Magnet: Built-in, Type: Pneumatic, Mounting: Axial Foot, Bore: 25mm, Port Thread: NPT, Stroke: 125mm, Cushion: Rubber Bumper, Rod End Thread: Male Rod End, Rod Boot: None, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Leadwire or Prewired Connector: -, Number: -
Magnet: Built-in, Type: Pneumatic, Mounting: Axial Foot, Bore: 25mm, Port Thread: NPT, Stroke: 25mm, Cushion: Air Cushion, Rod End Thread: Male Rod End, Rod Boot: None, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Leadwire or Prewired Connector: -, Number: -
Base gasket (for metal base and sub-plate) SY70M-11-1A SY50M-11-1A SY30M-11-1A w plug-in VZ1000-11-4VZ1000-11-4VZ1000-11-1e Refer to page 239. DIN rail Clamp bracket assembly (for metal base) Part numbers shown on the left are for the clamp bracket assembly for one manifold (two sets of clamp brackets).
70 170 69 70 95 87 11 3 100 88 196 96 83 110 114 11 3 117 90 235 131 102 130 134 11 3 154 108 300 112 153 180 190 11 3 200 138 315 Note 1) Dimension E applies when heater option is included.
0 0.036 0 0.043 0 0.043 +0.025 0 +0.025 0 +0.030 0 +0.030 0 +0.036 0 12 14 17 23 31.5 8 10 11 15 21.5 2H9 8h9 6 7 9 11 12 3H9 8h9 4H9 10h9 6H9 12h9 8H9 14h9 TA M4 x 0.7 M4 x 0.7 M5 x 0.8 M5 x 0.8 M6 x 1 SC 9 9 12 14 19 SB 8 9.5 9.5 11 11 R 44 53 62 76 95 SA 4.5 5.5 5.5 6.6 6.6 Y O 4.5 4.5 5 5.5 6 P M5 x 0.8 M5 x 0.8 M5 x 0.8 M5 x 0.8 Rc 1/8 Q 11 12 14 17 20 TB 8 8 10 10 12 UA M4 x 0.7 M5
6.5 9.5 11 15.5 14.5 15 12 8 12 9.5 11 10 8.5 13 10.5 12 9.5 10 9.5 13.5 11 13 10 10.5 9.5 14.5 12.5 14 11 9.5 10 14.5 13 14 11 9.5 11 15.5 14.5 15 12 8 12 9.5 11 10 8.5 13 10.5 12 9.5 10 9.5 13.5 11 13 10 10.5 9.5 14.5 12.5 14 11 CH2F (mm) Auto switch model Bore size (mm) 32 40 50 63 80 100 D-M9m/M9mV D-M9mW/M9mWV D-M9mAL/M9mAVL D-F5m/J5m/F59F D-F5mW/J59W D-F5BAL/F5NTL D-G5m
70 170 69 70 95 87 11 3 100 88 196 96 83 110 114 11 3 117 90 235 131 102 130 134 11 3 154 108 300 112 153 180 190 11 3 200 138 315 Note 1) Dimension E applies when heater option is included.
11 99 116 134 20 77 45.5 53.5 73.5 80 56 43.5 18 1/2-13UNC M12 x 1.75 10 35.5 100 53.5 11 11 117 136 154 22 94 50.5 63 85 100 64 43.5 22 1/2-13UNC M12 x 1.75 12 40.5 Flange bracket material: Carbon steel For details about the rod end nut and accessory brackets, refer to page 178.
Set the mounting band perpendicularly to cylinder tube. 20 50 63 80 100 25 32 40 D-B7/B80 8 10 9 10 10 11 D-B73C/B80C D-C7/C80 8 10 9 10 10 11 D-C73C/C80C 8 10 9 10 10 11 D-B5/B64 11 11 MX Mounting correctly Mounting incorrectly 13 13 14 14 14 17 D-B59W 18 16 D-G79/K79 8 10 9 10 10 11 Auto Switch Mounting Bracket Part No.
