61 V Rib Mounting plate thickness 7 mm or less D m: A (Brass), N (Brass + Electroless nickel plating) H1 E H2 M T Plug: KQ2P Applicable fitting size d Model D L A Weight [g] 2 KJP-02 3 17 5.1 0.1 3.2 KQ2P-23 5 31.5 18.2 1 4 KQ2P-04 6 32 18.7 1 6 KQ2P-06 8 35 21.7 1 8 KQ2P-08 10 39 24.8 2 10 KQ2P-10 12 43 27.4 3.5 12 KQ2P-12 14 45.5 28.5 5 16 KQ2P-16 20.9 47 26.4 8 A L D d Applicable fitting
Caution Mounting screw tightening torques d M2: 0.15Nm M3: 0.6Nm M4: 1.4Nm D A L Dimensions Applicable fitting size d 4 Model A L D KQ2P-04 16 32 6 6 KQ2P-06 18 35 8 8 KQ2P-08 20.5 39 10 10 KQ2P-10 22 43 12 12 KQ2P-12 24 45.5 14 89 Type 41 42 Type 41P 42P Manifold spec. sheets Order made Type 45 Type 45Single valve A NA Features Precautions Type43 Type43P Manifold Options Single valve Type
D-A90(V)/D-A93(V)/D-A96(V) Direct Mounting Style .
200 V, 12 V, 24 V, 48 V, 110 V, 220 V 240 V With surge voltage suppressor (S) (Grommet type) With light/surge voltage suppressor (Z) (Grommet terminal) (Conduit terminal) (DIN terminal) L plug connector M plug connector Electrical Entry DC/ 24 V, 6 V, 12 V 48 V, 100 V 110 V ( Option) Grommet (G) Grommet terminal (E) Conduit terminal (T) DIN terminal (D), (Y) L plug connector (L) M plug connector
None Common to all voltages SY100-82-1 With indicator light Rated voltage Voltage symbol Part no. 24 V 12 V 24 VDC 12 VDC SY100-82-3-05 SY100-82-3-06 SY100-82-2-01 SY100-82-2-02 SY100-82-2-03 SY100-82-2-04 2.
mounting D U Symbol A, B P , EA, EB D side mounting SY Passage Porting specifications (A, B) EA, EB P 03 04 M Mixed 3 8 Symbol 1 2 1 2 SV 1 2 Side Bottom D side For bottom ported: Rc 3/8 only.
1/4 V V V V V V V AS3ll1FSl-l03 3/8 V V V V V V V AS-FP AS4ll1FSl-l04 1/2 V V VNote 4) V V 10 AS2ll1FSl-G01 1/8 V V V V VNote 4) AS-FM AS2ll1FSl-G02 1/4 VNote 4) V V V V AS-D AS3ll1FSl-G02 1/4 V V V V G Face seal AS3ll1FSl-G03 3/8 V V V V AS-T AS4ll1FSl-G04 1/2 V V VNote 4) Note 1) Without sealant type can be selected as a standard option.
E R S E R I E S ADH 4000 H E A V Y A U T O D R A I N S Y M B O L S ADH4 00 04 T H R E A D .Rc(PT) N .NPT M A X.
AS3ll1FSGl-l02 1/4 V V V V V V V AS3ll1FSGl-l03 3/8 V V V V V V V AS-FP AS4ll1FSGl-l04 1/2 V V VNote 4) V V 10 AS2ll1FSGl-G01 1/8 V V V V VNote 4) AS-FM AS2ll1FSGl-G02 1/4 VNote 4) V V V V AS-D AS3ll1FSGl-G02 1/4 V V V V G Face seal AS3ll1FSGl-G03 3/8 V V V V AS-T AS4ll1FSGl-G04 1/2 V V VNote 4) Note 1) Without sealant type can be selected as a standard option.
Applicable bore size (mm) D B1 C d H1 (mm) Part no.
Wide range of interchangeability (D-sub connector (25P) conforming to MIL standard) Quick wiring permits easier installation. 01F VV5FR5 1 D 06 04 Series VFR5000 Manifold Thread type Nil Rc Plug-in type with D-sub connector G F U side N NPT Connector mounting direction Stations NPTF T 02 2 stations Symbol Port size D side mounting U side mounting D U A, B P , EA, EB Symbol 04 06 08 Passage
D-M9N(V)/D-M9P(V)/D-M9B(V) Auto Switch Specifications Grommet PLC: Programmable Logic Controller 2-wire load current is reduced (2.5 to 40 mA).
