8 (left side) One-touch fitting 10 (left side) Mixed 02R 03R 02L 03L 02Y 03Y C6R C8R C10R C6L C8L C10L Control equipment Symbol Nil A AP M MP F G C E Air filter with auto drain 10 stations 10 Air filter with manual drain Note) When equipped with control unit, one or two stations are used for mounting.
10 stations Size of P, EA, EB port Note) SU and TBU require one station. 02 03 04 06 10 1/4 3/8 1/2 3/4 1 Location and size of A, B port 02 03 04 06 10 02B 03B 04B Side 1/4 Side 3/8 Side 1/2 Side 3/4 SIde 1 Bottom 1/4 Bottom 3/8 Bottom 1/2 Option Nil TBU SU W None With terminal box With SI unit Splash proof 3-11-18
VY1 How to Order G PPA Internal pilot operated relieving type regulator AR 25 4 BG R 02 Option Nil Flow direction: Right Left AL None Regulator R Body size Accessory 4 6 8 9 1 2 1 Symbol Description Applicable model Port size 1 Nil 1 4 02 03 04 06 10 12 14 20 2 1 With bracket AR45 to 65 AR25 AR35 B 8 3 2 G46-10-02 G46-2-02 Gauge 1 2 3 4 G Regulating pressure range Pressure gauges are shipped
x 0.8 12 10 12 10 1 (P) 3 (R) 1 (P) XT34 Poppet VM200 2 port 3 port (A) 2 (A) 2 Side ported 1/4 Page 337 12 12 10 10 1 (P) 3 (R) 1 (P) VM400 3 port (OUT) 2 3 10 12 1 (N.C.)
, IDF6E-10 IDF8E-10, IDF11E-10 Type 100 V 10 A IDU3E-10, IDU4E-10 IDU6E-10 30 mA IDF4E-20, IDF6E-20 IDF8E-20, IDF11E-20 Type 200 V 5 A IDU3E-20, IDU4E-20 IDU6E-20 S Option symbol IDF1E-10 to 11E-10, IDU3E-10 to IDU6E-10 With power cord connection The option allows the connection of a power cord to a terminal block.
G46-10-01 2 pcs. G46-10-01 2 pcs. G27-10-R1-X209 2 pcs. G27-10-R1-X209 2 pcs.
G27-10-R1-X2092pcs. G46-10-012pcs. G27-10-R1-X2092pcs. G46-10-012pcs.
0 10 20 30 40 50 60 50 60 40 30 20 10 0 10 20 30 Atmospheric pressure dew point ( C) 14-19-10 7 Membrane Air Dryer Series IDG Calculation of inlet air flow rate Q1, and confirmation of compressed air supply capacity.
Model Optional specifications AW10(K) AW20P-270AS AR20P-260S AW20(K) AW30(K) AR40P-270AS AR40P-260S AW40(K) AW40(K)-06 AW60(K) AW60P-270AS Note 6) Bracket assembly Note 1) AR10P-270AS AR10P-260S G27-10-R1 G27-10-R1 Note 3) AR30P-270AS AR30P-260S Note 7) Set nut G36-10-01 G36-2-01 G36-10-01-L G36-2-01-L G46-10-02 G46-2-02 G46-10-02-L G46-2-02-L Round type Note 2) Standard 0.02 to 0.2 MPa
Fluoropolymer Needle Valve Series LVN Specifications LVN20 LVN30 LVN40 Model Orifice diameter 4.4 4, 6 1/8", 3/16", 1/4" Metric Inch 10 10, 12 3/8", 1/2" 8 6, 8, 10 1/4", 3/8" Tube size Refer to Best Pneumatics No. 7 for further details.
Standard dew point -20oC, -15oC : about 10 min.
is D side mounting only. 10 Note) 10 stations Note) Base 01T/10/40: 2 to 10 stations Base 01C/01F: 2 to 8 stations Including stations of control unit.
