, 200, 220VAC , Response time (0.5MPa) w/o indicator light andamp; surge voltage suppressor: 32ms or less , Ambient andamp; fluid temperature: 50 C, VALVE, SGL SOL, BODY PT, *LQA, VALVE, SY7000 SOL/VALVE, RUBBER SEAL, FD, SY7000 BODY PT 1/4, 0.275 lb
, 200, 220VAC , Response time (0.5MPa) w/o indicator light andamp; surge voltage suppressor: 32ms or less , Ambient andamp; fluid temperature: 50 C, VALVE, DBL SOL, BODY PT (AC), VALVE, SY7000 SOL/VALVE, RUBBER SEAL, UE, SY7000 BUILT IN FITTING LESS THAN 1/4, 0.2662 lb
, 200, 220VAC , Response time (0.5MPa) w/o indicator light andamp; surge voltage suppressor: 32ms or less , Ambient andamp; fluid temperature: 50 C, VALVE, DBL SOL, BODY PT, *LQA, VALVE, SY7000 SOL/VALVE, RUBBER SEAL, EE, SY7000 BODY PT 1/4 NPT, 0.308 lb
, 200, 220VAC , Response time (0.5MPa) w/o indicator light andamp; surge voltage suppressor: 32ms or less , Ambient andamp; fluid temperature: 50 C, VALVE, DBL SOL, BODY PT, DIN, VALVE, SY7000 SOL/VALVE, RUBBER SEAL, EF, SY7000 BODY PT 1/4 NPT, 0.49604 lb
, 200, 220VAC , Response time (0.5MPa) w/o indicator light andamp; surge voltage suppressor: 32ms or less , Ambient andamp; fluid temperature: 50 C, VALVE, DBL SOL, BASE MT, DIN, VALVE, SY7000 SOL/VALVE, RUBBER SEAL, 2F, SY7000 NO SIZE RATING, 0.3212 lb
, 200, 220VAC , Response time (0.5MPa) w/o indicator light andamp; surge voltage suppressor: 32ms or less , Ambient andamp; fluid temperature: 50 C, VALVE, DBL SOL, BASE MT, DIN, VALVE, SY7000 SOL/VALVE, RUBBER SEAL, 2G, SY7000 NO SIZE RATING, 0.3476 lb
, 200, 220VAC , Response time (0.5MPa) w/o indicator light andamp; surge voltage suppressor: 32ms or less , Ambient andamp; fluid temperature: 50 C, BLOCKING DISC, VALVE, SY7000 SOL/VALVE, RUBBER SEAL, 21, SY7000 NO SIZE RATING, 0.0077 lb
Fluid: air/inert gas, Operating pressure range: 0.1MPa - 0.7MPa (high pressure: 0.8MPa), Cv factor: 2 position metal seal 0.15; 2 position rubber seal 0.2 3 position metal seal 0.11; 3 position rubber seal 0.15, Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, H 1.5W: 2 position 15 or less; 3 position 25 or less, Ambient and fluid temperature: -10 to
Fluid: air/inert gas, Operating pressure range: 0.1MPa - 0.7MPa (high pressure style 0.8MPa), Effective area mm 2 (Cv): metal seal 3.6 (0.2); rubber seal 5.4 (0.3), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, H 1.5W: 2 position metal seal 12 or less; 2 position rubber seal 15 or less 3 position metal seal 20 or less; 3 position rubber seal 25 or less
Fluid: air/inert gas, Operating pressure range: 0.1MPa - 0.7MPa (high pressure style 0.8MPa), Effective area mm 2 (Cv): metal seal 3.6 (0.2); rubber seal 5.4 (0.3), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, H 1.5W: 2 position metal seal 12 or less; 2 position rubber seal 15 or less 3 position metal seal 20 or less; 3 position rubber seal 25 or less
Fluid: air/inert gas, Operating pressure range: 0.1MPa - 0.7MPa (high pressure style 0.8MPa), Effective area mm 2 (Cv): metal seal 3.6 (0.2); rubber seal 5.4 (0.3), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, H 1.5W: 2 position metal seal 12 or less; 2 position rubber seal 15 or less 3 position metal seal 20 or less; 3 position rubber seal 25 or less
