Ambient and fluid temperature (C) 5 to 60 (with no freezing) Applicable Model Applicable Model Model AR25 AR40 AR40-06 AR50 1/4, 3/8 AR30 1/4, 3/8 1/4, 3/8, 1/2 3/4 3/4, 1 AR60 Model AR20 AR40 AR40-06 AR50 1/8, 1/4 AR25 1/4, 3/8 AR30 1/4, 3/8 1/4, 3/8, 1/2 3/4 3/4, 1 AR60 Port size 1 Port size 1 30 AR X430 03 BG 30 AR X425 03 BG For high/low temperature Option/Semi-standard: Select one each
Applicable Model Model AW30 AW40 AW40-06 AW60 Port size 1/4, 3/8 1/4, 3/8, 1/2 3/4 3/4, 1 30 AW 2 03 BG X430 Option/Semi-standard: Select one each for a to g. Option/Semi-standard symbol: When more than one specification is required, indicate in alphanumeric order.
. 3-1 3.2 Connected explanation . 3-1 3.3 Communication specification . 3-2 3.4 MODBUS communication function . 3-3 3.5 Precautions for communication . 3-3 3.5.1 Precautions after wiring and before communication . 3-3 3.5.2 Precautions for communicating . 3-3 3.6 Setting and checking . 3-4 3.6.1 Setting and checking items . 3-4 3.6.2 Setting and checking . 3-5 3.7 Communication sequence
(A contact) or N.C. (B contact). Contact output signal 3 WRN alarm selects N.O. (A contact) or N.C. (B contact). (1) (2) (3) Setting of contact output signal 1 to 3 Table 5.4-28 Setting of contact output signal 1 to 3 No.
Sound noise:HRL100-A-20 : 75 dB(A) HRL200-A-20 : 75 dB(A) HRL300-A-20 : 71 dB(A) * Front 1m, height 1m, rated condition 3.2 Installation HRL Series 3-6 HRX-OM-Y098 Chapter 3 Transport and Setting Up 3.2.3 Installation and maintenance space It is recommended to keep the space around the product shown in Fig. 3-3.
Sound noise:HRL100-A-20 : 75 dB(A) HRL200-A-20 : 75 dB(A) HRL300-A-20 : 71 dB(A) * Front 1m, height 1m, rated condition 3.2 Installation HRL Series 3-6 HRX-OM-W060 Chapter 3 Transport and Setting Up 3.2.3 Installation and maintenance space It is recommended to keep the space around the product shown in Fig. 3-3.
(A contact) or N.C. (B contact). Contact output signal 3 WRN alarm selects N.O. (A contact) or N.C. (B contact). (1) (2) (3) Setting of contact output signal 1 to 3 Table 5.4-22 Setting of contact output signal 1 to 3 No.
Remove a housing from a body by rotating 4 mounting screws counterclockwise with a hexagon wrench key. Hexagon wrench key Nominal: 5 2) Remove the valve guide. Hold the valve guide with a spanner on the spanner flat to rotate it counterclockwise and remove the valve guide. Spanner Nominal: 30 3) Remove the valve spring. 4) Remove the valve assembly.
Remove a housing from a body by rotating 4 mounting screws counterclockwise with a hexagon wrench key. Hexagon wrench key Nominal: 5 2) Remove the valve guide. Hold the valve guide with a spanner on the spanner flat to rotate it counterclockwise and remove the valve guide. Spanner Nominal: 30 3) Remove the valve spring. 4) Remove the valve assembly.
In case of facility having a small installation area (that can not vent the air naturally) Make a forced air exhaust vent on a wall at a high level and an air inlet on a wall at a low level. 3.
