O.D.: 6 1/4" One-touch fitting [1(P), 3/5(E) port] Applicable tubing O.D.: 12 3/8" One-touch fitting [4(A), 2(B) port] Applicable tubing O.D.: 6, 1/4" 8, 5/16" 10, 3/8" U side D side L3 (L4) L5 6.5 31.6 DIN rail holding screw (For DIN rail mounting) (5.3) (5.1) SI unit 68.5 10.1 9.5 B B B B B 8 128.8 115.8 A A A A A 83.8 5 35 COM PWR 5.5 A B A B 14.3 29.6 46.9 Manual override Press and turn
One-touch fitting [X: External pilot port] Applicable tubing O.D.: 6 N7 One-touch fitting [PE: Pilot EXH port] Applicable tubing O.D.: 6 N7 Rc 1/4, 3/8 [4(A), 2(B) port] L3 (L4) U side D side L5 47.3 4-6.2 (for mounting) (5.4) [for Rc 1/4, 3/8] DIN rail holding screw (for DIN rail mounting) 13.3 81.7 75 B B B B B 8 164.7 148.2 5.5 35 A A A A A 98.2 A B A B 1 2 3 4 5 6 7 8 9 10 11 12 13 14
option L1 4 A 4 A 4 A 4 A 41 42 E 3/5 E 3/5 64.2 2 B 2 B 2 B 2 B (Station n) (Station 1) 77.5 1 P 1 P 78 E 3 P 1 Light/Surge voltage suppressor (6) Individual EXH spacer Individual SUP spacer MAX.14 109.5 SV100-06Interface regulator SV100-05Interface regulator (DIN rail dimension) 61.2 (47.3) 7.5 48 19.7 Block separation lever B B B B 102.9 111.4 118 100.4 91.9 A A A A B A B A B A B A Dimensions
A-40 . 9-1 9.1.2 HRL100/200-W-40 . 9-3 9.1.3 Refrigerant with GWP reference. 9-5 9.1.4 Communication specifications . 9-5 9.2 Dimensions . 9-6 9.2.1 HRL100-A-40 . 9-6 9.2.2 HRL200-A-40 . 9-7 9.2.3 HRL300-A-40 . 9-8 9.2.4 HRL100/200-W-40 . 9-9 9.3 Flow Diagram . 9-10 9.3.1 HRL-A-40. 9-10 9.3.1 HRL-W-40. 9-11 9.4 Cooling Capacity . 9-12 9.4.1 HRL100A40 CH1 . 9-12 9.4.2 HRL200A40 CH1 . 9-12
20 . 8-1 8.1.2 Refrigerant with GWP reference. 8-2 8.1.3 Communication specifications . 8-2 8.2 Dimensions . 8-3 8.2.1 HRL100-A-20 . 8-3 8.2.2 HRL200-A-20 . 8-4 8.2.3 HRL300-A-20 . 8-5 8.3 Flow Diagram . 8-6 8.3.1 HRL-A-20 . 8-6 8.4 Cooling Capacity . 8-7 8.4.1 HRL100-A-20 CH1 . 8-7 8.4.2 HRL200-A-20 CH1 . 8-7 8.4.3 HRL300-A-20 CH1 . 8-8 8.4.4 HRL100/200/300-A-20 CH2 . 8-8 8.5 Pump Capacity
20 . 8-1 8.1.2 Refrigerant with GWP reference. 8-2 8.1.3 Communication specifications . 8-2 8.2 Dimensions . 8-3 8.2.1 HRL100-A-20 . 8-3 8.2.2 HRL200-A-20 . 8-4 8.2.3 HRL300-A-20 . 8-5 8.3 Flow Diagram . 8-6 8.3.1 HRL-A-20 . 8-6 8.4 Cooling Capacity . 8-7 8.4.1 HRL100A20 CH1 . 8-7 8.4.2 HRL200A20 CH1 . 8-7 8.4.3 HRL300A20 CH1 . 8-8 8.4.4 HRL100/200/300-A-20 CH2 . 8-8 8.5 Pump Capacity . 8
Set contact output signal 4 to 6. Contact output signal is continuously output. A Signal type for contact output signal 4 to 6 can be selected by the customer. Refer to Table 5.4-24 Signal type for contact output signals 4 to 6. Select the Contact type and Signal type for contact output signals 4 to 6. Contact output signal 4selects Signal type and N.O. (A contact ) or N.C.