M4 x 0.7 21 10 GKM4-8 4 8 16 4 8 8 11 M4 x 0.7 21 12 GKM6-12 6 12 24 6 12 10 18 M6 x 1 31 16 GKM6-12 6 12 24 6 12 10 18 M6 x 1 31 20 GKM8-16 8 16 32 8 16 14 23 M8 x 1.25 42 25 GKM10-20 10 20 40 10 20 18 27 M10 x 1.25 52 Bore size Part no. b1 b3 dH7 d6 d7 h l l3 d3 a 8 KJ4D 8 6.0 5 18 11 27 10 10 M4 x 0.7 13 10 KJ4D 8 6.0 5 18 11 27 10 10 M4 x 0.7 13 12 KJ6D 9 6.75 6 20 13 30 12 11 M6 x 1
D-C7 D-C80 10 15 50 50 + 45 (n2) D-B5/B64 8 10 13 4 8.5 9 14 4.5 9 10 14 5 10 10 14 6 9.5 11 17 6.5 10.5 11 16 6.5 10.5 11 18 7 11 9 10 9 10 10 11 11 11 9 10 10 11 RZQ 15 + 45 ( ) n2 2 D-H7 D-H7W D-H7BAL D-H7NF D-B59W 13 (n = 2, 4, 6, ) D-H7/H7NF/H7W/H7BAL 4 10 15 60 60 + 45 (n2) MI W S D-H7C 7 D-A3/A44 D-G39/K39 8 CEP1 D-C73C D-C80C D-H7C 10 15 65 9 9 9 15 + 50 ( ) n2 2 65 + 50 (n2) D-G5
D-M9P D-M9NV D-M9B D-M9N D-M9PV D-M9BV Auto switch part no.
Bore size (mm) Stroke range (mm) 20 25 32 40 50 63 80 100 A AL B1 C D E F GA GB H H1 I J K KA MM NA P S TA TB ZZ 114 119 121 139 162 162 196 196 11 11 11 12 13 13 12 12 12 13 14 14 20 20 35 40 40 50 58 58 71 71 5 6 6 8 11 11 13 16 26 31 38 47 58 72 89 110 5 M8 x 1.25 24 1/8 1/8 1/8 1/8 1/4 1/4 3/8 1/2 77 77 79 87 102 102 122 122 11 11 11 12 13 13 12 12 12 13 14 14 20 20 Up to 350 Up to
Load voltage Auto switch model Lead wire length [m] Pre-wired connector Applicable load DC AC Band mounting Rail mounting 0.5 (Nil) 1 (M) 3 (L) 5 (Z) None (N) Perpendicular In-line Perpendicular In-line Indicator light Type Special function Electrical entry Wiring (Output) M9NV M9N M9NV M9N V V V v v IC circuit 3-wire (NPN) 5 V,12 V 3-wire (PNP) M9PV M9P M9PV M9P V V V v v Grommet Solid
11 99 134 20 53.5 77 100 100 64 12 43.5 M12 x 1.75 22 85 63 117 136 11 11 154 22 53.5 94 For details about the rod end nut and accessory brackets, refer to page 19.
9.5 11 27 9.5 1.5 0 32 0.5 11 9.5 2.5 Note 1) [ ]: Denotes the values of D-A93.
Main circuit of switch OUT Black Mass (g) DC () Blue D-Y7NW(V) D-Y7PW(V) D-Y7BW(V) Auto switch model 11 11 11 0.5 D-Y7PW, Y7PWV Lead wire length (m) 54 54 54 3 DC (+) Brown 88 88 88 5 Main circuit of switch Main circuit of switch Dimensions (mm) OUT Black D-Y7W M2.5 x 4 L Slotted set screw Indicator light DC () Blue 3.4 2.5 SMC SMC 6.2 5 D-Y7BW, Y7BWV 29 OUT (+) Brown Most sensitive position
Series 10-/11-/21-/22-CDG1 Series 10-/11-REC Series 10-/11-CDM2X Series Perpendicular entry is unavailable.
11 11 13 13 13 14 14 15 9 9 10 11 11 11 D-Y59/Y69 D-Y7P/Y7V D-Y7W/Y7WV D-Y7BAL 5.5 5.5 7 7.5 6.5 5.5 D-F5/J5 D-F5W/J59W D-F5BAL/F5NTL D-F59F 3.5 4 4 4.5 4.5 4.5 DD-G39/K39 D-P4DWL 9 9 10 11 11 11 -X 4 4 4 4.5 4 4.5 Since this is a guideline including hysteresis, not meant to be guaranteed.