SMC Corporation of America
Elite Part Number Search
Search Results "VFA5420-03T-P"

Interface regulator SMC 1 P 5 3 R2 R1 PE How to Order Applicable interface regulator model Reduced pressure port Solenoid valve model ARBQ4000-00-A-1 A VQ40 (plug-in type) ARBQ4000-00-B-1 B ARBQ4000-00-P-1 P ARBQ4000-00-A-5 A VQ45 (plug lead type) ARBQ4000-00-B-5 B ARBQ4000-00-P-5 P Circuit Diagrams Reduced pressure port: A Reduced pressure port: B Reduced pressure port: P SMC Pneumatics,

P: PTFE F: FKM For VCS30 OR-2380-130P P: PTFE F: FKM For VCS40 OR-2600-180P P: PTFE F: FKM Manifold For VCS20 OR-1400-178P P: PTFE F: FKM OR-2670-178P P: PTFE F: FKM For VCS30, 40 OR-1717-178P When the loosened clip is pulled out in direction using pinchers, etc., the coil can be removed and replaced in direction .

Transfer direction Transfer direction P R Applicable Auto Switches/Refer to pages 941 to 1067 for further information on auto switches.

(The part number has a P suffix.) Metal Stopper Table Extension stroke end Retraction stroke end C D M B B E M P A C F Metal stopper only M G A D A MXQA-A38 Model Adjuster part no.

VANE TYPE SERIES NCRB1BW D I M E N S I O N S W I T H S I D E P O R T S NCRB1_W_-_S R O TA R Y A C T U AT O R D I M E N S I O N S W I T H T O P P O R T S NCRB1_W_-_SE R O TA R Y A C T U AT O R R Q (Depth) Model D G J K L M N P F A B C E Q3 Q1 Q2 90O 180O 270O G2 Tolerance G1 Tolerances (Dimensions in Inches) 5-40UNC 0.14 10-32UNF M3 5/32 3/8 0.04 0.12 NCRB1_W10-_S 0.55 0.20 0.35 0.02 0.20

O-ring Wiring top entry Digital pressure switch (Body only ) Lead wire Specifications 0 to 1 MPa Rated pressure range Output 0.1 to 1 MPa Set pressure range NPN open collector 1.5 MPa Withstand pressure Max. 30 V, 80 mA Residual output voltage 1 V or less 0.01 MPa Set pressure resolution 12 to 24 VDC, Ripple (p-p) 10% or less (with power supply polarity protection) Power supply voltage Brown

resolution is 1048576 [Pulse/rev] P Travel amount per 1 command pulse [m] n1/n2 Pulley ratio *1 Ex.)

resolution is 1048576 [Pulse/rev] P Travel amount per 1 command pulse [m] n1/n2 Pulley ratio *1 Ex.)

Depending on the piping volume (piping length and diameter), if the pressure just before the supply (P) port falls below 0.5MPa, the performance such as vacuum pressure may reduce. Raise the upstream pressure,and the pressure just The pressure just before the supply (P) port is low. before the supply (P) port becomes 0.5MPa.

L1 L3 L2 PE TB N PE L TB PRR ILS THR ILS MC THR MC MC PRR CM C01 MC OLR OLP1 CM OLP2 C11 FM PRS MOV P M C11 FM PRS M P IDF55E-30 IDF75E-30 GFCI R GFCI R GFCI GFCI TB TB PRR PRR THR THR CM CM MC2 MC2 FM FM THP THS THP MC1 MC1 MC2 MC2 PRS1 PRS1 P P PRS2 THR PRR PRS2 THR PRR P P M M CM PRS OLR FM PRS1 PRR MC PRS2 TB MC1 ILS GFCI MC2 THR MOV C01 CM THS OLP1 C11 FM THP OLP2

Communication connectoe key P o w er su p p ly co n n ecto r key Bus adaptor 6 Sw i t ch set t i ng Saf et y I nst ruct i ons f or Set t i ng Turn of f t he pow er suppl y w hi l e set t i ng t he sw i t ch. I f t here i s f orei gn m at t er or w at er dropl et s around t he sw i t ch cover, cl ean i t of f bef ore openi ng t he cover.