27.5 B 17 19 18 23.5 A 13.5 11.5 18.5 23 B 12.5 14.5 13.5 19 B 9 11 10 15.5 B 7 9 8 13.5 B 13 15 14 19.5 A 14.5 12.5 19.5 24 B 13.5 15.5 14.5 20 B 7.5 9.5 8.5 14 B 10.5 12.5 11.5 17 B 7 9 8 13.5 A 8 6 13 17.5 A 14 12 19 23.5 A 8.5 6.5 13.5 18 A 11.5 9.5 16 21 A 8 6 13 17.5 20 25 32 40 Note) When setting an auto switch, be sure to check its operation before adjusting.
Note 3) When tightening an auto switch mounting screw (M2.5), use a watchmakers screwdriver with a grip diameter of 5 to 6 mm. Also, set the tightening torque to be 0.05 to 0.15 Nm. As a guide, turn 90 from the position where it comes to feel tight.
(JSXFA) Blow tube Nozzle 2-port solenoid valve Number of output points Voltage D 24 to 48 VDC D-6 12 VDC A1 85 to 240 VAC Clean air outlet 06 6 output points 10 10 output points IN Bag filter IN 1 A is not a CE marked product.
6 Cylinder bore size 20 5 5 4 (Steel pipe I.D.) 4 3 2 7 6 5 4 3 2 20 30 40 50 60 80 100 200 300 400 500 2.8 Flow velocity inside pipe (m/s) Piston speed (mm/s) Viewing the chart: Example) The flow rate necessary to operate a 50 cylinder at a speed of 100mm/s is 12l/min.
Standard Specifications AC20-A AC25-A AC30-A AC40-A AC40-06-A Model AF40-06-A AR40-06-A AL40-06-A AF40-A AR40-A AL40-A AF30-A AR30-A AL30-A AF30-A AR25-A AL30-A AF20-A AR20-A AL20-A Air filter Regulator Lubricator Component Port size Pressure gauge port size Fluid 3/4 1/8, 1/4 1/4, 3/8 1/8 1/4, 3/8 1/4, 3/8, 1/2 Air 5 to 60C (with no freezing) 1.5 MPa 1.0 MPa 0.05 to 0.7 MPa 5 m Class 1
Model A B C D Y Y A B C D Flat Model ZPT10D-6-A10 10 12 15 24 6 Flat with ribs U C ZPT13 -6-A10 U C ZPT16 -6-A10 U C ZPT16D-6-A10 ZPT10 -6-A10 16 18 16 25 7 10 12 15 12 21 1.7 1.8 3 13 Dimensions by Stroke 16 18 12.5 21.5 1.2 3.5 10 16 G Model Dimensions by Stroke E F E F 10, 13 16 ZPTD10-6-A10 35.5 73.5 23 36.5 74.5 G Model E F E F ZPTD20-6-A10 45.5 111.5 46.5 112.5 51 U C ZPT 20-6-A10 U
) 2 position/Double : VQ7-6-FG-D-SC Double (reverse pressure): VQ7-6-YZ-D-SC 3 position/Closed center : VQ7-6-FHG-D-SC Exhaust center : VQ7-6-FJG-D-SC Pressure center : VQ7-6-FIG-D-SC 145 86.5 155 68.5 76.5 50 50 68.5 50 50 Manual override 13 (port A) 13 (port B) Manual override 13 (port A) 13 (port B) B A B A 62 38 50 38 50 62 A B A B Prewired connector (M12) (L approx. 500) R1 R2 P Prewired
Note 6) The built-in silencer type does not satisfy the IP67 standard. Note 7) The supply and exhaust ports on U side are branched (to the cylinder port side and coil side). A One-touch fitting for 12 is attached to each port.
1 NOT USED NOT USED PIN 2 PIN 2 PIN 2 PIN 2 12 (B) + 12 (B) + PIN 2 PIN 2 14 (A) + 14 (A) + PIN 3 PIN 3 COMMON COMMON COMMON COMMON PIN 3 PIN 3 PIN 3 PIN 3 COMMON COMMON PIN 4 PIN 4 12 (B) + 12 (B) + PIN 4 PIN 4 14 (A) + 14 (A) + 12 (B) + 12 (B) + PIN 4 PIN 4 TERMINAL STRIP 22 POSITION TERMINAL STRIP 22 POSITION TERM P7=OUT 6 TERM P7=OUT 6 TERM P1=OUT 0 TERM P1=OUT 0 TERM P13=OUT 12 TERM
Indication Item Signal type Contact type A contact (normally open) (1) Output 4 Function Contact output signal 4 B contact (normally closed) Select from Table 2.4-3 Signal type for contact output signal 4 to 6 [OFF] A contact (normally open) (2) Output 5 Function Contact output signal 5 B contact (normally closed) A contact (normally open) (3) Output 6 Function Contact output signal 6