Compared to the 25A-ZSE20(F), 25A-ZSE20B(F) adds a 2nd switch output, as well as an analog voltage or current output. The switch output responds within 1.5ms once the set pressure value is reached. Both vacuum and compound pressure ranges are offered. Secondary battery capability is achieved by providing a piping port in stainless steel rather than brass.
Compared to the 25A-ZSE20(F), the 25A-ZSE20A(F) adds a 2nd switch output, plus an analog voltage or current output. The switch output responds within 1.5ms once the set pressure value is reached. Both vacuum and compound pressure ranges are offered. Secondary battery capability is achieved by providing a piping port in stainless steel rather than brass.
2 x C3, C4, C6, M5 C3: 3.2 one-touch fitting C4: 4 one-touch fitting C6: 6 one-touch fitting M5: M5 thread 2n x C3, C4, C6, M5 C3: 3.2 one-touch fitting C4: 4 one-touch fitting C6: 6 one-touch fitting M5: M5 thread Dimensions Formula L1 = 11n + 20 n: Station (Maximum 24) n L 1 2 3 4 5 6 7 8 9 10 11 12 L1 L2 L3 97 130 152 31 42 53 64 75 86 108 119 141 125 150 175 50 62.5 75 87.5 100 125 112.5
0.5 m 1 m 3 m 5 m Socket side: Straight Plug side: Straight 010 050 1 m 5 m SSPS Socket side: Angle Plug side: Angle SAPA Connector specifications S A Straight Angle Cable core wire colors Terminal no.
Digital pressure switch ZSE20-*-*-M5-A1 Supply valve Circuit diagram -31No. TQ1230001-OM104-C 5.1.2. In case of ZXP712 Release valve V114(N.C.) Pilot valve for supply V114(N.C.) Digital pressure switch ZSE20-*-*-M5-A1 Supply valve Circuit diagram -32No. TQ1230001-OM104-C 5.2. Center of gravity 5.2.1.
17.5 17.5 SMC SMC R2 R1 5 3 3 5 R2 R1 PE PE 3 2-Rc 1/8 (Pilot EXH port) 3 2-Rc 1/8 (Pilot EXH port) 38 70 38 53 Formula L1 = 25n + 63, L2 = 25n + 76 n: Stations (Maximum 16 stations) Formula L1 = 25n + 63, L2 = 25n + 76 n: Stations (Maximum 16 stations) L n Dimensions L n Dimensions 8 263 276 L1 L2 7 238 251 8 263 276 L1 L2 6 213 226 7 238 251 5 188 201 6 213 226 4 163 176 5 188 201 3 138
1 Output 3-Screen Display High-Precision Digital Pressure Switch RoHS IP40 ZSE20(F)/ISE20 Series How to Order Rated pressure range ISE20 0.1 to 1 MPa M For positive pressure ISE20 M5 N For vacuum/ compound pressure ZSE20 N M M5 q w e r t y u q Rated pressure range e Unit specification w Output specification ZSE20 0 to 101 kPa ZSE20F 100 to 100 kPa Symbol Description N NPN open collector 1
1 Output RoHS 3-Screen Display High-Precision Digital Pressure Switch IP40 ZSE20(F)/ISE20 Series How to Order Rated pressure range ISE20 0.1 to 1 MPa M For positive pressure ISE20 M5 N For vacuum/ compound pressure ZSE20 N M M5 q w e r t y u q Rated pressure range e Unit specification w Output specification ZSE20 0 to 101 kPa ZSE20F 100 to 100 kPa Symbol Description N NPN open collector 1
Plate A Plug (M-3P) (2 pcs.)
ZP3PG20JT2SF-M-7A-X2 21 ZP3P-20JT2SF-WM ZP3P 32 JT2 SF ZP3PG32JT2SF-7A-X2 48 ZP3P-32JT2SF-W ZP3PA-T2JT-7A-X2 ZP3P 32 JT2 SF M ZP3PG32JT2SF-M-7A-X2 48 ZP3P-32JT2SF-WM ZP3P 20 JT5 SF ZP3PG20JT5SF-7A-X2 23 ZP3P-20JT5SF-WG ZP3PA-T1JT-7A-X2 ZP3P 25 JT5 SF ZP3PG25JT5SF-7A-X2 25 ZP3P-25JT5SF-WG ZP3P 32 JT5 SF ZP3PG32JT5SF-7A-X2 54 ZP3PA-T2JT-7A-X2 ZP3P-32JT5SF-WG Input the material symbol (N, S,
Panel mount adapter (Part No.: ZS-46-B) Panel mount adapter + Front protective cover (Part No.: ZS-46-D) Hysteresis "Nil" or M kPa ZSE20(F) : Arbitrary display These safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard with the labels of "Caution", "Warning" or "Danger".
) A (A port reguralation) B (B port reguralation) 3 8 1 2 AXT512-19A-1 AXT512-19A-2 Interface for reverse pressure R1, R2 Individual EXH spacer Interface speed control VV72-R2-04 AXT510-32A Main EXH back pressure block plate AXT512-25A AN110-01 Silencer for pilot EXH 1.19-22 VS7-8 Manifold/Dimensions L: Dimensions Common EXH n L L1 Equation n: stations L1=56n+64 L2=56n+80 n: stations L1=56n
Rated Vacuum Range: -101 to 0 kPa, Output Specification: N (NPN Open Collector 1 Output), Unit Specification: M (SI Unit Only), Piping Specification: M5 (M5 Female Thread), Option 1: L (Lead Wire w/Connector, 2m), Option 2: D (Panel Mount Adapter + Front Protection Cover)
For vacuum/ compound pressure ISA2 ZSE30A 01 N M Option 3 Note) Calibration certificate Nil Y K T Note) Operation manual ISE35 Symbol Rated pressure range ZSE30A ZSE30AF 0 to 101 kPa 100 to 100 kPa PSE Piping specifications IS 01 Note) All texts in both English and Japanese.
Series: 25A-ZSE20, Rated Pressure Range: 0 to -101 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specifications: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specifications: Female Thread, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Panel Mount Adapter, Operation Manual:
Series: 25A-ZSE20, Rated Pressure Range: 0 to -101 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specifications: SI Unit Only, Piping Specifications: Female Thread, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: -, Operation Manual: -
Series: 25A-ZSE20, Rated Pressure Range: -100 to 100 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specifications: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specifications: Female Thread, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Panel Mount Adapter + Front Protection
Series: 25A-ZSE20, Rated Pressure Range: 0 to -101 kPa, Output Specification: PNP Open Collector 2 Outputs + Copy Function, Unit Specifications: SI Unit Only, Piping Specifications: Female Thread, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Panel Mount Adapter, Operation Manual: -
Series: 25A-ZSE20, Rated Pressure Range: 0 to -101 kPa, Output Specification: NPN Open Collector 2 Outputs + Analog Current Output, Unit Specification: SI Unit Only, Piping Specification: Female Thread, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Bracket: -, Operation Manual: -
Series: 25A-ZSE20, Rated Pressure Range: 0 to -101 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: Female Thread, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Bracket: Panel Mount Adapter, Operation Manual: Operation Manual