valve with lamp and circuit of protection of surge voltage of 24 VDC 1.5 W (SMC) Connected load Either of the following conditions: Connection error between units has occurred.
Settings1 Intermediate reinforcing brace (EX600-ZMB2) 10 to 57 Hz: constant amplitude 0.75 mm p-p 57 to 150 Hz: constant acceleration 49 m/s2 Mode Diagnostic size set for the input Content 2 Vibration resistance NOTE for 2 hours each in direction X, Y and Z respectively (De-energized) 0 OFF 0 byte Input data only (default setting) 147 m/s2 3 times each in directions of X, Y and Z respectively
Vibration resistance for 2 hours in each direction X, Y and Z respectively (De-energized) Impact resistance 147 m/s2 3 times in each directions of X, Y and Z respectively (De-energized) Standard CE marked (EMC directive / RoHS directive), UL (CSA) Weight 300 g 1: All unused connectors must have a seal cap fitted. -25No.EX-OMX1011 Dimensions -26No.EX-OMX1011 End plate Model Indication and
Vibration resistance for 2 hours in each direction X, Y and Z respectively (De-energized) Impact resistance 147 m/s2 3 times in each directions of X, Y and Z respectively (De-energized) Standard CE/UKCA marked, UL (CSA) Weight 300 g 1: All unused connectors must have a seal cap fitted to maintain IP67 rating. -25No.EX-OMZ0024 Dimensions -26No.EX-OMZ0024 End plate Model Indication and How
Intermediate reinforcing brace (EX600-ZMB1) Output Solenoid valve with surge voltage suppressor of 24 VDC, 1.0 W or less, DC General per output (manufactured by SMC) Settings1 Connected load and output rating Content 1 Hold/Clear/Forced ON Fail safe OFF Output is OFF. (default setting) DIN rail mounting (Not available for SY series valves.
Tightening torque: 0.7 to 0.8 Nm. 10 to 57 Hz: constant amplitude 0.75 mm p-p 57 to 150 Hz: constant acceleration 49 m/s2 : Mode 3 is a function for extension in the future. (not to be used.) Vibration resistance After maintenance is complete, perform appropriate functional inspections. Stop operation if the equipment does not function properly.
Vibration resistance for 2 hours in each direction X, Y and Z respectively (De-energized) Impact resistance 147 m/s2 3 times in each directions of X, Y and Z respectively (De-energized) Standard CE/UKCA marked, UL (CSA) Weight 300 g 1: All unused connectors must have a seal cap fitted to maintain IP67 rating. -24No.EX-OMA1023 Dimensions -25No.EX-OMA1023 End plate Model Indication and How
SI SI SMC PROFINET IO EX245 IO-Link SI IP65 2 2 PROFINET IO EX245-SPN1A(24 V)2(SCRJ)2 EX245-SPN2A(24 V)2(RJ45)2 EX245-SPN3A7/8 (5 )2M12(4 ,,D code)2 32 128 64 IO-Link 32 8 (FSU) C (IRT ) MRP(Media Redundancy Protocol)MRPD(Media Redundancy for Planned Duplication) System redundancy S2 Shared device (PROFIenergy) 1 (EX245-SPN1A) 16A(EX245-SPN1A/EX245-SPN2A)6A(EX245-
Vibration resistance (Green) Flashing BUS IN side : Link, Activity for 2 hours each in direction X, Y and Z respectively (De-energized) OFF BUS OUT side: No Link, No Activity 147 m/s2 3 times each in directions of X, Y and Z respectively (De-energized) Impact resistance ON BUS OUT side: Link, No Activity DIN rail mounting (Not available for SY series valves.
given between FE and all accessible terminals) IEC 61131-2 Insulation resistance Ambient temperature Operation: -10 C to 50 C Storage: -20 C to 60 C Ambient humidity 35% to 85% RH (non-condensing) Atmospheric pressure Operation:80 kPa to 108 kPa (under 2000m) Storage: 66 kPa to 108 kPa (under 3500m) 10 Hz to 57 Hz (constant amplitude) 0.75 mm 57 Hz to 150 Hz (constant acceleration) 49 m/s2
M8-Molex Conversion cable * Either the robot side connector S1 or S2 can be connected.
