Output Specification: NPN Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: Female Thread, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Bracket: Panel Mount Adapter, Operation Manual: -
1/8 (with M5 female threads) Panel mount + Front protective cover (ZS-24-C) R 1/8 M5 x 0.8 female threads F *When optional parts only are required, order with the part numbers inside ( ).
MGPM, MGPL, MGPA Common Dimensions (mm) P Standard stroke (mm) Bore size (mm) B C DA FA FB G GA GB H HA J K L MM ML NN OA OB OL Nil TN TF 42 46 53 53.5 G1/8 G1/8 29 33 37 37.5 6 8 10 10 7 7 8 9 6 6 8 7 26 30 36 42 10 10.5 11.5 11.5 7 7.5 9 10 58 64 83 93 12 16 20 25 M4 M4 M5 M5 13 15 18 21 13 15 18 21 18 22 24 30 M4 x 0.7 M5 x 0.8 M5 x 0.8 M6 x 1.0 10 12 13 15 M4 x 0.7 M5 x 0.8 M5 x 0.8
CL CL1 MLGC CNG MNB Proper tightening torque (Nm) 7 to 9 12 to 14 22 to 24 Connection thread size R 1/8 R 1/4 R 3/8 CNA Caution CNS 1. Be sure to connect the load to the plate section with the lock in an unlocked condition. If this is done in the locked state, it may cause damage to the lock mechanism.
CL CL1 MLGC CNG MNB Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Proper tightening torque (Nm) 7 to 9 12 to 14 22 to 24 Connection thread size R 1/8 R 1/4 R 3/8 CNA Caution CNS 1.
Bracket B MPa ISE20A ISE20A: 0.050 MPa/ZSE20A: 5.1 kPa/ ZSE20AF: 5.0 kPa "Nil" or M Hysteresis kPa ZSE20A(F) Safety Instructions ISE20A Delay time 1.5 ms or less Mounting with panel mount adapter Mount part (a) to the front of the body and fix it. Then insert the body with (a) into the panel until (a) comes into contact with the panel front surface.
Proper tightening torque Nm 7 to 9 12 to 14 22 to 24 Connection thread size R 1/8 R 1/4 R 3/8 Manual unlocking For 20 through 32 Preparing for Operation Manual unlocking bolt Lock ring Manual unlocking bolt Warning Locking direction Locking direction 1. Before starting operation from the locked position, be sure to restore air pressure to the B port in the pneumatic circuit.
Proper tightening torque Nm 7 to 9 12 to 14 22 to 24 Connection thread size R 1/8 R 1/4 R 3/8 Manual unlocking For 20 through 32 Preparing for Operation Manual unlocking bolt Lock ring Manual unlocking bolt Warning Locking direction Locking direction 1. Before starting operation from the locked position, be sure to restore air pressure to the B port in the pneumatic circuit.
MSQ Angle adjustment Range Figure 5 MSZ MSZ CRQ2X MSQX ad a ge ju Cl lt MRQ an st bo oc t r m nd en g k en tm wi in e us 10 10 se t r st on dj a ju an r on ti ot ad iti ta os ge at p ro er y nt io e b C e b n y is e ge n ad w d k an c ju lo t r C st in en g m bo st lt ju b ad M 0 ax 19 im e u ng m ra ro n ta tio Center position adjustment Table 2 R: Clockwise adjustment L: Counterclockwise
Female rod end Female Rod End [mm] [mm] Bore size A AL B1 C D E F H H1 JA JB KA MM NA Bore size A1 H MM 20 14.5 12 13 15.5 8 14 0 0.1 2 21 5 M4 x 0.7 depth 7 M4 x 0.7 depth 5.5 Width across flats 6 length 3.5 M8 x 1.25 24 20 8 6.5 M4 x 0.7 25 17.5 15 17 16.5 10 14 0 0.1 2 24 6 M5 x 0.8 depth 7.5 M5 x 0.8 depth 6 Width across flats 8 length 3.5 M10 x 1.25 27 25 8 6.5 M5 x 0.8 32 17.5 15 17
12 2.5 4 14 22.5 6 12 10 12 6 8 SB SC SA 43 62 18.5 27 1.8 2.2 Model Maximum adjustment dimension RJ MIW12-12 MIW20-20 Note) Observe the specified adjustment range when adjusting with a stroke adjuster. 9 Escapements Series MIW/MIS Dimensions MIS-D Scraper mounting thread 2-LA GC GB FC GD LB FA B JA 2-GA drill LC EB JB Mounting hole EA C D 2-M5 x 0.8 Attachment mounting thread 2-FE through
I = m + mL kgm 2 r Find the actual moment of inertia I.
I = m + mL kgm 2 r Find the actual moment of inertia I.
12 2.5 4 14 22.5 6 12 10 12 6 8 SB SC SA 43 62 18.5 27 1.8 2.2 Model Maximum adjustment dimension RJ MIW12-12 MIW20-20 Note) Observe the specified adjustment range when adjusting with a stroke adjuster. 9 Escapements Series MIW/MIS Dimensions MIS-D Scraper mounting thread 2-LA GC GB FC GD LB FA B JA LC 2-GA drill EB JB Mounting hole EA C D 2-M5 x 0.8 Attachment mounting thread 2-FE through
Series: 25A-ISE20, Rated Pressure Range: A (-0.1 to 1 MPa), Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: M5 (Female Thread), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: B (Panel Mount Adapter)
Series: 25A-ISE20, Rated Pressure Range: A (-0.1 to 1 MPa), Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: M5 (Female Thread), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: B (Panel Mount Adapter)
Series: 25A-ISE20, Rated Pressure Range: A (-0.1 to 1 MPa), Output Specification: S (NPN Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: M5 (Female Thread), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: B (Panel Mount Adapter)
Series: 25A-ISE20, Rated Pressure Range: -0.1 to 1 MPa, Output Specification: PNP Open Collector 2 Outputs + Copy Function, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: Female Thread, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Bracket: Panel Mount Adapter, Operation Manual: -
Series: 25A-ISE20, Rated Pressure Range: -0.1 to 1 MPa, Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: Female Thread, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Bracket: Panel Mount Adapter, Operation Manual: -
Series: 25A-ISE20, Rated Pressure Range: -0.1 to 1 MPa, Output Specification: NPN Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: Female Thread, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Bracket: Panel Mount Adapter, Operation Manual: -