Table 3-3 Power supply cable and Earth Leakage BreakerRecommended Recommended earth Terminal block leakage breaker Power screw Recomm Tighten Sensiti Rated Model supply Cable qty. x size diamet ended ing Rated vity curren voltage er crimp torque voltage of leak t terminal [V] current [A] [mA] 3 cores x10AWG HRS060-A-20 30 (3 cores x 5.5mm2) (including ground) 200, 1-phase 1.5Nm M4 5.5-4 30
Rated Rated Sensitivity voltage x size voltage current of leak [V] [A] current [mA] 3 wires x14AWG HRS018-A-20-R HRS030-A-20-R 1-phase 10 30 (3 wires x 2.0mm2) 200, (including ground) Cable diameter: 8.5 to 11.5 mm 200-230V AC 230 HRS0-A-20-T-R (50/60Hz) (High pressure pump 15 30 [Optional]) HRS-R Series 3.3 Installation 3-9 HRX-OM-W058 Chapter 3 Transport and Setting Up 3.3.3 Preparation
2.4 Operation display panel . 2-4 Chapter 3 Transport and Setting Up . 3-1 3.1 Transport. 3-1 3.1.1 Transportation using casters . 3-2 3.2 Installation . 3-3 3.2.1 Environment . 3-4 3.2.2 Location (Required ventilation rate and facility water source) . 3-6 3.2.3 Installation and Maintenance Space . 3-7 3.3 Installation . 3-8 3.3.1 Mounting . 3-8 3.3.2 Electrical wiring . 3-9 3.3.3 Preparation
Terminal no.12 Switch Terminal no. 12 11 Recommended accessory cable dia. is 0.14 to 1.5mm2 10 9 Terminal no.1 Fig. 3-8 Wiring of contact for remote signal inputsExample 3.3 Installation HRS-R Series 3-14 HRX-OM-X027 Chapter 3 Transport and Setting Up 3. Inset the signal cable through the hole and fit the nipple A, nipple B and lock nut. Then fit the cap A, cap B and rubber bushing.
Table 3-3 Power supply cable and Earth Leakage BreakerRecommended Recommended earth leakage breaker Model Power supply Sensitivity voltage Cable qty. x size Rated Rated of leak voltage current current [V] [A] [mA] 1-phase 200-230V AC (50/60Hz) 3 cores x12AWG HRS040-A-20 200, Recomm 230 20 30 Terminal (3 cores x3.5mm2) HRS040-W-20 block ended (including ground) screw crimp diameter terminal
2.4 Operation display panel . 2-4 Chapter 3 Transport and Setting Up . 3-1 3.1 Transport. 3-1 3.1.1 Transportation using casters . 3-2 3.2 Installation . 3-3 3.2.1 Environment . 3-4 3.2.2 Location (Required ventilation rate and facility water source) . 3-6 3.2.3 Installation and Maintenance Space . 3-7 3.3 Installation . 3-8 3.3.1 Mounting . 3-8 3.3.2 Electrical wiring . 3-9 3.3.3 Preparation
2.4 Operation display panel . 2-4 Chapter 3 Transport and Setting Up . 3-1 3.1 Transport. 3-1 3.1.1 Transportation using casters . 3-2 3.2 Installation . 3-3 3.2.1 Environment . 3-4 3.2.2 Location (Required ventilation rate and facility water source) . 3-6 3.2.3 Installation and Maintenance Space . 3-7 3.3 Installation . 3-8 3.3.1 Mounting . 3-8 3.3.2 Electrical wiring . 3-9 3.3.3 Preparation
T ground) HRSE012-A-20/23 1-phase 200V AC Lead wire end not Shared HRSE012-A-20/23-T (50/60Hz) 3 cores x 2.5mm2 treated with 100 V, 200 V HRSE018-A-20/23 (Bare cut) 15A 15A 30mA -23 Only (including HRSE018-A-20/23-T (L: Brown, N: Blue, PE:Green/Yellow) and 1-phase ground) HRSE024-A-20/23 230V 230V AC HRSE024-A-20/23-T (50/60Hz) HRSE Series 3.3 Installation 3-7 HRX-OM-R039 Chapter 3 Transport
10 For Options T, MT: 15 Applicable earth leakage breaker capacity8 Rated current: 10 A For Options T, MT: 15 A Sensitivity current: 30 mA Electrical system Cable quantity x Size (Including grounding cable)15 3 cores x 14 AWG (3 cores x 2.0 mm2) Rated operating current (50/60 Hz)17 [A] 3.6/4.0 3.6/4.3 5.2/5.8 5.5/6.2 For Options T, MT 4.7/6.2 4.7/6.5 6.3/8.0 6.5/8.3 Rated power consumption
Prepare a forklift. The product will be delivered in the packaging shown below. 3. Hanging transportation 1) Crane manipulation and slinging work should be done by an eligible person. 2) Do not grip the piping on the right side or the handles of the panel. 3) When hanging by the eye bolts, be sure to use a 4-point hanging method.