Body Size: 3000, Thread: Rc, Port Size: 3/8, Option: w/Bracket, Voltage: 24 VDC, Lead Wire: Type Y, DIN Terminal w/Connector, Surge Suppressor: None, Manual Override: Push-turn Locking Lever Type, Flow Direction/Pressure Unit: Flow Direction: Right to Left
Body Size: 3000, Thread: Rc, Port Size: 3/8, Option: w/Bracket, Voltage: 24 VDC, Lead Wire: Type Y DIN Terminal w/o Connector, Surge Suppressor: None, Manual Override: Push-turn Locking Lever Type, Flow Direction/Pressure Unit: Flow Direction: Right to Left
Regulator Unit Combination: [Other FRL Combination Devices] Soft Start Up Valve, Port Size: Rc3/8, Filter Rating: 5μm, Compressed Air Quality: General Dry Air, Maximum Operating Pressure(MPa): 1, Case Material: [Resin] Polycarbonate Case, Case Guard: Presence, Exhaust Structure: Relief type, Flow Direction: [Standard Flow (Left to Right)] Left to right, Drain Cock: [Not Provided] No, Pressure
Regulator Unit Combination: [Other FRL Combination Devices] Soft Start Up Valve, Port Size: Rc3/8, Filter Rating: 5μm, Compressed Air Quality: General Dry Air, Maximum Operating Pressure(MPa): 1, Case Material: [Resin] Polycarbonate Case, Case Guard: Presence, Exhaust Structure: Relief type, Flow Direction: [Reverse Flow (Right to Left)] Right to left, Drain Cock: [Not Provided] No, Pressure
Regulator Unit Combination: [Other FRL Combination Devices] Soft Start Up Valve, Port Size: NPT3/8, Filter Rating: 5μm, Compressed Air Quality: General Dry Air, Maximum Operating Pressure(MPa): 1, Case Material: [Resin] Polycarbonate Case, Case Guard: Presence, Exhaust Structure: Relief type, Flow Direction: [Standard Flow (Left to Right)] Left to right, Drain Cock: [Not Provided] No, Pressure
Size: 3/8, Thread: Rc, Port Size: 3/8-AV3000 only, Option: Pressure Gauge, Voltage: 24VDC, Lead Wire: DIN Terminal, Surge Suppressor: Light+Surge Suppressor, Manual Override: Locking (Lever Type), Flow Direction: Right to Left, Q: -
Size: 3/8, Thread: NPT, Port Size: 3/8-AV3000 only, Option: None, Voltage: 24VDC, Lead Wire: DIN Terminal, Surge Suppressor: Light+Surge Suppressor, Manual Override: Locking (Lever Type), Flow Direction: Right to Left, Q: -
Series AV is a soft start up valve for low-speed air supply to gradually raise initial pressure in an air system and for quick exhaust by cutting off air supply.
Series AV is a soft start up valve for low-speed air supply to gradually raise initial pressure in an air system and for quick exhaust by cutting off air supply.
Regulator Unit Combination: [Other FRL Combination Devices] Soft Start Up Valve, Port Size: NPT3/8, Filter Rating: 5μm, Compressed Air Quality: General Dry Air, Maximum Operating Pressure(MPa): 1, Case Material: [Resin] Polycarbonate Case, Case Guard: Presence, Exhaust Structure: Relief type, Flow Direction: [Reverse Flow (Right to Left)] Right to left, Drain Cock: [Not Provided] No, Pressure
Size: 3/8, Thread: Rc, Port Size: 3/8-AV3000 only, Option: None, Voltage: 24VDC, Lead Wire: DIN Terminal, Surge Suppressor: Light+Surge Suppressor, Manual Override: Locking (Lever Type), Flow Direction: Right to Left, Q: CE Marked
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
Part Number Description: VALVE SPRING (AV3000) Product Line: V Product Line Description: VALVE Click here to report information errorImage shown may not match exact part number, VALVE SPRING (AV3000), VALVE, AV SOFT START UP BODY PORT, 21, AV NO SIZE RATING, 0.044 lb
Series AV is a soft start up valve for low-speed air supply to gradually raise initial pressure in an air system and for quick exhaust by cutting off air supply.
This is a legacy product, and replaced byAL40-03B-A
This is a legacy product, and replaced byVP542-5G1-03B
This is a legacy product, and replaced byVHS30-03B-K
This is a legacy product, and replaced byAR25-03B-B
This is a legacy product, and replaced byVP742R-1D1-03B