Magnet: D (Built-in Magnet), Mounting Direction: B (Lateral Mounting), Bore Size: 6, Stroke: 8mm, Action: D (Double Acting), Rod End Thread: Rod End Female Thread (w/o Thread for ø4), Auto Switch: F8B--Solid State, Gen Purpose, 2 Wire, Vertical, Lead Wire or Prewired Connector: L (3m)
Cylinder (Tube) Inner Diameter(φ): 6, Stroke(mm): 8, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.15~0.7, Cushion: None, Auto Switches: F8B,
Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 8, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1~0.7, Cushion: None, Auto Switches: F8B,
Cylinder (Tube) Inner Diameter(φ): 6, Stroke(mm): 8, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.15~0.7, Cushion: None, Auto Switches: F8B,
Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 8, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1~0.7, Cushion: None, Auto Switches: F8B,
Number Of Fingers(pcs.): 2, Cylinder inner diameter(ø): 8, Port thread type: M screw, Stroke(mm): 8, Finger option: Basic type, Stroke adjuster: Not available, Scraper: Not available, Auto switch: F8B, Lead wire length(m): 3, Number of auto switches: 2 pcs. included, Connector Type: N/A, Made-to-order specifications: N/A
(Example) CDUJB8-15DM Applicable Auto Switches/Refer to pages 21 through to 23 for additional information on auto switches.
Magnet: D (Built-in Magnet), Mounting Direction: B (Lateral Mounting), Bore Size: 8, Stroke: 20mm, Action: D (Double Acting), Rod End Thread: M (Rod End Male Thread), Auto Switch: F8B--Solid State, Gen Purpose, 2 Wire, Vertical, Lead Wire or Prewired Connector: L (3m)
Magnet: D (Built-in Magnet), Mounting Direction: B (Lateral Mounting), Bore Size: 8, Stroke: 4mm, Action: D (Double Acting), Rod End Thread: M (Rod End Male Thread), Auto Switch: F8B--Solid State, Gen Purpose, 2 Wire, Vertical, Lead Wire or Prewired Connector: L (3m)
Magnet: D (Built-in Magnet), Mounting Direction: B (Lateral Mounting), Bore Size: 8, Stroke: 15mm, Action: D (Double Acting), Rod End Thread: Rod End Female Thread (w/o Thread for ø4), Auto Switch: F8B--Solid State, Gen Purpose, 2 Wire, Vertical, Lead Wire or Prewired Connector: L (3m)
Magnet: D (Built-in Magnet), Mounting Direction: B (Lateral Mounting), Bore Size: 8, Stroke: 10mm, Action: D (Double Acting), Rod End Thread: M (Rod End Male Thread), Auto Switch: F8B--Solid State, Gen Purpose, 2 Wire, Vertical, Lead Wire or Prewired Connector: L (3m)
Magnet: D (Built-in Magnet), Mounting Direction: B (Lateral Mounting), Bore Size: 8, Stroke: 10mm, Action: D (Double Acting), Rod End Thread: Rod End Female Thread (w/o Thread for ø4), Auto Switch: F8B--Solid State, Gen Purpose, 2 Wire, Vertical, Lead Wire or Prewired Connector: L (3m)
Magnet: D (Built-in Magnet), Mounting Direction: B (Lateral Mounting), Bore Size: 8, Stroke: 6mm, Action: D (Double Acting), Rod End Thread: Rod End Female Thread (w/o Thread for ø4), Auto Switch: F8B--Solid State, Gen Purpose, 2 Wire, Vertical, Lead Wire or Prewired Connector: L (3m)
Magnet: D (Built-in Magnet), Mounting Direction: B (Lateral Mounting), Bore Size: 8, Stroke: 20mm, Action: D (Double Acting), Rod End Thread: Rod End Female Thread (w/o Thread for ø4), Auto Switch: F8B--Solid State, Gen Purpose, 2 Wire, Vertical, Lead Wire or Prewired Connector: L (3m)
Magnet: D (Built-in Magnet), Mounting Direction: B (Lateral Mounting), Bore Size: 8, Stroke: 6mm, Action: D (Double Acting), Rod End Thread: M (Rod End Male Thread), Auto Switch: F8B--Solid State, Gen Purpose, 2 Wire, Vertical, Lead Wire or Prewired Connector: L (3m)
Magnet: D (Built-in Magnet), Mounting Direction: B (Lateral Mounting), Bore Size: 8, Stroke: 25mm, Action: D (Double Acting), Rod End Thread: M (Rod End Male Thread), Auto Switch: F8B--Solid State, Gen Purpose, 2 Wire, Vertical, Lead Wire or Prewired Connector: L (3m)
Magnet: D (Built-in Magnet), Mounting Direction: B (Lateral Mounting), Bore Size: 8, Stroke: 25mm, Action: D (Double Acting), Rod End Thread: Rod End Female Thread (w/o Thread for ø4), Auto Switch: F8B--Solid State, Gen Purpose, 2 Wire, Vertical, Lead Wire or Prewired Connector: L (3m)
Magnet: D (Built-in Magnet), Mounting Direction: B (Lateral Mounting), Bore Size: 8, Stroke: 8mm, Action: D (Double Acting), Rod End Thread: M (Rod End Male Thread), Auto Switch: F8B--Solid State, Gen Purpose, 2 Wire, Vertical, Lead Wire or Prewired Connector: L (3m)
Magnet: D (Built-in Magnet), Mounting Direction: B (Lateral Mounting), Bore Size: 8, Stroke: 30mm, Action: D (Double Acting), Rod End Thread: M (Rod End Male Thread), Auto Switch: F8B--Solid State, Gen Purpose, 2 Wire, Vertical, Lead Wire or Prewired Connector: L (3m)
Magnet: D (Built-in Magnet), Mounting Direction: B (Lateral Mounting), Bore Size: 8, Stroke: 4mm, Action: D (Double Acting), Rod End Thread: Rod End Female Thread (w/o Thread for ø4), Auto Switch: F8B--Solid State, Gen Purpose, 2 Wire, Vertical, Lead Wire or Prewired Connector: L (3m)