Series: 25A-ISE20, Rated Pressure Range: -0.1 to 1 MPa, Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specifications: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 02 [R1/4, (M5, Female Threaded)], Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Panel Mount Adapter,
Compared to the 25A-ISE20, 25A-ISE20B adds a 2nd switch output, as well as an analog voltage or current output. The switch output responds within 1.5ms once the set pressure value is reached. Response time can be adjusted to reduce chattering. Secondary battery capability is achieved by providing a piping port in stainless steel rather than brass.
Compared to the 25A-ISE20, 25A-ISE20B adds a 2nd switch output, as well as an analog voltage or current output. The switch output responds within 1.5ms once the set pressure value is reached. Response time can be adjusted to reduce chattering. Secondary battery capability is achieved by providing a piping port in stainless steel rather than brass.
Bracket mounting inserts found on the standard ISE20A are omitted as well. 25A-ISE20A is UL/CSA, CE and RoHS compliant with an IP40 enclosure rating.
Bracket mounting inserts found on the standard ISE20A are omitted as well. 25A-ISE20A is UL/CSA, CE and RoHS compliant with an IP40 enclosure rating.
ISE20 : 0.500 MPa ZSE20 : -50.5 kPa ZSE20F: 50.0 kPa Bracket B Pressure Setting Default setting Units specification Pressure range ISE20 ISE20 : 0.050 MPa ZSE20 : 5.1 kPa ZSE20F: 5.0 kPa Safety Instructions MPa Mounting with panel mount adapter Mount part (a) to the front of the body and fix it.
Lead wire length symbols: 0.5 mNil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ Solid state auto switches marked with ? are produced upon receipt of order. Since there are other applicable auto switches then listed above, refer to page 23 for details.
Series: 25A-ISE20, Rated Pressure Range: A (-0.1 to 1 MPa), Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: M5 (Female Thread)
Series: 25A-ISE20, Rated Pressure Range: A (-0.1 to 1 MPa), Output Specification: S (NPN Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: M5 (Female Thread)
display unit Note 1) switching function Nil Without lead wire B Fixed SI unit Note 2) M Nil With display unit Note 1) switching function (Initial value psi) P Lead wire with connector (Lead wire length 2 m) Note) Made to Order Note 1) Under the New Measurement Law, sales of switches with the unit switching function have not been allowed for use in Japan.
size A B 2-P Port size A B M M 2-J, thread depth K 2-J, thread depth K G1/2 Specifications with bracket Orifice 2, 3, 4.5, 6 Orifice 8, 10 7.5 2.3 Bracket Y 29 Mounting hole 2-5.3 Bracket 22 5.5 52 28 W U 67 X (mm) Grommet Conduit DIN terminal Electrical entry Mounting dimensions Bracket mounting Port size P Model Orifice size A B C D E F H Conduit terminal J M4 M5 M5 M5 M5 K M Q R 50 60
T.T. 12 10 1 (P) 10.5 (37.1) (47.6) (A) 2 3 port 30 12 10 1 (P) 3 (R) 17 44 2 x 4.6 mounting hole 25.4 2 x M5 x 0.8 depth 4 14 8.5 * 0.5 MPa supply F.O.F.* 13 N P .T. 3.2 mm O.T. 2.3 mm T.T. 5.5 mm One way roller lever VM123-M5-02A VM133-M5-02A VM123-M5-02SA VM133-M5-02SA 10 Polyacetal or hard steel roller 46.5 29.2 (A) 2 Symbol 2 port 8 P.T. O.T. T.T.
B E C A P F Single rubber stopper M M G D A A MXQA-A27 Model Adjuster part no.
To SI To MOT Provided by the customer To PWR Power supply for controller 24 VDC Step data input type JXC51/61 Communication cable (3 m) p. 171 Power supply plug p. 171 p. 165 (Accessory) Options VCommunication cable for controller setting VConversion cable*2 VTeaching box p. 171 p. 171 p. 171 P5062-5 (0.3 m) Communication cable : JXC-W2A-C USB cable : LEC-W2-U (With 3 m cable) LEC-T1-3mGm
filter with manual drain P P P Regulator P P P P P P Air release valve P P P P P P Pressure switch P P Blanking plate (Air release valve) P P Blanking plate (Filter, Regulator) P Blanking plate (Pressure switch) P P P P P Thread type Nil Rc F G N NPT T NPTF Note) Electrical entry: Control unit can not be removed except L and C kits. 2 stations 2 stations 2 stations 2 stations 2 stations
a a1 (VXZ24, 26) Note) (44) 31.5 6.5 R C E 10.5 IN OUT 2 x M Depth 5 G A H 2 x P Port size B1 B (mm) A B B1 C D E F G Port size P H J M Model 3 A 4 B 5 C 6 D VXZ2 VXZ2 VXZ2 VXZ2 35 35 40 40 10.5 14 17 20 22 22 24.5 24.5 40 48 62 66 1/4, 3/8 1/2 3/4 1 35 35 33 37 10 14.2 15.2 17.2 M5 M5 M6 M6 21 <22> 28 33.5 42 57 70 71 95 28.5 37.5 38.5 49.5 85 (91.5) 93 (99.5) 104 (110.5) 110 (116) Bracket
M5 x 0.8 through hole 0.5MPa 0.35MPa (except 05) 0.45MPa (13,15 only) H M S 112 85.4 74 70 62 10 P ZM1 K5LZ-E15L-X235 26 30 Body type Conforms to the standard product.
Port size 2 x P Port size B A M M 2 x J thread depth K 2 x J thread depth K DIN terminal: D Conduit terminal: T S Q F 34 D Cable 6 to 12 (Q) F G1/2 D 25 Width across flats H Width across flats H T C M C R R E E (S) A 2 x P Port size A 2 x P Port size B B M 2 x J thread depth K G1/2 2 x J thread depth K (mm) Electrical entry Grommet Mounting dimension Model Orifice diameter Port size P A Q
W H T U Pin no. n LEC-CSNA-1 39 37.2 12.7 14 14 773 LECY M U Series Options cable type M LEC Y C 1 Cable length (L) Motor type Y AC servo motor L* 0.2 m J 0.5 m 1 1 m 3 3 m Cable description M MECHATROLINK-2cable U MECHATROLINK-3cable * Not available for the MECHATROLINK2cable. * LEC-CYM-l is JEPMC-W6002-ll-E manufactured by YASKAWA CONTROLS CO., LTD. * LEC-CYU-l is JEPMC-W6012-ll-E manufactured