SMC Corporation of America
Elite Part Number Search
Search Results "10-CDUJB10-15D-F8NL"

Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Plate Cylinder, Additional Function: Standard, Environment, Applications: Clean Room, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1 to 0.7, Specification: Built-in magnet

Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Plate Cylinder, Additional Function: Standard, Environment, Applications: Clean Room, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1 to 0.7, Specification: Built-in magnet

Clean Room: 10 (Relief Type), Magnet: D (Built-in), Mounting Direction: B (Lateral Mounting), Bore: 6mm, Stroke: 15mm, Rod End Thread: Rod End Female Thread, Auto Switch: F8N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: L (3m)

Clean Room: 10 (Relief Type), Magnet: D (Built-in), Mounting Direction: B (Lateral Mounting), Bore: 8mm, Stroke: 15mm, Rod End Thread: Rod End Female Thread, Auto Switch: F8N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: L (3m)

Clean Room: Relief Type, Magnet: Built-in, Mounting Direction: Lateral Mounting, Bore: 6mm, Stroke: 15mm, Rod End Thread: Rod End Female Thread, Auto Switch: F8N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -

Clean Room: Relief Type, Magnet: Built-in, Mounting Direction: Lateral Mounting, Bore: 8mm, Stroke: 15mm, Rod End Thread: Rod End Female Thread, Auto Switch: F8N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -

No freezing (for cylinders with or without an auto switch) Bore Size/Standard Stroke Symbol Specifications (mm) XA Change of rod end shape Rod end configuration XC3 Special port location Bore size (mm) Round bar, Chamfered type Roller type Lever type with shock absorber 12 10 10 16 10, 15 10, 15 20 10, 15, 20 10, 15, 20 32 10, 15, 20 40 Spring Force (Single acting) 20, 25, 30 20, 25, 30

SMC SMC Pitch = 21 20 10 10 10 Manual override (Simply turn the locking type override.) L3 L2 L1 4 10 Vacuum switch ZSE2 8 Pressure setting trimmer 15 (Needle fully open) Filter Body (Air operated type) (ZX1A) 18 Adapter B M5 Pilot port 9.3 (44) M5 External release port 13 22 35 37.4 45.4 Adapter D 58.3 Individual spacer ZX1-R1 Release valve VJ314 Pilot valve for supply (N.C.)

, 20, 30, 40, 50 10, 20, 30, 40, 50, 75 10, 20, 30, 40, 50, 75, 100 10, 20, 30, 40, 50, 75, 100, 125 10, 20, 30, 40, 50, 75, 100, 125, 150 10, 20, 30, 40, 50,7 5, 100, 125, 150 *90and 91-series MXQ6 products do not have shock absorbers.

-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Vacuum switch unit E C ZX1 1 10 Ejector unit Filter unit F ZX1 1 10 Ejector unit PV/V port size Ejector unit nozzle dia.

, 13, 15 For nozzle size 18, 20 For nozzle size 10, 13, 15 For nozzle size 18, 20 e r t For nozzle size 10, 13, 15 [For ZSE4 spec.]

Magnet: D (Built-in Magnet), Mounting Direction: B (Lateral Mounting), Bore Size: 10, Stroke: 10mm, Action: D (Double Acting), Rod End Thread: Rod End Female Thread (w/o Thread for ø4), Auto Switch: F8N--Solid State, Gen Purpose, 3 Wire NPN, Vertical, Lead Wire or Prewired Connector: L (3m)

Magnet: D (Built-in Magnet), Mounting Direction: B (Lateral Mounting), Bore Size: 10, Stroke: 15mm, Action: D (Double Acting), Rod End Thread: M (Rod End Male Thread), Auto Switch: F8N--Solid State, Gen Purpose, 3 Wire NPN, Vertical, Lead Wire or Prewired Connector: L (3m)

Magnet: D (Built-in Magnet), Mounting Direction: B (Lateral Mounting), Bore Size: 10, Stroke: 20mm, Action: D (Double Acting), Rod End Thread: Rod End Female Thread (w/o Thread for ø4), Auto Switch: F8N--Solid State, Gen Purpose, 3 Wire NPN, Vertical, Lead Wire or Prewired Connector: L (3m)

Magnet: D (Built-in Magnet), Mounting Direction: B (Lateral Mounting), Bore Size: 10, Stroke: 20mm, Action: D (Double Acting), Rod End Thread: M (Rod End Male Thread), Auto Switch: F8N--Solid State, Gen Purpose, 3 Wire NPN, Vertical, Lead Wire or Prewired Connector: L (3m)

Magnet: D (Built-in Magnet), Mounting Direction: B (Lateral Mounting), Bore Size: 10, Stroke: 4mm, Action: D (Double Acting), Rod End Thread: Rod End Female Thread (w/o Thread for ø4), Auto Switch: F8N--Solid State, Gen Purpose, 3 Wire NPN, Vertical, Lead Wire or Prewired Connector: L (3m)

Magnet: D (Built-in Magnet), Mounting Direction: B (Lateral Mounting), Bore Size: 10, Stroke: 8mm, Action: D (Double Acting), Rod End Thread: Rod End Female Thread (w/o Thread for ø4), Auto Switch: F8N--Solid State, Gen Purpose, 3 Wire NPN, Vertical, Lead Wire or Prewired Connector: L (3m)

Magnet: D (Built-in Magnet), Mounting Direction: B (Lateral Mounting), Bore Size: 10, Stroke: 6mm, Action: D (Double Acting), Rod End Thread: Rod End Female Thread (w/o Thread for ø4), Auto Switch: F8N--Solid State, Gen Purpose, 3 Wire NPN, Vertical, Lead Wire or Prewired Connector: L (3m)

Magnet: D (Built-in Magnet), Mounting Direction: B (Lateral Mounting), Bore Size: 10, Stroke: 6mm, Action: S (Single Acting Spring Return), Rod End Thread: Rod End Female Thread (w/o Thread for ø4), Auto Switch: F8N--Solid State, Gen Purpose, 3 Wire NPN, Vertical, Lead Wire or Prewired Connector: L (3m)