Circulating fluid discharge pressure drop AL28 *2 High Electric Conductivity Electric conductivity increase AL29 No Power Supply Power supply error AL30 Digital Input 1 Contact input 1 signal detection AL31 Digital Input 2 Contact input 2 signal detection AL34 Communication Communication error AL35 Ambient Temp.
Standard Specifications AC20-A AC25-A AC30-A AC40-A AC40-06-A Model AF40-06-A AR40-06-A AL40-06-A AF40-A AR40-A AL40-A AF30-A AR30-A AL30-A AF30-A AR25-A AL30-A AF20-A AR20-A AL20-A Air filter Regulator Lubricator Component Port size Pressure gauge port size Fluid 3/4 1/8, 1/4 1/4, 3/8 1/8 1/4, 3/8 1/4, 3/8, 1/2 Air 5 to 60C (with no freezing) 1.5 MPa 1.0 MPa 0.05 to 0.7 MPa 5 m Class 1
Size 20 30 40 Symbol 02 03 04 Description None Mounting Bracket Float Auto Drain (N.C.)
Ambient and fluid temperature (C) 5 to 60 (with no freezing) Applicable Model Applicable Model Model AR25 AR40 AR40-06 AR50 1/4, 3/8 AR30 1/4, 3/8 1/4, 3/8, 1/2 3/4 3/4, 1 AR60 Model AR20 AR40 AR40-06 AR50 1/8, 1/4 AR25 1/4, 3/8 AR30 1/4, 3/8 1/4, 3/8, 1/2 3/4 3/4, 1 AR60 Port size 1 Port size 1 30 AR X430 03 BG 30 AR X425 03 BG For high/low temperature Option/Semi-standard: Select one each
-X425 Proof pressure (MPa) 3.0 Maximum operating pressure (MPa) 2.0 Set pressure range (MPa) 0.1 to 1.6 Ambient and fluid temperature (C) 5 to 60C (with no freezing) Applicable Model Model AW20 AW40 AW40-06 AW60 1/8, 1/4 AW30 AW30-03-2-X425 Port size 1/4, 3/8 1/4, 3/8, 1/2 3/4 3/4, 1 30 AW X425 2 03 BG Option/Semi-standard: Select one each for a to f.
Abnormal function code: 841000 0100 ASCII code 38h, 34h Example 2) RTU mode Receive function code: "04" (0 0100) Abnormal function code: "84" (1000 0100 3.12 Negative response HRR Series 3-16 HRX-OM-W004 Chapter 3 Serial communication 2) Error Code Assign error code below. 01 : Function code of a command is outside the standard 02 : The specified address of register is outside the range. 03
Size: 3/8, Thread: M Thread, Rc(PT), Port Size: 1/4, Accessory: None, Option 1: 1000cm³ Tank w/Switch Lower Limit OFF, Option 2: Flow Direction: Right->Left
Size: 3/8, Thread: M Thread, Rc(PT), Port Size: 1/4, Accessory: Bracket, Option 1: 1000cm³ Tank w/Switch Lower Limit OFF, Option 2: Flow Direction: Right->Left
Size: 30 (3/8), Thread: M Thread, Rc(PT), Port Size: 02 (1/4), Accessory: None, Option 1: 11 (1000cm³ Tank w/Switch Lower Limit OFF), Option 2: R (Flow Direction: Right->Left)
Size: 30 (3/8), Thread: M Thread, Rc(PT), Port Size: 02 (1/4), Accessory: B (Bracket), Option 1: 11 (1000cm³ Tank w/Switch Lower Limit OFF), Option 2: R (Flow Direction: Right->Left)
Size: 30 (3/8), Thread: F (G), Port Size: 03 (3/8), Accessory: B (Bracket), Option 1: 11 (1000cm³ Tank w/Switch Lower Limit OFF), Option 2: R (Flow Direction: Right->Left)
M5 thread OUT IN Symbol Plate PEEK PEEK PEEK Diaphragm EPDM FKM Kalrez A B C 11R 2 N.C. (Symbol 1) IN (Symbol 2) OUT Option Nil Nil Bracket Manual override Bracket, Manual override 1 2 3 12R N.O.
) Detection of contact input signal Setting for alarm (AL30 and AL31) Setting for contact output signal 1 to 3 Analog output setting Contact input signal setting Serial communication setting HRL Series 5.4 Description of Screen 5-51 HRX-OM-W060 Chapter 5 Display and Setting of Various Functions Setting for communication error (AL34)/contact input signal detection (AL30 and AL31) 1.
input signal detection (AL30 and AL31) 1.
error (AL34)/contact input signal detection (AL30 and AL31) 1.
and Setting of Various Functions Setting for communication error (AL34)/contact input signal detection (AL30 and AL31) 1.
Tightening torque AL20: 0.3 0.05 Nm AL30: 0.4 0.05 Nm AL40 to 60: 0.55 0.05 Nm Flat blade screw driver (Torque driver) Actuators Modular F.R.L.
Tightening torque AL20: 0.3 0.05 Nm AL30: 0.4 0.05 Nm AL40 to 60: 0.55 0.05 Nm Flat blade screw driver (Torque driver) Actuators Modular F.R.L.
AL292 Fan maintenance OFF Every 30,000h AL30 Compressor maintenance OFF Every 30,000h AL31 Contact input 1 signal detection A.STP Contact input is detected. AL32 Contact input 2 signal detection A.STP AL37 Compressor discharge temp. sensor failure P.RUN Malfunction of the temperature sensor occurred. Ask for the service.
*For air-cooled type Compressor maintenance (AL30): Generated after 50,000h of accumulated operating time To reset the alarm, reset the accumulated operating time.