SMC Corporation of America
Elite Part Number Search
Search Results "CDBG1FA80-1200-HL-B64"

Minimum operating voltage of load Supply voltage > Internal voltage drop of switch 2) If the internal resistance of a light emitting diode causes a problem, select a switch without an indicator light (D-A6, DA80, D-A80H, D-A90, D-A90V, D-B64, D-C80, or D-Z80).

D-G5, K59, G5W, K59W, G5BA, G59F, G5NT, B5, B64, and B59W Note 2) Adjust the auto switch after confirming the operating conditions in the actual setting.

Mounting of Auto Switch D-B5, B64, G5, D-K5 types are mountable only upon a receipt of order. (Not mountable after the time of shipment) Mounting Bracket Part No.

Bore size (mm) Standard stroke (mm) Range of manufacturable stroke* Without rod boot With rod boot Without rod boot With rod boot 40 25 to 850 25 to 700 Up to 1200 Up to 950 50 25 to 800 25 to 650 Up to 1150 Up to 900 63 25 to 800 25 to 650 Up to 1150 Up to 900 80 25 to 750 25 to 600 Up to 1100 Up to 900 100 25 to 750 25 to 600 Up to 1100 Up to 850 Refer to pages 692 to 697 for cylinders

100 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1300 Intermediate strokes and short strokes other than the above are produced upon receipt of order.

Types D-B53, D-B54, D-B64 and D-B59W cannot be mounted on bore size 63 cylinders. Lead wire length symbols: 0.5m . Nil (Example) A53 3m . L (Example) A53L 5m . Z (Example) A53Z 103 Tie-rod Type Low Pressure Hydraulic Cylinder Double Acting/Double Rod Series CHAW Models Light Principle parts are light weight aluminum alloy.

Standard Stroke Bore size (mm) Standard stroke (mm) Range of manufacturable stroke Auto switch model 40 CV Bore size (mm) 50 63 80 100 Without rod boot With rod boot Without rod boot With rod boot D-A5/A6 D-A59W D-F5/J5 D-F5W/J59W D-F5NTL D-F5BAL/F59F D-A3/A44 D-G39/K39 D-B5/B64 D-B59W D-G5/K59 D-G5W/K59W D-G5BAL D-G59F/G5NTL 40 25 to 850 25 to 700 Up to 1200 Up to 950 MVGQ 50 25 to 800 25

Standard Stroke Bore size (mm) Standard stroke (mm) Range of manufacturable stroke Auto switch model 40 CV Bore size (mm) 50 63 80 100 Without rod boot With rod boot Without rod boot With rod boot D-A5/A6 D-A59W D-F5/J5 D-F5W/J59W D-F5NTL D-F5BAL/F59F D-A3/A44 D-G39/K39 D-B5/B64 D-B59W D-G5/K59 D-G5W/K59W D-G5BAL D-G59F/G5NTL 40 25 to 850 25 to 700 Up to 1200 Up to 950 MVGQ 50 25 to 800 25

179 (191) +l Up to 600 Up to 1200 C95 202 (216) +l Up to 750 Up to 1400 202 (219) +l Up to 750 Up to 1500 CA1 Note 1) ( ): Long stroke Note 2) End boss is machined on the flange for E.

I J to 350 20 18 15.5 13 14 8 12.5 12 2 12 12 35 5 25.3 37 26 M4 x 0.7 depth 7 to 400 25 22 19.5 17 16.5 10 12.5 14 2 12 12 40 6 28.3 40 31 M5 x 0.8 depth 7.5 to 450 32 22 19.5 17 20 12 12 18 2 12 12 40 6 31.3 43 38 M5 x 0.8 depth 8 to 800 40 30 27 19 26 16 15 25 2 13 13 50 8 38.3 52.5 47 M6 x 1 depth 12 to 1200 50 35 32 27 32 20 16.5 30 2 14 14 58 11 44.5 58.5 58 M8 x 1.25 depth 16 to 1200

400 600 800 1000 1200 1400 1600 Stroke [mm] Stroke [mm] (1 Kg = 2.2 lbs) [Graph 7] Allowable load mass by stroke 40 100 y, z + A = 0 y, z + A = 50 Load mass [kg] y, z + A = 100 y, z + A = 200 10 y, z + A = 300 1 0 200 400 600 800 1000 1200 1400 1600 If load center of gravity exceeds the value of y, z + A on the graph, please consult SMC.

