(mm) How to view the diagram (ex: when using a 100 to 450st cylinder): Draw a line perpendicularly from the cylinder stroke of 450 to the point at which it intersects the (curve) cylinder bore size of 100, and extend it to the left to obtain the displacement of approximately 5,300cm3. Then, select a converter with a larger capacity. The converter will be 160 to 300.
Min. cycle time 4.2 ms Process data length Input Data: 8 byte, Output Data: 0 byte On request data communication Available Data storage function Available Event function Available Vendor ID 131 (0x0083) ISA3-FL-: 341 (0x0155) ISA3-GL-: 342 (0x0156) ISA3-HL-: 343 (0x0157) Device ID 1: Refer to the relationship between the display value and distance on page 20 for details. 2: For ISA3-F type
Magnet: D (Built-in), Mounting: F (Front Flange), Style: A (Non-lube Air Cushion), Bore Size: 32mm, Stroke: 250mm, Rod Boot: w/o Rod Boot, Lock Position: H (Rear Lock), Release of Manual: L (Locking)
Magnet: D (Built-in), Mounting: F (Front Flange), Style: A (Non-lube Air Cushion), Bore Size: 32mm, Stroke: 75mm, Rod Boot: w/o Rod Boot, Lock Position: H (Rear Lock), Release of Manual: L (Locking)
Magnet: D (Built-in), Mounting: F (Front Flange), Style: A (Non-lube Air Cushion), Bore Size: 32mm, Stroke: 50mm, Rod Boot: w/o Rod Boot, Lock Position: H (Rear Lock), Release of Manual: L (Locking)
Magnet: D (Built-in), Mounting: F (Front Flange), Style: A (Non-lube Air Cushion), Bore Size: 32mm, Stroke: 150mm, Rod Boot: w/o Rod Boot, Lock Position: H (Rear Lock), Release of Manual: L (Locking)
Magnet: D (Built-in), Mounting: F (Front Flange), Style: A (Non-lube Air Cushion), Bore Size: 32mm, Stroke: 1200mm, Rod Boot: w/o Rod Boot, Lock Position: H (Rear Lock), Release of Manual: L (Locking)
Magnet: D (Built-in), Mounting: F (Front Flange), Style: A (Non-lube Air Cushion), Bore Size: 32mm, Stroke: 200mm, Rod Boot: w/o Rod Boot, Lock Position: H (Rear Lock), Release of Manual: L (Locking)
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Non-use of Copper and fluoropolymer-based Material (Partially Plating), End Locking: [Included] Presence, Valves: -, Cushion: Air cushion, Operating Pressure(
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 1200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Non-use of Copper and fluoropolymer-based Material (Partially Plating), End Locking: [Included] Presence, Valves: -, Cushion: Air cushion, Operating Pressure
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Non-use of Copper and fluoropolymer-based Material (Partially Plating), End Locking: [Included] Presence, Valves: -, Cushion: Air cushion, Operating Pressure
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 370, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Non-use of Copper and fluoropolymer-based Material (Partially Plating), End Locking: [Included] Presence, Valves: -, Cushion: Air cushion, Operating Pressure(
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Non-use of Copper and fluoropolymer-based Material (Partially Plating), End Locking: [Included] Presence, Valves: -, Cushion: Air cushion, Operating Pressure(
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 1200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Non-use of Copper and fluoropolymer-based Material (Partially Plating), End Locking: [Included] Presence, Valves: -, Cushion: Air cushion, Operating Pressure
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Non-use of Copper and fluoropolymer-based Material (Partially Plating), End Locking: [Included] Presence, Valves: -, Cushion: Air cushion, Operating Pressure
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 370, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Non-use of Copper and fluoropolymer-based Material (Partially Plating), End Locking: [Included] Presence, Valves: -, Cushion: Air cushion, Operating Pressure(
Magnet: Built-in, Mounting: Front Flange, Style: Non-lube Air Cushion, Bore Size: 32mm, Stroke: 250mm, Rod Boot: w/o Rod Boot, Lock Position: Rear Lock, Release of Manual: Locking, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, Auto Switch Mounting Bracket: -
Magnet: Built-in, Mounting: Front Flange, Style: Non-lube Air Cushion, Bore Size: 32mm, Stroke: 50mm, Rod Boot: w/o Rod Boot, Lock Position: Rear Lock, Release of Manual: Locking, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, Auto Switch Mounting Bracket: -
Magnet: Built-in, Mounting: Front Flange, Style: Non-lube Air Cushion, Bore Size: 32mm, Stroke: 150mm, Rod Boot: w/o Rod Boot, Lock Position: Rear Lock, Release of Manual: Locking, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, Auto Switch Mounting Bracket: -
Magnet: D (Built-in), Mounting: F (Front Flange), Style: A (Non-lube Air Cushion), Bore Size: 32mm, Stroke: 100mm, Rod Boot: w/o Rod Boot, Lock Position: H (Rear Lock), Release of Manual: L (Locking), Auto Switch: H7B--Solid State, Gen. Purpose, 2 Wire, Lead Wire, 0.5M, Lead Wire or Prewired Connector: L (3m)