3, Steel ball AXT625-3A-10 Non plug-in type (For 10) (3) Note 1) For side ported Note 2) 1: A, B port size Rc 1/8, 2: A, B port size Rc 1/4 Note 3) Please contact SMC if parts except for 10/01T/01T1 are needed.
A, B P, R1, R2 Rc 1/2 Rc 3/4 Mixed 10 10 stations Rc 3/4 Note 1) Max. 10 stations.
Symbol 02 2 stations A, B P , EA, EB Symbol 04 06 Passage Porting specifications (A, B) EA, EB P 10 10 stations 1 2 Symbol 3 4 3 4 1 Side 2 Bottom M Mixed Common Common For bottom ported: 1/2 only.
Symbol 02 03 A, B P D Nil D side mounting None 01T, 10 1 4 Rc Rc Rc M Mixed 3 8 1 2 U 01C, 01F U side mounting Stations Symbol Porting specifications (A, B) 02 Passage 2 stations Symbol R1, R2 P 10 10 stations 1 Side 2 Bottom Common Common Base type 01T, 10: 2-10 stations Base type 01C, 01F: 2-8 stations Option Please indicate manifold base type, corresponding valve, and option parts.
Note 3) The value at a temperature of 20C, with a 10% or less O.D. variable rate.
Min. Dripping Flow Rate(l/min): 220, Oil Storage Capacity(cm3): 135, Case: [Resin] Polycarbonate Case, Inlet Side Connection Type: Rc, Inlet Side Plumbing Thread Nominal: 1, Outlet Side Connection Type: Rc, Outlet Side Plumbing Thread Nominal: 1, Drain Exhaust: [Not Provided] No Drain Cock, Flow Direction: [Right] From Left to Right, Size of Body: 60, Accessory: Without optional
Body Size: 60, Thread: Rc (Rc: for Sizes 20~60; M5: for Size 10), Port Size: 10 (1), Mounting: None, Semi-Standard, Body Size 10: Standard, Semi-Standard, Body Size 20: Standard, Semi-Standard, Body Size 30, 40, 50 & 60: Standard
(mm) 10 8 12 4 6 I.D. (mm) 5 6.5 4 8 2.5 Bend the tube into U-form at a temperature of 20C. Fix one end and close loop gradually. Measure 2R when the tube breaks or is crushed.
A vacuum pad is a consumable part, so it is warranted for a year after it is delivered. Also, even within the warranty period, the wear of a product due to the use of the vacuum pad or failure due to the deterioration of rubber material are not covered by the limited warranty.
8 6 4 12 O.D. mm 6.5 5 4 2.5 8 I.D. mm Black (B) White (W) Blue (BU) Translucent (N) Specifications Air Note 1) Fluid Max. operating pressure (at 20C) (68F) 1.0MPa (145 psi) Note 2) Min. bending radius mm 10 15 20 27 35 2R At a temperature of 20C (68F) bend the tubing into a U shape.
8 6 4 12 O.D. mm 6.5 5 4 2.5 8 I.D. mm Black (B) White (W) Blue (BU) Translucent (N) Specifications Air Note 1) Fluid Max. operating pressure (at 20C) (68F) 1.0MPa (145 psi) Note 2) Min. bending radius mm 10 15 20 27 35 2R At a temperature of 20C (68F) bend the tubing into a U shape.
Min. bending radius (mm) Note 3) 25 20 10 35 25 55 35 85 60 95 220 At a temperature of 20C, bend the tubing into a U shape. Fix one end and gradually move the other end closer. Measure 2R at the point where the outside diameter's rate of change is 5%.
Contact P/A if an application under such conditions cannot be avoided. 10 One-touch fitting 10 One-touch fitting Parts list Material AFM20 Zinc die-cast AFM30, AFM40, AFM40-06 Aluminum die-cast Note Description No. Body 1 Platinum silver Replacement parts Part no. No.
Size: 1, Thread: G, Port Size: 1, Accessory: None, Option 1: Metal Bowl, Option 2: Flow Direction: Right->Left
Note 5) As for other commercial items, there are some cases it is not able to connect due to tolerance of dimensions. 2R Fixed side At a temperature of 20C, bend the tubing into a U shape. Fix one end and gradually move the other end closer. Measure 2R at the point where the outside diameters rate of change is 5%.
Please note that the refraction value is not warranted because of the value when 2R is measured by the method in the left figure if the tubing is bent or flattened, etc. At a temperature of 20C, bend the tubing into a U shape. Fix one end and gradually move the other end closer. Measure 2R at the point where the outside diameter's rate of change is 10%.
Printing/Fluid Print code Fluid SMC TS 0604 SOFTNYLON 6 x 4 SMC TS 0604 SOFTNYLON 6 x 4 Previous Air NEW Air/Water How to Order Length per roll Color How to measure the minimum bending radius 20 TS0604 W 2R Symbol Length Symbol Color At a temperature of 20C, bend the tubing into a U shape. Fix one end and gradually move the other end closer.
QCR: When the internal volume of a rotary actuator varies depending on the A and B ports, use formula (1). P + 0.1 0.1 QCR = V x x 10-. Formula (1) P + 0.1 0.1 Formula QC2 = QC x n x Number of actuators x Reserve factor . Formula (5) QCR = 2V x x 10-. Formula (2) P 0.1 QCP = 2 x a x L x x 10-.
Class Size combination Applicable tubing size (mm) 4 x 3 3 x 2 6 x 4 4 x 3 6 x 4 4 x 3 10 x 8 8 x 6 6 x 4 10 x 8 8 x 6 6 x 4 12 x 10 10 x 8 12 x 10 10 x 8 19 x 16 12 x 10 19 x 16 12 x 10 25 x 22 19 x 16 25 x 22 19 x 16 Connection threads Symbol 1 2 2 2 2 2 2 3 3 3 3 4 4 4 4 5 5 5 5 6 6 6 6 Connection threads A A B C D E F A B C D A B C D A B C D A B C D Applicable tubing size (inch) No.
I = I + IA kgm (m to m : Mass of I to I kg) D Calculation example When d1 = 0.1m, d = 0.05m, D = 0.04m, a = 0.04m, b = 0.02m m = 1kg, m = 0.4kg, m = 0.5kg, m = 0.2kg, Gear tooth ratio = 2 Cylinder: I I = 0.2 x = 0.03 x 10 -3kg m I = 1 x = 1.25 x 10 -3 kgm 0.1 8 0.04+0.02 12 b IB = (0.13 + 0.1 + 0.03) x 10 -3= 0.26 x 10 -3 kgm 0.05 8 I = 0.4 x = 0.13 x 10 -3 kgm a IA = 2 x 0.26 x 10 -3 = 1.04