Table 3-3 Power supply cable and Earth Leakage BreakerRecommended Recommended earth Terminal block leakage breaker Power screw Recomm Tighten Sensiti Rated Model supply Cable qty. x size diamet ended ing Rated vity curren voltage er crimp torque voltage of leak t terminal [V] current [A] [mA] 3 cores x10AWG HRS060-A-20 30 (3 cores x 5.5mm2) (including ground) 200, 1-phase 1.5Nm M4 5.5-4 30
Table 3-3 Power supply cable and Earth Leakage BreakerRecommended Recommended earth leakage breaker Model Power supply Sensitivity voltage Cable qty. x size Rated Rated of leak voltage current current [V] [A] [mA] 1-phase 200-230V AC (50/60Hz) 3 cores x12AWG HRS040-A-20 200, Recomm 230 20 30 Terminal (3 cores x3.5mm2) HRS040-W-20 block ended (including ground) screw crimp diameter terminal
2.4 Operation display panel . 2-4 Chapter 3 Transport and Setting Up . 3-1 3.1 Transport. 3-1 3.1.1 Transportation using casters . 3-2 3.2 Installation . 3-3 3.2.1 Environment . 3-4 3.2.2 Location (Required ventilation rate and facility water source) . 3-6 3.2.3 Installation and Maintenance Space . 3-7 3.3 Installation . 3-8 3.3.1 Mounting . 3-8 3.3.2 Electrical wiring . 3-9 3.3.3 Preparation
2.4 Operation display panel . 2-4 Chapter 3 Transport and Setting Up . 3-1 3.1 Transport. 3-1 3.1.1 Transportation using casters . 3-2 3.2 Installation . 3-3 3.2.1 Environment . 3-4 3.2.2 Location (Required ventilation rate and facility water source) . 3-6 3.2.3 Installation and Maintenance Space . 3-7 3.3 Installation . 3-8 3.3.1 Mounting . 3-8 3.3.2 Electrical wiring . 3-9 3.3.3 Preparation
Prepare a forklift. The product will be delivered in the packaging shown below. 3. Hanging transportation 1) Crane manipulation and slinging work should be done by an eligible person. 2) Do not grip the piping on the right side or the handles of the panel. 3) When hanging by the eye bolts, be sure to use a 4-point hanging method.
For a facility having a small installation area (that can not vent the air naturally): Make a forced air exhaust vent on a wall at a high level and an air inlet on a wall at a low level. 3.
T ground) HRSE012-A-20/23 1-phase 200V AC Lead wire end not Shared HRSE012-A-20/23-T (50/60Hz) 3 cores x 2.5mm2 treated with 100 V, 200 V HRSE018-A-20/23 (Bare cut) 15A 15A 30mA -23 Only (including HRSE018-A-20/23-T (L: Brown, N: Blue, PE:Green/Yellow) and 1-phase ground) HRSE024-A-20/23 230V 230V AC HRSE024-A-20/23-T (50/60Hz) HRSE Series 3.3 Installation 3-7 HRX-OM-R039 Chapter 3 Transport
40 A 4 cores x 8 mm2 (4 cores x AWG8) (Including grounding cable) R8-5 HRSH250--20 50 A 4 cores x 8 mm2 (4 cores x AWG8) (Including grounding cable) R8-5 M5 A HRSH100--40 20 A 3 x 5.5 mm2 (3 x AWG10) (Power supply) 1 x 14 mm2 (1 x AWG6) (Grounding cable) R5.5-5 (Power supply) R14-5 (Grounding cable) HRSH150--40 HRSH200--40 HRSH250--40 3-phase 380 to 415 VAC (50/60 Hz) 30 A Note) An example
Cable size Crimped terminal on the thermo-chiller side Applicable model HRS100-A -20HRS100-W -204 cores x 5.5 mm2 (4 cores x AWG10) (Including grounding cable R5.5-5) R5.5-5 3-phase 200 VAC (50 Hz) 3-phase 200 to 230 VAC (60 Hz) 30 A M5 HRS150-A -20HRS150-W -2040 A 4 cores x 8 mm2 (4 cores x AWG8) (Including grounding cable R8-5) R8-5 A HRS100-A -40HRS100-W -403-phase 380 to 415 VAC (50/60
phase 200 VAC (50 Hz), 3-phase 200 to 230 VAC (60 Hz) 3-phase 380 to 415 VAC (50 Hz/60 Hz) HRS100 Water-cooled 10.0/11.0 refrigeration HRS150 14.5/16.5 94 A Thermo-chiller Standard Type HRS100/150 Series Circulating Fluid Temperature Controller Circulating fluid can be heated without a heater. * For HRS150-A-20 Heating method using discharged heat makes a heater unnecessary.
