The KQ series has been discontinued, please see the New KQ2 series , One-touch fittings, metric size , Connection thread: M, R(PT), Rc(PT) , Body color: black , Release button: blue , Tube material: nylon, soft nylon, polyurethane, FITTING, HALF UNION UNIFIT N/P, CONNECTORS, KQ(UNI) ONE TOUCH UNIFIT, KX, KQ(UNI) 3/8, 0.0418 lb
5% F.S. or less (0 to 50C, based on 25C)Pulse output, N channel, open drain, output for display unit PF2D 300/301(Specifications: Maximum load current of 10 mA; Maximum applied voltage of 30 V)Voltage output Note 5) 1 to 5 VLinearity: ?2% F.S. or less, allowable load resistance: 100 k or moreCurrent output Note 6) 4 to 20 mALinearity: ?
Accepts nylon and urethane tubes, Applicable for both vacuum and positive pressure applications, Release collar allows easy removal of tubing without damaging the tube, Maximum vacuum pressure of 1.0MPa, FTG, MALE RUN TEE UNIFIT N/P, CONNECTORS, KQ2(UNI) ONE TOUCH UNIFIT, GX, 1/4 KQ2(UNI), .03858 lb
Several improvements have been made to the CA2 series including lateral load improvement, increase in cushioning capacity and adoption, INVALID P/N (DISCONTINUED), ACTUATOR, CA1/CA2 TIE-ROD CYLINDER, SC, 100MM CA1 OTHERS (COMBO), 20.9471 lb
Available protocols include Profibus-DP, DeviceNet, CC-Link, Ethernet I/P and EtherCat.Enclosure: IP67(Manifold Assembly), Operating temp. range: -10~50° C, Operating humidity range: 35~85%RH (no dew condensation), Standard: CE marking, UL recognition (CSA), Weight: 290g, "END PLATE, EX, SERIAL TRANSMISSION SYSTEM, N lb
characteristics (1)Response time (ms) (2)Weight (g) 1 4/2 (P A/B)4 5 (A R1)Standard(0.4 W)Quick response(0.95 W) C [dm3/(s?
The KQ series has been discontinued, please see the New KQ2 series , One-touch fittings, metric size , Connection thread: M, R(PT), Rc(PT) , Body color: black , Release button: blue , Tube material: nylon, soft nylon, polyurethane, FITTING, HALF UNION UNIFIT N/P, CONNECTORS, KQ(UNI) ONE TOUCH UNIFIT, DX, KQ(UNI) 5/32, .02200 lb
CG1, double acting, single rod cylinder with made-to-order options, Bores sizes *: 20, 25, 32, 40, 50 63 *, Most options are auto switch capable, Available strokes: 25mm to 1500mm depending on bore size, 7 mounting options, INVALID P/N (STANDARD DEACTIVE, ROUND BODY CYLINDER
The ITV series is IP65 equivalent.Controls air pressure in proportion to an electric signal., Available in MPa, kgf/cm², bar, PSI, and kPa units., Pressure range of 0.005 to 0.9MPa., Available port sizes 1/4 and 3/8., Mounting bracket option., Operation Manual, "REGULATOR, INSTRUMENTATION, IT2000/ITV2000 E/P REGULATOR, DB, IT2000 1/4 INCNPT VERSION, N lb
3% F.S. or less (0 to 50C, based on 25C)Pulse output, N channel, open drain, output for display unit PF2W3 . (Specifications: Maximum load current of 10 mA; Maximum applied voltage of 30 V)Voltage output 1 to 5 VLinearity: ?5% F.S. or less; allowable load resistance: 100 k or more.Current output 4 to 20 mALinearity: ?
3% F.S. or less (0 to 50C, based on 25C)Pulse output, N channel, open drain, output for display unit PF2W3 . (Specifications: Maximum load current of 10 mA; Maximum applied voltage of 30 V)Voltage output 1 to 5 VLinearity: ?5% F.S. or less; allowable load resistance: 100 k or more.Current output 4 to 20 mALinearity: ?
3% F.S. or less (0 to 50C, based on 25C)Pulse output, N channel, open drain, output for display unit PF2W3 . (Specifications: Maximum load current of 10 mA; Maximum applied voltage of 30 V)Voltage output 1 to 5 VLinearity: ?5% F.S. or less; allowable load resistance: 100 k or more.Current output 4 to 20 mALinearity: ?
Please contact us for the latest version.sales@ocaire.com, VALVE, DBL, N/PLUG-IN, VALVE, SQ2000 VALVE, SOL 4-WAY, 1I, SQ2000 OTHER SIZE RATING, .44092 lb, SeriesType of actuationSealModelFlow characteristics (1)Response time (ms) (2)Weight (g) 1 4/2 (P A/B)4/2 5/3 (A/B R1/R2)Standard(0.4 W)Quick response(0.95 W) C [dm3/(s?bar)]bCvC [dm3/(s?
3% F.S. or less (0 to 50C, based on 25C)Pulse output, N channel, open drain, output for display unit PF2W3 . (Specifications: Maximum load current of 10 mA; Maximum applied voltage of 30 V)Voltage output 1 to 5 VLinearity: ?5% F.S. or less; allowable load resistance: 100 k or more.Current output 4 to 20 mALinearity: ?
3% F.S. or less (0 to 50C, based on 25C)Pulse output, N channel, open drain, output for display unit PF2W3 . (Specifications: Maximum load current of 10 mA; Maximum applied voltage of 30 V)Voltage output 1 to 5 VLinearity: ?5% F.S. or less; allowable load resistance: 100 k or more.Current output 4 to 20 mALinearity: ?
3% F.S. or less (0 to 50C, based on 25C)Pulse output, N channel, open drain, output for display unit PF2W3 . (Specifications: Maximum load current of 10 mA; Maximum applied voltage of 30 V)Voltage output 1 to 5 VLinearity: ?5% F.S. or less; allowable load resistance: 100 k or more.Current output 4 to 20 mALinearity: ?
3% F.S. or less (0 to 50C, based on 25C)Pulse output, N channel, open drain, output for display unit PF2W3 . (Specifications: Maximum load current of 10 mA; Maximum applied voltage of 30 V)Voltage output 1 to 5 VLinearity: ?5% F.S. or less; allowable load resistance: 100 k or more.Current output 4 to 20 mALinearity: ?
3% F.S. or less (0 to 50C, based on 25C)Pulse output, N channel, open drain, output for display unit PF2W3 . (Specifications: Maximum load current of 10 mA; Maximum applied voltage of 30 V)Voltage output 1 to 5 VLinearity: ?5% F.S. or less; allowable load resistance: 100 k or more.Current output 4 to 20 mALinearity: ?
Style: Pressure Switch with Piping Adapter, Body Size: 60 (AC50, AC60), Thread Type: N (NPT), Port Size: 06 (3/4), Set Pressure Range: 0.1 to 0.4 MPa, Lead Wire Length: L (3m), Pressure Unit of the Scale Plate: P (MPa/psi Dual Scale), Mounting: Right
Model: 41 (AC), Bar Length: 58 (580mm), Emmiter Cartridge, Material: D (High Speed De-ionizing Cartridge, Tungsten), High-voltage Cable Length: 2 (2m), One-touch Fitting: BH (ø3/8" Straight), Plug Position: R (Opposite Side of High-voltage Cable), Input, Output Specification: P (PNP), Power Supply Cable Length: N (None)