P(SUP) P A B A(CYL2) B(CYL1) A B EA EB R1(EXH2) R2(EXH1) R1 R2 (B)2 4(A) (B)2 4(A) (R2)3 1 5(R1) (P) (R2)3 1 5(R1) (P) 3(R2) 1(P) 5(R1) JIS () Z (B)2 (A)4 1:P 2:B 3:R2 4:A 5:R1 1:P(SUP) 2:B(CYL.1) 3:R2(EXH.1) 4:A(CYL.2) 5:R1(EXH.2) 1:P 4:A 2:B 5:R1 3:R2 EZTZDZLZMZ DC24V ) 8 VF1000-OMP0001 VF1000/3000/5000 VF1000/3000/5000 VF1000/3000/5000 VF1000/3000/5000 (VF1000/3000 (VF1000/3000 (VF1000

Contact P/A regarding the bowl assembly supply for PSI and F unit specifications.

A P A 37 37 Q Q C C Pressure gauge mounting bore 1/8 4-R R 4-R 36.8 E 36.8 E R P P D D + + MADE IN JAPAN MADE IN JAPAN Model Port size A B C D E G H I K L M N P Q R AV2000-02-G AV2000-02-GS AV2000-02-D AV2000-02-DZ AV2000-02-Y AV2000-02-YZ AV3000-03-G AV3000-03-GS AV3000-03-D AV3000-03-DZ AV3000-03-Y AV3000-03-YZ AV4000-04-G AV4000-04-GS AV4000-04-D AV4000-04-DZ AV4000-04-Y AV4000-04-YZ AV5000

Command pulse (maximum 225/kpps) P Class 3 ground Ground resistor 100 or less Incremental encoder P Deviation counter clear signal (active high) 2CN PG P Be sure to treat the shielding wire terminals. +12 to 24V Note) 4.7k 13 14 5mA Servo ON 1Ry 0V SV-ON 1Ry ON for servo ON 2Ry Proportional control (P actuation) Reverse drive suppression 15 P-CON 2Ry ON for proportional control N-LS 16 N-OT

Real-time switch output ( ) Unit switching Hysteresis mode Display Real-time flow rate l/min Accumulated flow l ON YES OFF P-1 P-2 GPM gal (US) Real-time flow rate GPM = gal (US)/min "P" Window comparator mode H : Hysteresis Note ) Fixed SI unit (l/min, l, m3 or m3x10) will be set for the type without the unit switching function.

= 10.5 13.3 24 24 16.2 16.2 17 36.7 34 34 B 2 B 2 B 2 B 2 B 2 2 B 2 2 B 2 B B R B 2 PE R 3 3 R 3 R 3 1 P 1 P P 1 P 1 X A 4 A 4 A 4 A 4 A 4 A 4 A 4 A 4 A 4 A 4 4-One-touch fitting [1(P), 3(R) port] Applicable tube O.D.: 8 2-One-touch fitting (X, PE port) Applicable tube O.D.: 6 2n-One-touch fitting [4(A), 2(B) port] Applicable tube O.D.: 4, 6 (L4) Applicable connector: 20 pin MIL type with

SYJ514 With valve 16 4 Multistage Ejector Series ZL Dimensions/Series ZL112 (without Valve) 2-5.4 Mounting hole Scale: 40% Label 50 117 Exhaust with silencer P Standard ZL112 20 V 4.5 166 56 Exhaust port Rc1/2 35 P Port exhaust ZL112P V 14 Vacuum pressure gauge Exhaust with silencer 2-5.4 Mounting hole P With vacuum pressure gauge ZL112-G V Exhaust with silencer Vacuum adapter Rc1/8 2-5.4

Sealant/Gasket seal P.554 P.667 P.554 P.554 M/UNF/R/NPT More space beneath the tube. Easier installation/removal of the tube.

1/2 77 60 17 80 133 168 100 25 to 1000 14.5 M42 x 2 58 42 15 257.5 M14 x 1.5 56 115 52 90 56 86 16 50 41 38 19 3/4 79 72 22 97 146 187 Transaxial foot: CHSDLA PJ + Stroke Y J MM S + Stroke H B 2 x RcP GB GA Air release LY D E V V LH LT X1 X2 K F Y1 Cushion valve G C M Y2 MA ZA + Stroke SS BB LX 4 x CD Z + Stroke A ZZ + Stroke Stroke range Bore size (mm) BB CD E F GA GB H M J LH LT LX LY P