B L 16 MY3 XB22 200 Shock absorber soft type Series RJ type Model Bore size Stroke adjustment unit 40 RJ1412H 50 32 RJ1412H 25 RJ1007H RJ1412H 20 RJ1007H RJ1412H RJ1007H RJ1412H 16 RJ0806H RJ1007H RJ0806H RJ1007H RJ0806H RJ1007H L, LS, SL H, HS, SH, LH, HL L, LS, SL H, HS, SH, LH, HL MY3B RJ1412H MY3M Ordering Example Stroke adjustment unit symbol How to order single pieces of stroke adjustment

Also, for long stroke operation involving vibration and impact, use of a side support is recommended even if the spacing value is within the allowable limits shown in the graph. 90 MY1C63 MY1C63 MY1C63 MY1C63 80 (1600) (1600) (1600) (1600) 70 MY1C50 MY1C50 MY1C50 MY1C50 l l 60 (1400) (1400) (1400) (1400) MY1C40 MY1C40 MY1C40 MY1C40 50 MY1C32 MY1C32 MY1C32 MY1C32 40 (1200) (1200) (1200) (1200

B Counter bore depth C Thread depth M T 4 x LD PA K 4 x MM F XLm XLmQ QW XMm XYm PB D-m N XVD A E depth EK XGT G Q + Stroke Z + Stroke Stroke adjustment screw (inner cover) CYV LW A A HP H HL HA HA HI TA TA R 4 x J 2 x P 2 x Counterbore dia.

LF Body Switch rail FG X A FH XA HL HB Note 1) Note 1) FF D' Floating block FE Note 1) Section D-D' 20, 25, 32, 40 D Attached from top with CAP bolt Floating block L LA A LF Attached from bottom with CAP bolt Bolt size: MD XB WF FG XA 2-SS (Helical insert thread) Body R S HL Note 1) Note 2) HB FF Note 1) Switch rail FC D' Section D-D' (mm) A BA BB CC FC FE (1) FG FH HB (1) HL L LA LF MD

Note1) D1: max. diameter SKQ5, #15 to #26 Kl Ml Hl Dl MS Tl 2.1-16 Series KQ2 Universal female elbow: KQ2VF Thread Rc(PT) R(PT) Tube O.D. (mm) H (Hex.)

250 63 1500 up to 1200 250 80 1500 up to 1400 250 100 1500 up to 1500 250 Note 1) Strokes shorter than the recommended minimum stroke (1 to 249 st) can be manufactured, but cushion capability may not be satisfied since the effective cushion stroke for this cylinder is long.

I , ~ R. t:l' t y X BN N X Y 1 S + Stroke H LS + Stroke ZZ + Stroke Long Stroke Bore size Stroke ) (mm) range (mm) RT RV 40 501-800 50 601 1000 1001 1200 30 76 , 63 601-1000 1001-1200 40 92 80 751-1000 1001 1400 45 112 100 7511000 . . .

) (1200) (1200) (1200) (1200) (1200) MY1MW25 MY1MW25 MY1CW25 MY1CW25 (1000) (1000) (1000) (1000) MY1MW20 MY1MW20 30 30 (1000) (900) (1000) (900) (1000) (900) (1000) (900) Caution MY1CW20 MY1CW20 MY1CW16 MY1MW16 MY1MW16 MY1CW16 MY1CW16 (900) (900) (900) (900) 20 20 1.

Support brackets are not for mounting; use them solely for providing support. m 90 MY1C63 MY1C63 MY1C63 MY1C63 80 (1600) (1600) (1600) (1600) (1600) (1600) 70 MY1C50 MY1C50 MY1C50 MY1C50 MY1C50 MY1C50 l l 60 (1400) (1400) (1400) (1400) (1400) (1400) MY1C40 MY1C40 MY1C40 MY1C40 50 MY1C32 MY1C32 MY1C32 MY1C32 MY1C32 MY1C32 40 (1200) (1200) (1200) (1200) (1200) (1200) MY1C25 MY1C25 MY1C25 MY1C25