JMHZ2-16D mm 16 MPa 0.1~0.7 (oC) -10~60 (mm) 0.01 (c.p.m.) 120 32.7 (N) 43.5 (mm) 10 3 4M40.7 8 3.4 8 2 14 - 4-2.3 V114-5LU (oC) -1050( (ms) ON5 OFF4 Hz 20 / m/s2 150/30 V114-5LU L (L) (V) 24 -1010% (W) 0.4 [0.40.1] P .1367 LED 300 15 - 4-3.
Vibration resistance for 2 hours in each direction X, Y and Z respectively (De-energized) Impact resistance 147 m/s2 3 times in each directions of X, Y and Z respectively (De-energized) Standard CE marking, UL (CSA), RoHS Weight 300 g 1: All unused connectors must have a seal cap fitted. -25No.EX-OMS0027 Dimensions -26No.EX-OMS0027 End plate Model Indication and How to Order EX600-ED End
s2 in X, Y, Z directions, 3 times each (De-energized)?
10 to 50C35 to 85%RH (with no condensation)1500 VAC for 1 min. between external terminals and FG10 M or more (500 VDC) between external terminals and FG10 to 150 Hz with a 0.35 mm amplitude or 49 m/s2 in each X, Y, Z direction for 2 hrs (De-energized)98 m/s2 in each X, Y, Z direction, 3 times (De-energized)CE marking, UL (CSA)120 g
10 to 50C35 to 85%RH (with no condensation)1500 VAC for 1 min. between external terminals and FG10 M or more (500 VDC) between external terminals and FG10 to 150 Hz with a 0.35 mm amplitude or 49 m/s2 in each X, Y, Z direction for 2 hrs (De-energized)98 m/s2 in each X, Y, Z direction, 3 times (De-energized)CE marking, UL (CSA)120 g
3C)Lights when ON, OUT1: Green, OUT2: RedIP40Operating/Stored: 35 to 85% RH (with no condensation)1000 VAC for 1 min. between live parts and case50 M or more (at 500 VDC) between live parts and case10 to 150 Hz at the smaller of amplitude 1.5 mm or acceleration 20 m/s2 in X, Y, Z directions for 2 hrs. each (De-energized)100 m/s2 in X, Y, Z directions 3 times each (De-energized)?2% F.S.
3C)Lights when ON, OUT1: Green, OUT2: RedIP40Operating/Stored: 35 to 85% RH (with no condensation)1000 VAC for 1 min. between live parts and case50 M or more (at 500 VDC) between live parts and case10 to 150 Hz at the smaller of amplitude 1.5 mm or acceleration 20 m/s2 in X, Y, Z directions for 2 hrs. each (De-energized)100 m/s2 in X, Y, Z directions 3 times each (De-energized)?2% F.S.
3C)Lights when ON, OUT1: Green, OUT2: RedIP40Operating/Stored: 35 to 85% RH (with no condensation)1000 VAC for 1 min. between live parts and case50 M or more (at 500 VDC) between live parts and case10 to 150 Hz at the smaller of amplitude 1.5 mm or acceleration 20 m/s2 in X, Y, Z directions for 2 hrs. each (De-energized)100 m/s2 in X, Y, Z directions 3 times each (De-energized)?2% F.S.
Lube unit S1 Thread type 1a (without oil OFF) ALDU600 (with panel) S2 Nil Rc NPT Body size (Standard) N 6 9 1B 2B Accessory Port size Float Switch Specifications Symbol Description Nil Bracket Panel 4 3 06 10 12 14 20 Voltage Max. contact capacity Max. operating current Contact point construction Level indication 200 VAC, 200 VDC 50 VA AC, 50 W DC 0.5 A AC, 0.5 A DC 1a, 1b Bottom limit indication