This is a legacy product, and replaced byAFD40-F03D-A, MICRO MIST SEPARATOR MODULAR, AIRLINE EQUIPMENT, AFD MASS PRO, EA, AFD MASS PRO 3/8 MODULAR (PT), 1.31332 lb
This is a legacy product, and replaced byAFD30-F03D-A, MICRO MIST SEPARATOR MODULAR, AIRLINE EQUIPMENT, AFD MASS PRO, EA, AFD MASS PRO 3/8 MODULAR (PT), .79366 lb
-D E410R-D 20 51 71 AC30-D, AC40-D B A C Caution on Mounting Pipe threads are not provided on the face which connects with the other components.
Model AC20, AR20, AR20K, AW20, AW20K, AWM20, AWD20 AR20P-580AS AC25, AR25, AR25K AR25P-580AS AC30, AR30, AR30K, AW30, AW30K, AWM30, AWD30 AR30P-580AS AC40(-06), AR40(-06), AR40K(-06), AW40(-06), AW40K(-06), AWM40, AWD40 AR40P-580AS 3.
D Center of F.R.L. body B C AC-A Seal A (Spacer width) AC-B Model A B C D Applicable model Y100-A 6 17.9 9 35.4 AC10-A Y200-A 3.2 31.2 15.6 44.9 AC20-A Y300-A 4.2 43.4 21.7 57.9 AC25-A, AC30-A Y400-A 5.2 53 26.5 68.5 AC40-A Y500-A 5.2 57 28.5 75.6 AC40-06-A Y200-A Y400-A Replacement Parts Description Material Part no.
Port size Attachment Body size Port size Symbol Port size for intermediate air release Symbol Description Attachment mounting position Applicable model 20 25 30 40 50 55 60 01 02 03 04 06 10 1/8 1/4 3/8 1/2 3/4 1 Nil None AF+AR+[K]+AL AC20 to 40 AC20: 1/8 AC25: 1/4 AC30: 1/4 AC40: 3/8 AW+[K]+AL AC20A to 40A K Check valve AF+[T]+AR+AL AC20 to 60 AC20: 1/8 AC25: 1/4 AC30: 1/4 AC40: 3/8 AC50
Model AC20, AR20, AR20K, AW20, AW20K, AWM20, AWD20 AR20P-580AS AC25, AR25, AR25K AR25P-580AS AC30, AR30, AR30K, AW30, AW30K, AWM30, AWD30 AR30P-580AS AC40(-06), AR40(-06), AR40K(-06), AW40(-06), AW40K(-06), AWM40, AWD40 AR40P-580AS 3.
Port size Attachment Body size Port size Symbol Port size for intermediate air release Attachment mounting position 20 25 30 40 50 55 60 Symbol Applicable model Description 01 02 03 04 06 10 1/8 1/4 3/8 1/2 3/4 1 Nil None AC20: 1/8 AC25: 1/4 AC30: 1/4 AC40: 3/8 AC20: 1/8 AC25: 1/4 AC30: 1/4 AC40: 3/8 AC50: 3/8 AC55: 1/2 AC60: 1/2 AC20 to 40 AF+AR+[K]+AL K Check valve AC20A to 40A AW+[K]
Model AC20, AR20, AR20K, AW20, AW20K, AWM20, AWD20 AR20P-580AS AR25P-580AS AC25, AR25, AR25K AC30, AR30, AR30K, AW30, AW30K, AWM30, AWD30 AR30P-580AS AC40(-06), AR40(-06), AR40K(-06), AW40(-06), AW40K(-06), AWM40, AWD40 AR40P-580AS e Tighten the bolt.
AKM2000-A AKM3000-A AKM4000-A AKM2000-A AC20-A, AC20A-A 40 28 11 40 11 1/8, 1/4 AC25-A AC30-A, AC30A-A AKM3000-A 53 34 14 48 13 1/8, 1/4 IN OUT B AC40-A, AC40A-ANote) AKM4000-A 1/4, 3/8 70 42 18 54 15 C Note) A pressure switch cannot be mounted on the AC40-06-A.