Rubber seal 45 or less VQ7-8-FG-D3.0 0.24 12 2.4 0.18 10 Metal seal 15 or less 0.70 Double VQ7-8-FG-D-R 3.3 0.27 13 3.0 0.24 12 Rubber seal 20 or less VK VQ7-8-FHG-D2.4 0.24 10 2.4 0.28 10 Metal seal 45 or less Closed center 0.75 VQ7-8-FHG-D-R 2.8 0.27 11 2.8 0.25 11 Rubber seal 50 or less VZ VQ7-8 3/8 VQ7-8-FJG-D2.4 0.20 10 2.4 0.16 10 Metal seal 45 or less Exhaust center 0.75 VF VQ7-8-FJG-D-R
seal 45 or less VQ7-8-FG-D3.0 0.24 12 2.4 0.18 10 Metal seal 15 or less 0.70 Double VQ7-8-FG-D-R 3.3 0.27 13 3.0 0.24 12 Rubber seal 20 or less VK VQ7-8-FHG-D2.4 0.24 10 2.4 0.28 10 Metal seal 45 or less Closed center 0.75 VQ7-8-FHG-D-R 2.8 0.27 11 2.8 0.25 11 Rubber seal 50 or less VZ VQ7-8 3/8 VQ7-8-FJG-D2.4 0.20 10 2.4 0.16 10 Metal seal 45 or less Exhaust center 0.75 VF VQ7-8-FJG-D-R
Swtting of communication speed (Switch No.8 to 10) Make sure to set the transmission speed in the range as follows. All setting are turned OFF at shipment, set to 156 kbps. Transmission speed No.8 No.9 No.10 156 kbps OFF OFF OFF 625 kbps OFF OFF ON 2.5 Mbps OFF ON OFF 5 Mbps OFF ON ON 10 Mbps ON OFF OFF -21No.EX-OMI0001-I 2.
Terminal No. 2 4 6 8 10 12 14 16 18 20 Output No. 1 3 5 7 9 11 13 15 24 V Type +COM EX510-S102 Terminal No. 1 3 5 7 9 11 13 15 17 19 Output No. 0 2 4 6 8 10 12 14 0 V Type + + + + + + + + -COM Terminal No. 2 4 6 8 10 12 14 16 18 20 Output No. 1 3 5 7 9 11 13 15 0 V Type + + + + + + + + -COM : Only a flat cable type manifold (P kit) can be connected to EX510-S 02 .
Terminal No. 2 4 6 8 10 12 14 16 18 20 Output No. 1 3 5 7 9 11 13 15 24 V Type +COM EX510-S102 Terminal No. 1 3 5 7 9 11 13 15 17 19 Output No. 0 2 4 6 8 10 12 14 0 V Type + + + + + + + + -COM Terminal No. 2 4 6 8 10 12 14 16 18 20 Output No. 1 3 5 7 9 11 13 15 0 V Type + + + + + + + + -COM : Only a flat cable type manifold (P kit) can be connected to EX510-S 02 .
Operating Note 3) 2-position 8-6:5, 8-8:6, 8-10:5 8-6:20, 8-8:15, 8-10:10 frequency cycle/sec. 3-position 8-6:3, 8-8:3, 8-10:2 8-6:10, 8-8:10, 8-10:20 Lubrication Not Required Manual override Non-locking push type Protection structure Dust Proof Coil rated voltage 100VAC, 110VAC, 200VAC, 220VAC, 24VDC Allowable voltage range % -15~ +10% of rated voltage Coil insulation Class B or equivalent
1 Size 3 TU1 Terminal Box Note: Please ask available protocol to SMC Conduit Port Thread (for terminal box only) Symbol Port Thread NIL Rc (PT) F G (PF) N NPT T NPTF Locations and sizes of port 4(A), 2(B) Symbol Port location Applicable ISO size 02 Side 1/4 Size 1 03 Side 3/8 Size 1, 2 04 Side 1/2 Size 1, 2, 3 06 Side 3/4 Size 2, 3 10 Side 1 Size 3 02B Bottom and side 1/4 with plug on