Fluid: air/inert gas, Operating pressure range: 0.1 - 0.7MPa (high pressure type 0.8MPa), Effective area mm 2 (Cv): metal seal: 14.6 (0.81); rubber seal: 16.2 (0.90), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W; H 1.5W: metal seal 22 or less; rubber seal 24 or less, Ambient and fluid temperature: -10 to 50C, VALVE, SGL, FLIP N/PLUG-IN(AC), VALVE,
Fluid: air/inert gas, Operating pressure range: 0.1 - 0.7MPa (high pressure type 0.8MPa), Effective area mm 2 (Cv): 2 position metal seal 14.4 (0.8); 2 position rubber seal 16.2 (0.9) 3 position metal seal 12.6 (0.7); 3 position rubber seal 14.4 (0.8), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, H 1.5W: metal seal 29 or less; rubber seal 34 or less
Fluid: air/inert gas, Operating pressure range: 0.1 - 0.7MPa (high pressure type 0.8MPa), Effective area mm 2 (Cv): 2 position metal seal 14.4 (0.8); 2 position rubber seal 16.2 (0.9) 3 position metal seal 12.6 (0.7); 3 position rubber seal 14.4 (0.8), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, H 1.5W: metal seal 29 or less; rubber seal 34 or less
Fluid: air/inert gas, Operating pressure range: 0.15 - 1.0MPa, Effective area mm 2 (Cv): 2 position metal seal 36.0 (2.0); 2 position rubber seal 39.6 (2.2) 3 position metal seal 19.8 - 36.0 (1.1 - 2.0); 3 position rubber seal 21.6 - 39.6 (1.2 - 2.2), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W: metal seal 12 or less to 55 or less; rubber seal 15 or
Fluid: air/inert gas, Operating pressure range: 0.15 - 1.0MPa, Effective area mm 2 (Cv): 2 position metal seal 36.0 (2.0); 2 position rubber seal 39.6 (2.2) 3 position metal seal 19.8 - 36.0 (1.1 - 2.0); 3 position rubber seal 21.6 - 39.6 (1.2 - 2.2), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W: metal seal 12 or less to 55 or less; rubber seal 15 or
Fluid: air/inert gas, Operating pressure range: 0.15 - 1.0MPa, Effective area mm 2 (Cv): 2 position metal seal 36.0 (2.0); 2 position rubber seal 39.6 (2.2) 3 position metal seal 19.8 - 36.0 (1.1 - 2.0); 3 position rubber seal 21.6 - 39.6 (1.2 - 2.2), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W: metal seal 12 or less to 55 or less; rubber seal 15 or
Fluid: air/inert gas, Operating pressure range: 0.15 - 1.0MPa, Effective area mm 2 (Cv): 2 position metal seal 36.0 (2.0); 2 position rubber seal 39.6 (2.2) 3 position metal seal 19.8 - 36.0 (1.1 - 2.0); 3 position rubber seal 21.6 - 39.6 (1.2 - 2.2), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W: metal seal 12 or less to 55 or less; rubber seal 15 or
Fluid: air/inert gas, Operating pressure range: 0.15 - 1.0MPa, Effective area mm 2 (Cv): 2 position metal seal 36.0 (2.0); 2 position rubber seal 39.6 (2.2) 3 position metal seal 19.8 - 36.0 (1.1 - 2.0); 3 position rubber seal 21.6 - 39.6 (1.2 - 2.2), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W: metal seal 12 or less to 55 or less; rubber seal 15 or
Fluid: air/inert gas, Operating pressure range: 0.10 - 1.0MPa, Effective area mm 2 (Cv): 2 position metal seal 72.0 (4.0); 2 position rubber seal 79.2 (4.4) 3 position metal seal 41.4 (2.3) - 72.0 (4.0); 3 position rubber seal 45.0 (2.5) - 79.2 (4.4), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W: metal seal 20 or less to 62 or less; rubber seal 25 or