20 30 40 Symbol Nil B* H* Symbol 02 03 04 *Note: Bracket and/or panel mount nut are not assembled and are supplied loose at time of shipment.
Model Optional specifications AW10(K) AW20P-270AS AR20P-260S AW20(K) AW30(K) AR40P-270AS AR40P-260S AW40(K) AW40(K)-06 AW60(K) AW60P-270AS Note 6) Bracket assembly Note 1) AR10P-270AS AR10P-260S G27-10-R1 G27-10-R1 Note 3) AR30P-270AS AR30P-260S Note 7) Set nut G36-10-01 G36-2-01 G36-10-01-L G36-2-01-L G46-10-02 G46-2-02 G46-10-02-L G46-2-02-L Round type Note 2) Standard 0.02 to 0.2 MPa
Tap water: Standard of The Japan Refrigeration And Air Conditioning Industry Association (JRA GL-02-1994) 15% ethylene glycol aqueous solution: diluted by tap water in condition above without any additives such as antiseptics.
Tap water: Standard of The Japan Refrigeration And Air Conditioning Industry Association (JRA GL-02-1994) 15% ethylene glycol aqueous solution: diluted by tap water in condition above without any additives such as antiseptics.
Tap water: Standard of The Japan Refrigeration And Air Conditioning Industry Association (JRA GL-02-1994) 15% ethylene glycol aqueous solution: diluted by tap water in condition above without any additives such as antiseptics.
Tap water: Standard of The Japan Refrigeration And Air Conditioning Industry Association (JRA GL-02-1994) 15% ethylene glycol aqueous solution: diluted by tap water in condition above without any additives such as antiseptics.
Tap water: Standard of The Japan Refrigeration And Air Conditioning Industry Association (JRA GL-02-1994) 15% ethylene glycol aqueous solution: diluted by tap water in condition above without any additives such as antiseptics.
Outside of the ambient temperature range AL36 Maintenance Maintenance alarm AL37 Refrigeration Circuit Compressor circuit failure AL38 Sensor Sensor failure AL39 Controller Controller failure AL40 Compressor Inverter Compressor inverter error AL41 Compressor Inverter Comm. Compressor inverter communication error AL42 Pump Inverter Pump inverter error AL43 Pump Inverter Comm.
Outside of the ambient temperature range AL36 Maintenance Maintenance alarm AL37 Refrigeration Circuit Compressor circuit failure AL38 Sensor Sensor failure AL39 Controller Controller failure AL40 Compressor Inverter Compressor inverter error AL41 Compressor Inverter Comm. Compressor inverter communication error AL42 CH1 Pump Inverter CH1 pump inverter error AL43 CH1 Pump Inverter Comm.
Outside of the ambient temperature range AL36 Maintenance Maintenance alarm AL37 Refrigeration Circuit Compressor circuit failure AL38 Sensor Sensor failure AL39 Controller Controller failure AL40 Compressor Inverter Compressor inverter error AL41 Compressor Inverter Comm. Compressor inverter communication error AL42 CH1 Pump Inverter CH1 pump inverter error AL43 CH1 Pump Inverter Comm.
Size: 1/2, Thread: M Thread, Rc(PT), Port Size: 3/4, Accessory: None, Option 1: 1000cm³ Tank w/Switch Lower Limit OFF, Option 2: Flow Direction: Right->Left
Size: 1/2, Thread: M Thread, Rc(PT), Port Size: 3/4, Accessory: Bracket, Option 1: 1000cm³ Tank w/Switch Lower Limit OFF, Option 2: Flow Direction: Right->Left
Size: 1/2, Thread: M Thread, Rc(PT), Port Size: 1/2, Accessory: Bracket, Option 1: 1000cm³ Tank w/Switch Lower Limit OFF, Option 2: Flow Direction: Right->Left
Size: 1/2, Thread: M Thread, Rc(PT), Port Size: 1/4, Accessory: Bracket, Option 1: 1000cm³ Tank w/Switch Lower Limit OFF, Option 2: Flow Direction: Right->Left
Size: 1/2, Thread: M Thread, Rc(PT), Port Size: 1/2, Accessory: None, Option 1: 1000cm³ Tank w/Switch Lower Limit OFF, Option 2: Flow Direction: Right->Left
Size: 40 (1/2), Thread: M Thread, Rc(PT), Port Size: 06 (3/4), Accessory: None, Option 1: 11 (1000cm³ Tank w/Switch Lower Limit OFF), Option 2: R (Flow Direction: Right->Left)
Size: 40 (1/2), Thread: M Thread, Rc(PT), Port Size: 06 (3/4), Accessory: B (Bracket), Option 1: 11 (1000cm³ Tank w/Switch Lower Limit OFF), Option 2: R (Flow Direction: Right->Left)
Size: 40 (1/2), Thread: M Thread, Rc(PT), Port Size: 04 (1/2), Accessory: B (Bracket), Option 1: 11 (1000cm³ Tank w/Switch Lower Limit OFF), Option 2: R (Flow Direction: Right->Left)
Size: 40 (1/2), Thread: M Thread, Rc(PT), Port Size: 02 (1/4), Accessory: B (Bracket), Option 1: 11 (1000cm³ Tank w/Switch Lower Limit OFF), Option 2: R (Flow Direction: Right->Left)
Size: 40 (1/2), Thread: M Thread, Rc(PT), Port Size: 04 (1/2), Accessory: None, Option 1: 11 (1000cm³ Tank w/Switch Lower Limit OFF), Option 2: R (Flow Direction: Right->Left)