Example) AC30-F03DE1-KSTV-136NR-B q Nq Body size 20 25 30 40 50 55 60 Symbol Description Nw Pipe thread type Nil Rc N1 NPT F2 G + 01 1/8 02 1/4 03 3/8 04 1/2 06 3/4 10 1 + Ne Port size Nil Without auto drain C4 N.C. (Normally closed) Drain port is closed when pressure is not applied. D5 N.O.
Applicable Procedure model Work category Tool Criteria AC20 AC30 AC40 AC50 AC60 Disassembly 1) Untighten the two hexagon socket head cap screws with a hexagon wrench to loosen the retainer A. Hexagon wrench Nominal size: AC20-D 2 AC30-D 3 AC40-D AC50-D 4 AC60-D 2) Remove the product.
Example AC30-03DM-KSTV-13NR-A AC 30 03 DG 1N A F 1N 1 3 4 5 6 2 1 Symbol Description Body size 10 20 25 30 40 Nil Metric thread (M5) c Pipe thread type 2 Note 1) Note 2) Port size 3 Nil Without auto drain a Float type auto drain N.C. (Normally closed) Drain port is closed when pressure is not applied. Note 4) Note 3) N.O.
SPARE PARTS LIST Air combination AC junction Description Spare parts part number AC50*-B AC10*-A AC20*-B AC25*-B AC30*-B AC40*-B AC40*-06-B AC60*-B AC55*-B Packing Note 1Y120P-050AS Note 2Y220P-050S Y320P-050S Y420P-050S Y520P-050S Y620P-050S Note1) Refer to "10DISASSEMBLY DRAWING" on page 21 to 22 for Packing.
Unit Series AV2000-A AV3000-A AV4000-A AV5000-A Spacer Y200-A Y300-A Y400-A Y600-A Spacer with bracket Y200T-A Y300T-A Y400T-A Y600T-A Applicable model AC20-A AC20-B AC25-A, AC30-A AC25-B, AC30-B AC40-A*1 AC40-B*1 AC50-B, AC55-B AC60-B *1 Except port size 06 Assembly Example eSpacer with bracket qSoft start-up valve Air combination wAC30-03G-A Assembly example Products do not come assembled
Unit Series AV2000-A AV3000-A AV4000-A AV5000-A Spacer Y200-A Y300-A Y400-A Y600-A Spacer with bracket Y200T-A Y300T-A Y400T-A Y600T-A Applicable model AC20-A AC20-B AC25-A, AC30-A AC25-B, AC30-B AC40-A*1 AC40-B*1 AC50-B, AC55-B AC60-B *1 Except port size 06 Assembly Example eSpacer with bracket qSoft start-up valve Air combination wAC30-03G-A Assembly example Products do not come assembled
AC50 AC40 AC25 AC30 AC20 SMC Corporation of America 10100 SMC Blvd., Noblesville, IN 46060 www.smcusa.com VHS20 VHS30 VHS40 VHS50 SMC Pneumatics (Canada) Ltd. www.smcpneumatics.ca (800) SMC.SMC1 (762-7621) e-mail: sales@smcusa.com An interface part is required if a spacer or spacer with bracket shown in the table below is attached to a modular FRL.
Recommended Torque Unit: Nm model AC20 AC30 AC40 AC50 AC60 Applicable Spacer with Bracket part no. Y200-T-D Y300-T-D Y400-T-D Y600-T-D Spacer part no. Y200-D Y300-D Y400-D Y600-D Torque 0.36 1.2 1.2 2.0 0.036 0.05 0.05 0.1 6.
Applicable air preparation equipment VHS20 VHS30 VHS40 VHS40-06 VHS50 Y200-A Y300-A Y400-A Y500-A Y600-A AC20-A AC25-A, AC30-A AC40-A AC40-06-A AC50, AC55 Note), AC60 Note) Y200T-A Y300T-A Y400T-A Y500T-A Y600T-A Note) VHS50 can be connected to AC55 and AC60.
INFORMATION Modular Connection Type Residual Pressure Relief 3 Port Solenoid Valve RoHS For connecting to F.R.L. units AC25-A AC30-A AC40-A VP500 IN OUT VP700 Allows for space saving and reduced piping labor.