Applicable bore size (mm) D B1 C d H1 (mm) Part no.
Output circuit Surge voltage 24 V 0 V Polarity protection diode Diode sol.1: Energized 60 V R Internal circuit Internal circuit Surge voltage Red (+) Coil 0 V PWM circuit sol.2: Deenergized 60 V R Surge voltage 24 V 0 V LED Large capacity load: Energized Black () 60 V R
) V V CC-LINK V D side U side 1 2 3 Stations SI Unit Part No.
Note 3) ZP3B-T2B(JB/K)20-B5 ZP3-(04/06/08)UM; ZP3-(04/06/08)B; ZP3-(04/06/08)UM; ZP3-(04/06/08)B; ZP3-(04/06/08)UM; ZP3-(04/06/08)B; ZP3-(04/06/08)UM; ZP3-(04/06/08)B; ZP3-(04/06/08)UM; ZP3-(04/06/08)B; ZP3-T(04/06/08)UM;(J/K)3-@ ZP3-T(04/06/08)B;(J/K)3-@ ZP3-T(04/06/08)UM;(J/K)6-@ ZP3-T(04/06/08)B;(J/K)6-@ ZP3-T(04/06/08)UM;(J/K)10-@ ZP3-T(04/06/08)B;(J/K)10-@ ZP3-T(04/06/08)UM;(JB/K)15-
VFS VS VS7 Dimensions VQ7 Applicable fitting size d 4 Model A L D Flat ribbon cable connector assembly KQ2P-04 16 32 6 6 KQ2P-06 18 35 8 8 KQ2P-08 20.5 39 10 10 KQ2P-10 22 43 12 Cable length (L) Assembly part no.
Note 3) ZP3B-T2B(JB/K)20-B5 ZP3-(04/06/08)UM; ZP3-(04/06/08)B; ZP3-(04/06/08)UM; ZP3-(04/06/08)B; ZP3-(04/06/08)UM; ZP3-(04/06/08)B; ZP3-(04/06/08)UM; ZP3-(04/06/08)B; ZP3-(04/06/08)UM; ZP3-(04/06/08)B; ZP3-T(04/06/08)UM;(J/K)3-@ ZP3-T(04/06/08)B;(J/K)3-@ ZP3-T(04/06/08)UM;(J/K)6-@ ZP3-T(04/06/08)B;(J/K)6-@ ZP3-T(04/06/08)UM;(J/K)10-@ ZP3-T(04/06/08)B;(J/K)10-@ ZP3-T(04/06/08)UM;(JB/K)15-
Note 3) ZP3B-T2B(JB/K)20-B5 ZP3-(04/06/08)UM; ZP3-(04/06/08)B; ZP3-(04/06/08)UM; ZP3-(04/06/08)B; ZP3-(04/06/08)UM; ZP3-(04/06/08)B; ZP3-(04/06/08)UM; ZP3-(04/06/08)B; ZP3-(04/06/08)UM; ZP3-(04/06/08)B; ZP3-T(04/06/08)UM;(J/K)3-@ ZP3-T(04/06/08)B;(J/K)3-@ ZP3-T(04/06/08)UM;(J/K)6-@ ZP3-T(04/06/08)B;(J/K)6-@ ZP3-T(04/06/08)UM;(J/K)10-@ ZP3-T(04/06/08)B;(J/K)10-@ ZP3-T(04/06/08)UM;(JB/K)15-
Note 3) ZP3B-T2B(JB/K)20-B5 ZP3-(04/06/08)UM; ZP3-(04/06/08)B; ZP3-(04/06/08)UM; ZP3-(04/06/08)B; ZP3-(04/06/08)UM; ZP3-(04/06/08)B; ZP3-(04/06/08)UM; ZP3-(04/06/08)B; ZP3-(04/06/08)UM; ZP3-(04/06/08)B; ZP3-T(04/06/08)UM;(J/K)3-@ ZP3-T(04/06/08)B;(J/K)3-@ ZP3-T(04/06/08)UM;(J/K)6-@ ZP3-T(04/06/08)B;(J/K)6-@ ZP3-T(04/06/08)UM;(J/K)10-@ ZP3-T(04/06/08)B;(J/K)10-@ ZP3-T(04/06/08)UM;(JB/K)15-