 20 30 40 50 75 100 125 150 MXQ6 MXQ8 MXQ12 MXQ16 MXQ20 MXQ25 10 9.5 9.5 9.5 17.5 17.5 1.5 1.5 1.5 9.5 9.5 11.5 12 12 16 20 35 36 4 4 8 12 27 28 15.5 28.5 18.5 18.5 25.5 25.5 44.5 44.5 20.5 10.5 10.5 17.5 17.5 36.5 36.5 20.5 34.5 24.5 24.5 24.5 30.5 37.5 55.5 55.5 26.5 16.5 16.5 16.5

Technical Data 1219 MY1H Series Auto Switch Mounting Auto Switch Proper Mounting Position Auto Switch Proper Mounting Position (mm) D-M9 D-M9V D-M9W D-M9WV D-M9AL D-M9AV Auto switch model D-A9 D-A9V A A Bore size A A 25 32 40 81 85 112.5 116.5 133.5 137.5 Note) Adjust the auto switch after confirming the operating conditions in the actual setting.

Auto Switches: Proper Mounting Positions and Mounting Heights for Stroke End Detection D-M9 D-M9W D-M9AL D-A9 D-M9V D-M9WV D-M9AVL D-A9V CHQ CHQ CHK 32 to 100 20 CHN Approx. U CHM 25 CHS CH2 Approx. U B A CHA B A Related Products D-F7 D-F7W D-J79 D-J79W D-A7 D-A7H D-A8 D-A8H D-F7V D-F7WV D-F7BA D-F7BAV D-F7NT D-F79F D-J79C D-A73C D-A80C 32 to 100 DApprox. U B A Approx.

, D-M9NV, D-M9PV, D-M9BWV, D-M9NWV, D-M9PWV Stroke B Stroke E Model A 10 20 30 125 75 100 40 50 150 10 20 30 125 75 100 40 50 150 B MXQR6 17.5 17.5 10 9.5 9.5 9.5 1.5 1.5 1.5 9.5 9.5 MXQR8 36 35 20 28 11.5 12 12 16 4 4 8 12 27 MXQR12 44.5 44.5 25.5 36.5 25.5 36.5 15.5 28.5 18.5 18.5 20.5 10.5 10.5 17.5 17.5 MXQR16 55.5 55.5 37.5 47.5 30.5 47.5 24.5 29.5 20.5 34.5 24.5 24.5 26.5

, 500 750 15 Helical insert thread 1000 20 100, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 Non-lubricated exterior (without dust seal) 25 1500 Outside of cylinder tube with hard chrome plated 32 Non-lubricated exterior (with dust seal) 100, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 1500 40 Switch rails on both sides (with 2 pcs.)