)/A, DB, E dimensions (mm) (mm) DB E A Bore size (mm) Bore size (mm) X XA XB XC XL YY YL Z Over 25 to 175st 17.5 Over 25 to 175st 102 25st or less Over 175st 25st or less Over 175st 42 4 4.5 3 6 M8 x 1.25 16 21 97 140 20 12.5 55.5 32 32 50 4 4.5 3 6 M8 x 1.25 16 22 97 102 140 20 6 11 49 40 40 66 5 6 4 8 M10 x 1.5 20 24 50 106.5 118 161 25 9.5 21 64 50 80 5 6 4 8 M10 x 1.5 20 24 63 106.5 118
Magnet: D (Built-in), Mounting: U (Front Trunnion), Style: A (Non-lube Air Cushion), Bore Size: 50mm, Stroke: 75mm, Rod Boot: w/o Rod Boot, Lock Position: H (Rear Lock), Release of Manual: N (Non-locking Type), Auto Switch: H7B--Solid State, Gen. Purpose, 2 Wire, Lead Wire, 0.5M, Lead Wire or Prewired Connector: L (3m)
Magnet: Built-in, Mounting: Front Trunnion, Style: Non-lube Air Cushion, Bore Size: 50mm, Stroke: 75mm, Rod Boot: w/o Rod Boot, Lock Position: Rear Lock, Release of Manual: Non-locking Type, Auto Switch: H7B--Solid State, Gen. Purpose, 2 Wire, Lead Wire, 0.5M, Lead Wire or Prewired Connector: 3m, Number: -, Auto Switch Mounting Bracket: -
lo switches Bore sizel E--6,"'"-l IE ro.m I IE re '. 1 Port location on head cover stroke (l00ihs o Standard 50, 100, 150,200 50, 100, 150, 200, 300.400, 500,600 50, 100, 150. 200,300,400, 500,600,700,400 Doub e actino Sinole aclino sorinq relurn Sinale aclinq sprinq extend Se Caralog N301 ior slandard stroke Lenglhs on lypes otherrhan single rod 'lnrermedate shkes can b nanufacrured upon
' Dire.sioB olfFr ll'a. lle abole a t1e same ds hN u the basic tps (ar th6 bn).
' Dire.sioB olfFr ll'a. lle abole a t1e same ds hN u the basic tps (ar th6 bn).
40-140'F(5-m'c 2 -20 inch/sec {50 -500 mm/sec) 2 -30 jnch/sec (50-750 mm/sec) Not required (prelubricated at factory) Standard Stroke LLst Owhen mounting, completelyflush the piping and be careful that dust and chips do not erterthe cylinder. )Load of piston rod should always be aligned parallel with the cylinder axis.
40-140'F(5-m'c 2 -20 inch/sec {50 -500 mm/sec) 2 -30 jnch/sec (50-750 mm/sec) Not required (prelubricated at factory) Standard Stroke LLst Owhen mounting, completelyflush the piping and be careful that dust and chips do not erterthe cylinder. )Load of piston rod should always be aligned parallel with the cylinder axis.
Max.120'F(50'C) 2position : 20 ms or less 3position : 50 ms or less (70 PSI) Operating pressute range Ambient and fluid temPerature Flesponse time Max.
Max.120'F(50'C) 2position : 20 ms or less 3position : 50 ms or less (70 PSI) Operating pressute range Ambient and fluid temPerature Flesponse time Max.
Magnet: D (Built-in), Mounting: U (Front Trunnion), Style: A (Non-lube Air Cushion), Bore Size: 50mm, Stroke: 75mm, Rod Boot: w/o Rod Boot, Lock Position: H (Rear Lock), Release of Manual: L (Locking)
Magnet: D (Built-in), Mounting: U (Front Trunnion), Style: A (Non-lube Air Cushion), Bore Size: 50mm, Stroke: 250mm, Rod Boot: w/o Rod Boot, Lock Position: H (Rear Lock), Release of Manual: L (Locking)
Magnet: D (Built-in), Mounting: U (Front Trunnion), Style: A (Non-lube Air Cushion), Bore Size: 50mm, Stroke: 100mm, Rod Boot: w/o Rod Boot, Lock Position: H (Rear Lock), Release of Manual: L (Locking)
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Non-use of Copper and fluoropolymer-based Material (Partially Plating), End Locking: [Included] Presence, Valves: -, Cushion: Air cushion, Operating Pressure(
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Non-use of Copper and fluoropolymer-based Material (Partially Plating), End Locking: [Included] Presence, Valves: -, Cushion: Air cushion, Operating Pressure
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Non-use of Copper and fluoropolymer-based Material (Partially Plating), End Locking: [Included] Presence, Valves: -, Cushion: Air cushion, Operating Pressure(
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 250, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Non-use of Copper and fluoropolymer-based Material (Partially Plating), End Locking: [Included] Presence, Valves: -, Cushion: Air cushion, Operating Pressure
Magnet: Built-in, Mounting: Front Trunnion, Style: Non-lube Air Cushion, Bore Size: 50mm, Stroke: 100mm, Rod Boot: w/o Rod Boot, Lock Position: Rear Lock, Release of Manual: Locking, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, Auto Switch Mounting Bracket: -
Magnet: D (Built-in), Mounting: F (Front Flange), Bore Size: 100mm, Port Thread: Rc, Stroke: 500mm, Rod Boot: None, Lock Style: HN (With Rear End Lock Non-locking Style)
Magnet: D (Built-in), Mounting: B (Basic Style), Bore Size: 40mm, Port Thread: Rc, Stroke: 125mm, Rod Boot: None, Lock Style: HN (With Rear End Lock Non-locking Style), Auto Switch: M9BA--Solid State, Water Resist., 2 Wire, Horizontal, Lead Wire or Prewired Connector: L (3m)