A 24 VDC output can be also provided, and is available for a flow switch (SMCs PF2W etc.). Ex. 1 Ex. 2 Ex. 3 Remote signal I/O through serial communication The remote operation is enabled (to start and stop) through serial communication.
How To Order Lubricator Series AL20 to 40 AL 20 N 02 B X480 Z 2 Lubricator With External Epoxy Coating, Stainless Fasteners Body Size Symbol 20 30 40 Name Plate, Caution Plate On Bowl in psi, F Size 1/8 3/8 1/2 Bowl Applicable Body Size 20 30, 40 NPT Threads Description Metal Bowl Metal Bowl with Sight Glass Symbol 2 8 Port Size Symbol 02 03 04 Accessories Applicable Body Size 20 30 40 Port
How To Order Lubricator Series AL20 to 40 AL 20 N 02 B X480 Z 2 Lubricator With External Epoxy Coating, Stainless Fasteners Body Size Symbol 20 30 40 Name Plate, Caution Plate On Bowl in psi, F Size 1/8 3/8 1/2 Bowl Applicable Body Size 20 30, 40 NPT Threads Description Metal Bowl Metal Bowl with Sight Glass Symbol 2 8 Port Size Symbol 02 03 04 Accessories Applicable Body Size 20 30 40 Port
A licensed driver should drive the forklift. 2. Insert the fork to the place specified on the label. The fork should reach through to the other side of the product. 3. Be careful not to bump the fork to the cover panel or piping ports. Ventilation 3.
Fluid contact material Stainless steel, Copper (Heat exchanger brazing), Bronze, Brass, Ceramic, Carbon, PP , PE, POM, EPDM, PVC Power supply Single-phase 100 VAC 50/60 Hz Allowable voltage range 10% Fuse A 15 Power cable size Note 10) 3 cores x 14 AWG (2.0 mm2), 3 m Electrical system Applicable earth leakage breaker capacity Note 7) A 15 Rated operating current (50/60 Hz) Note 3) A 7.1/
of a command is not normal. 3.12 Negative response HRS400-A-46 3-16 DOC1003626 Chapter 3 Serial communication Communication example Device Address: No.1 Read seven consecutive data from register 0100h which is out of range.
Analog output 2 1 Signal the contents of the contact output 1 to 3 is a fixed value.
Chapter 3 Serial communication . 3-1 3.1 Precautions wiring communication . 3-1 3.2 Connected explanation . 3-1 3.3 Communication specification . 3-2 3.4 MODBUS communication function . 3-3 3.5 Precautions for communication . 3-4 3.5.1 Precautions after wiring and before communication . 3-4 3.5.2 Precautions for communicating . 3-4 3.6 Setting method . 3-5 3.7 Communication sequence . 3-
Standard Specifications AC20-A AC25-A AC30-A AC40-A AC40-06-A Model AF40-06-A AR40-06-A AL40-06-A AF40-A AR40-A AL40-A AF30-A AR30-A AL30-A AF30-A AR25-A AL30-A AF20-A AR20-A AL20-A Air filter Regulator Lubricator Component Port size Pressure gauge port size Fluid 3/4 1/8, 1/4 1/4, 3/8 1/8 1/4, 3/8 1/4, 3/8, 1/2 Air 5 to 60C (with no freezing) 1.5 MPa 1.0 MPa 0.05 to 0.7 MPa 5 m Class 1
Remove a housing from a body by rotating 4 mounting screws counterclockwise with a hexagon wrench key. Hexagon wrench key Nominal: 5 2) Remove the valve guide. Hold the valve guide with a spanner on the spanner flat to rotate it counterclockwise and remove the valve guide. Spanner Nominal: 30 3) Remove the valve spring. 4) Remove the valve assembly.